ÅP™ Applied Physics, Inc.

Nano Particle Technology


400 N County Road 2 East Cel 720-635-3931
Monte Vista, CO 81144 USA Email [email protected]
WEB www.AppliedPhysicsUSA.com

CleanRoom Fogger™, Model CRF4


■ NEW – 35 piezo ultrasonic devices producing ≈ 1.25 cubic meters pure fog / minute
■ NEW– Highly visible fog at 170ml / minute fog density and 10-15 feet visible airflows
■ CRF4 offers as much fog as some Liquid Nitrogen Foggers, but 33% less cost
■ Compliant to Pharmaceutical USP 797 Insitu Airflow Analysis
■ Compliant to Semiconductor Cleanroom Guidelines, Federal Standard 209E
■ Compliant to ISO 14644-3, B.7 - Airflow Test and Visualization
■ Compliant to ISO 14644-3, B12 Airflow Recovery, 0.5μm Polystyrene Latex spheres
■ De-Ionized Water or Water for Injection (WFI) to produce a pure fog
■ Video the Airflow Patterns, Pressure Differences, Air Migration and Turbulence
■ Use in Pharmaceutical Sterile Rooms, Barrier Isolators and ISO 1 - 9 suites
■ Startup of the Fogger is < 30 seconds, Refill and Restart, Instant On/Off
■ 45 - 90 minute operation provides up to 56 cubic meters fog to visualize turbulence
■ NEW – Touch Pad Display provides water level feedback
■ NEW – Touch Pad Control to adjust fog volume and airflow velocity
■ NEW – Simple, “Lift and Pour” water drainage
■ Low Water Sensor for Ultrasonic, Transducer Protection
■ * Optional Rolling Carry / Storage Case with Extending Handle
■ * Optional Fog Curtain Wand converts stream fog to a wide visual fog wall
■ * Optional Remote Wireless Control using wireless key FOB
■ * Optional Y Adaptor, T Adaptor, LED Light Contrast, 250mm and 500mm Fog Nozzles

The Clean Room Fogger (CRF4), often referred to as a smoke generator or DI water Fogger, using DI Water or WFI water
(pharmaceutical water for injection) during a typical 45 minute fog cycle. Water is converted to fog at about 170ml / minute, producing
≈ 1.25 cubic meters of fog / minute and 10-15 visible airflow distance to visualize airflow in pharmaceutical ISO suites, sterile rooms,
barrier isolators, compound pharmacies and semiconductor clean rooms. The CRF4 fogger is designed to provide much more fog
volume to visualize airflow, patterns and turbulence with on/off fog control. The fog output is about 68 degree F, providing a visible fog
vapor composed of microscopic DI water droplets (fog) at a nominal 5μm droplet size. 16 Meg Ohm, pure DI water is the typical water
used to produce the pure fog. Distilled water or Water for Injection (WFI) can also be used. The fogger cost is much lower than
ultrapure foggers, yet offers as much fog as the lower volume, LN2 foggers. The CRF4 fogger uses 35 ultrasonic transducers
converting over 170ml water to fog per minute, providing the highest fog density, and the very best visible airflow of any ultrasonic
fogger produced in the world. A Low Water sensor protects the transducers during operation. The display provides water fill level, and
the touch pad control allows airflow volume to be adjusted, as well as fog volume produced. The CRF4 fogger enclosure is stainless
steel to provide a sturdy external design; while providing water cooling for the internal ultrasonic transducers, and also provides quick,
easy wipe down of the fogger after use. A Handle is provided to lift the fogger and help the user when draining water at completion of
fog task.

A standard power supply is provided at 110VAC, or 220VAC can be ordered. A flexible, transparent, 5 Meter fog hose is provided.
Several useful options are provided, such as Fog Curtain Wand to create a wide fog curtain pattern. A Wireless Remote Control is
available to place the fogger in a closed clean room or sterile room to operate the fogger remotely from the other side of the wall. The
Rolling Carry/Storage Case is useful for parts storage as well as transport. Semiconductor Cleanroom or Pharmaceutical ISO Suite,
Sterile Room or Medical Room use. Y Adaptor allows two fog outputs, while the T adaptor allows for extra wide fog curtain wand. The
LED Light Boost provides superb contrast between the fore ground of fog and the background clean room.

Rolling Y Adaptor T Adaptor LED.Boost 5 Meter 250mm or 1.3 M and Remote


Carry (Requires (Requires Fog Contrast Fog 500mm 2 M Fog Wireless
Storage 2 Hoses) 2 Wands) Light Hose Nozzles Wands Control

ÅP is a trademark of Applied Physics, Inc. All rights reserved. Copyright since 1997.
Bill To: PO Box 186, Monte Vista, CO 81144 USA Ship To: 400 N County Road 2E, Monte Vista, CO 81144 USA

(ES) Equipements Scientifiques SA - Département Bio-tests & Industries - 127 rue de Buzenval BP 26 - 92380 Garches
Tél. 01 47 95 99 90 - Fax. 01 47 01 16 22 - e-mail: [email protected] - Site Web: www.es-france.com
ÅP™ Applied Physics, Inc. Nano Particle Technology
400 N County Road 2 East Cel 720-635-3931
Monte Vista, CO 81144 USA Email [email protected]
WEB www.AppliedPhysicsUSA.com

Fogger Performance Comparisons


Visual
Fog Fog Liquids Standard Other
Model Fog Density Fog Duration Airflow Where Used
Purity Volume Used Power Power
Distance
LN2 +
DI
AP35 ≈ 5 cubic ≈ 20 - 30 Water for mid sized clean
Ultra 220 VAC,
Ultrapure meters / ≈ 533 ml / minute ≈ 75 minutes feet visual or rooms, sterile rooms 115 VAC
Pure 100VAC
Fogger minute airflow LN2 + and ISO suites
WFI
Water

LN2 +
DI
≈ 15.5
AP100 ≈ 30 – 40 Water for large clean
Ultra cubic 220 VAC,
Ultrapure ≈1520 ml / minute ≈ 75 minutes feet visual or rooms, sterile rooms 115 VAC
Pure meters / 100VAC
Fogger airflow LN2 + and ISO suites
minute
WFI
Water

#1: ≈ 1.5
cubic LN2 +
#1: ≈ 10 -15
meters / #1: ≈ 250ml per DI
feet visual
Other min minute #1: ≈ 45 Minutes Water for mid sized clean
Ultra airflow 220 VAC,
Ultrapure or rooms, sterile rooms 115 VAC
Pure #2: ≈ 1 #2: ≈ 125ml per #2: ≈ 25 Minutes 100VAC
Foggers #2: ≈ 10 feet LN2 + and ISO suites
cubic minute
visual airflow WFI
meter /
Water
min

DI for mid sized clean


≈ 1.25 ≈ 170 ml / minute at ≈ 45 minutes at max
CRF4 ≈ 10 - 15 Water rooms, sterile rooms
cubic max fog volume; and fog volume; and ≈ 90 220 VAC,
Cleanroom Pure feet visual or and ISO suites, 115 VAC
meters / 57 ml / minute at low minutes at low fog 100VAC
Fogger airflow WFI RABs, Barrier
minute fog volume volume
Water Isolators

DI
≈ 0.26 for smaller barrier
CRF2 Water
cubic ≈ 7 - 8 feet isolators, fume 220 VAC,
Cleanroom Pure ≈ 55 ml / minute ≈ 50 minutes or 115 VAC
meters / visual airflow hoods, flow hoods 100VAC
Fogger WFI
minute and glove boxes
Water

DI
≈ 0.20 for smaller barrier
≈ 20 ml / minute, Water
cubic ≈ 6 - 7 feet isolators, fume 220 VAC,
CO2 Fogger CO2 decreasing over fog ≈ 8 – 10 minutes or 115 VAC
meters / visual airflow hoods, flow hoods 100VAC
duration WFI
minute and glove boxes
Water

DI
Portable ≈ 0.10
≈ 3 - 4 feet Water + For industrial clean 220 VAC,
Glycol Glycol cubic meter ≈ 1.0 ml / minute ≈ 45 minutes 115 VAC
visual airflow 90% rooms 100VAC
Fogger / minute
Glycol

ÅP is a trademark of Applied Physics, Inc. All rights reserved. Copyright since 1997.
Bill To: PO Box 186, Monte Vista, CO 81144 USA Ship To: 400 N County Road 2E, Monte Vista, CO 81144 USA

(ES) Equipements Scientifiques SA - Département Bio-tests & Industries - 127 rue de Buzenval BP 26 - 92380 Garches
Tél. 01 47 95 99 90 - Fax. 01 47 01 16 22 - e-mail: [email protected] - Site Web: www.es-france.com

You might also like