The document describes a digital power meter called the DPM680. It measures various electrical parameters including voltages, currents, power factors, harmonics, energy usage and demand. It has features like a color LCD display, Modbus RTU/TCP communication, built-in web server and waveform display of voltages and currents. It is suitable for monitoring 3-phase 4-wire or 3-wire systems, has IP63 protection and operates from 90-415VAC or 100-300VDC.

Uploaded by

mas zak daniel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
182 views

DPM 680

The document describes a digital power meter called the DPM680. It measures various electrical parameters including voltages, currents, power factors, harmonics, energy usage and demand. It has features like a color LCD display, Modbus RTU/TCP communication, built-in web server and waveform display of voltages and currents. It is suitable for monitoring 3-phase 4-wire or 3-wire systems, has IP63 protection and operates from 90-415VAC or 100-300VDC.

Uploaded by

mas zak daniel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Digital Power Meter

DPM680
Features
Measurement Parameters:
• Phase & Line Voltages (L-N)
• Phase Current & Neutral Current
• Bidirectional kW, kVAR & kVA
• Bidirectional kWh, kVARh & kVAh
• Frequency
• Total & Displacement Power Factor
• Voltage Total Harmonic Distortion
• Current Total Harmonic Distortion
• Thermal Current Demand
• Power Demand
• Current Sequence Components
• Voltage Sequence Components

TFT Colour LCD Display


Serial RS-485 Modbus RTU
Modbus TCP/IP
Built-in Webserver
Voltage & Current Waveform Display
Voltage & Current Harmonics Display

Technical Data
WIRING SYSTEMS POWER & THERMAL CURRENT DEMAND Protocol : Modbus TCP/IP
3-phase 4-wire system Interval : 1 ~ 30 mins Interface : Ethernet 10M/100M BaseT
3-phase 3-wire system
VOLTAGE AND CURRENT SEQUENCE Protocol : HTTP Server
CURRENT MEASUREMENT (TRMS) COMPONENTS Interface : Ethernet 10M/100M BaseT
Nominal current :5A Positive, negative and zero sequence
Min. measurement : 5 mA AUXILIARY POWER SUPPLY
Accuracy : 0.2% of full scale FREQUENCY MEASUREMENT AC voltage : 90 ~ 415 V AC
Burden : < 0.05 VA at 5 A Measurement range : 45 ~ 65 Hz Frequency : 50 / 60 Hz
Measurement range : 10 A Accuracy : 0.2% DC voltage : 100 ~ 300 V DC
Pulsed withstand : 100 A for 1 sec Power consumption : 3W typical
CT primary : 5 ~ 50,000 A ENERGY MEASUREMENT ACCURACY Sustained overload : 500 V AC
Active : IEC 62053-22 class 0.5
VOLTAGE MEASUREMENT (TRMS) Reactive : IEC 62053-23 class 2 ENVIRONMENTAL CONDITIONS
Nominal phase voltage : 0 ~ 300 V AC Overvoltage category : IV
Minimum measurement : 10 V HARMONICS DISPLAY Pollution degree :2
Accuracy : 0.2% at full scale Fundamental up to 32nd order Operating temperature : -10˚C ~ +55˚C
Phase voltage via VT : 60 ~ 50,000 V Storage temperature : -20˚C ~ +70˚C
VOLTAGE & CURRENT WAVEFORM Humidity : 0 – 95%,
DPM 680

POWER MEASUREMENT DISPLAY non condensing


Real power, apparent power, reactive power Simultaneous 3-phase voltage or
Accuracy : 0.5% current waveforms MECHANICAL
Mounting : according to DIN 43700 /
POWER FACTOR MEASUREMENT COMMUNICATION ANSI C39.1
Total and displacement power factor Protocol : Modbus RTU Dimension (mm) : 96(w) x 96(h) x 100(d)
Accuracy : 0.5% Interface : Isolated RS485 Enclosure protection : IP63 at the panel
IP20 at the body
Approximate weight : 0.5 kg
Digital Power Meter

Typical Application Diagrams Case Dimensions


96 mm
3-PHASE 4-WIRE SYSTEM : 4 CTs, Direct V Input 3-PHASE 4-WIRE SYSTEM : 3 CTs, Direct V Input

L1 L2 L3 Ln L1 L2 L3 Ln
90~415 V AC / 90~415 V AC /
AUX 100~300 V DC AUX 100~300 V DC

96 mm
S1
S2
l1
S1
S2
l1 Front
S1
S1
l2 Ethernet l2 Ethernet
S2 S2
S1 S1
l3 l3
S2 S2

S1 S1
ln ln
S2 S2

GND GND
L1 RS 485 L1 RS 485
Modbus-RTU Modbus-RTU
L2 L2

L3 L3
Ln Ln

90 mm
LOAD LOAD

Side

3-PHASE 3-WIRE SYSTEM : 3 CTs, 3 VTs 3-PHASE 3-WIRE SYSTEM : 3 CTs, Direct V Input 83 mm
L1 L2 L3 L1 L2 L3
17 mm

m
0m
90~415 V AC / 90~415 V AC /
AUX 100~300 V DC AUX 100~300 V DC

10
S1 S1
l1 l1
S2 S2
S1 S1
l2 Ethernet l2 Ethernet
S2 S2
S1 S1
l3

86 mm
l3
S2 S2

S1
ln
S1
ln Rear
ea
S2 S2
GND GND
L1 RS 485 L1 RS 485
Modbus-RTU Modbus-RTU
L2 L2

L3 L3
Ln Ln
LOAD GND
LOAD

Test Standards Cut-Out Recommendations

IEC 61010-1
Safety requirements.

91±0.5mm
IEC 61326-1
EMC requirements.

91±0.5mm

Ordering Information 101.6±0.5mm

MODEL DESCRIPTION
DPM 680

DPM 680-415AD Auxiliary Voltage 90 ~ 415 V AC or 100 ~ 300 V DC