Vendor Document / Drawing Front Sheet

Document Title : DATA SHEET FOR TRANSMITTER (INCLUDDIING RTD AND THERMOWELL)

Contractor / Client Doc No. : PGDD-KPE-1472-00-EIC-DS-V41-002 Rev : 0


Vendor Doc No. : YIN-PGDD-IS-005 Rev : C
Area : 1472-00

Location : Dumai Station

System : General

Document Type : Instrument

Discipline : Instrument Sub Discipline : -


 

Submitted For: Proyek Pembangunan Pipa Gas Duri – Dumai


( PGDD )
□ Review □ Certified □ Info
Review does not constitute acceptance of design details, Vendor / Supplier Name:
calculation, test methods or materials developed or selected
by supplier nor does it relieve supplier from full compliance
with contractual or other obligations. PT Yokogawa Indonesia
1. Approved to Proceed (Submit final Package No.: 41
documents in MDR/OM only).
Manufacture may proceed Package Description / Brand :

2. Approved with comments (Revised & Gas Metering Package


resubmit document).
Manufacture may proceed once comment PO No.:
actioned
4110071335
3. Rejected (Revised & Resubmit Work Tag No.:
may not proceed)
02-M-01
4. For Information only (submit Final
Document in MDR/OM only).
Manufacture may proceed

Name :
Date :

Signature :

PT PDC – PT ELNUSA
DATA SHEET FOR TRANSMITTER (INCLUDDIING RTD AND THERMOWELL)
Document No. Rev.
Page 2 of 7
PGDD-KPE-1472-00-EIC-DS-V41-002 0

CLIENT : PT Pertamina Gas

CONTRACTOR : Konsorsium PT Patra Drilling Contractor – PT ELNUSA

PROJECT TITLE : Pembangunan Pipa Gas Duri – Dumai ( PGDD )

0 Issued for Information 18/04/2018 MLF LIE HRL


PRPD CHKD APVD CHKD APVD
REV DESCRIPTION DATE
PT PDC – PT ELNUSA PT PTG PT PTG
DATA SHEET FOR TRANSMITTER (INCLUDDIING RTD AND THERMOWELL)
Document No. Rev.
Page 3 of 7
PGDD-KPE-1472-00-EIC-DS-V41-002 0

REVISION HISTORICAL SHEET

REV DATE DESCRIPTION


DATA SHEET FOR TRANSMITTER (INCLUDDIING RTD AND THERMOWELL)
Document No. Rev.
Page 4 of 7
PGDD-KPE-1472-00-EIC-DS-V41-002 0

TABLE OF CONTENTS

1. Cover Vendor Document ................................................................................... 1


2. Cover Contractor Document ............................................................................. 2
3. Revision Historical Sheet .................................................................................. 3
4. Table of Contents ............................................................................................... 4
5. Data Sheet of Pressure Transmitter ................................................................. 5
6. Data Sheet of Differential Pressure Transmitter ............................................. 6
7. Data Sheet of Temperature Transmitter ........................................................... 7

1. Attachment-1 General Specification of Pressure Transmitter


2. Attachment-2 General Specification of Differential Pressure Transmitter
3. Attachment-3 General Specification of Temperature Transmitter
4. Attachment-4 General Specification of Thermowell
5. Attachment-5 WFC

 
DATA SHEET FOR TRANSMITTER (INCLUDDIING RTD AND THERMOWELL)
Document No. Rev.
Page 5 of 7
PGDD-KPE-1472-00-EIC-DS-V41-002 0
GENERAL 1 Tag Number PIT-001A, PIT-001B
2 Service Export Gas Pressure To Pertamina
3 P&ID No. DUDM-02-PRO-PID-006 SHEET 1 OF 1
4 Design Pressure 690 Psig
5 Design Temp. 150°F
PROCESS 6 Fluid Name Hydrocarbon
CONDITIONS 7 Fluid State Gas/Vapor
8 Pressure Min. Nor. Max. 363 Psig 363 Psig 363 Psig
9 Temperature Min. Nor. Max. 86°F 100°F 100°F
10 Base Pressure 14.73 Psia
11 Base Temperature 60 °F
UNIT 12 Capsule Type Single crystal silicon resonant
13 Transmitter Type Pressure Transmitter
14 Instrument Range Min Max. −14.5 Psig 1450 Psig
15 Zero & Span Adjustment MIn Max. 72.5 Psig 1450 Psig
16 Meter Range MIn Max. 0 Psig 800 Psig
17 Maximum Pressure Limit (psig) 1450
18 Housing Material Cast aluminum alloy with Epoxy and polyurethane resin solvent coating
19 Capsule Material Hastelloy C-276 (Diaphgram); 316L SST (Others)
20 Connection In Size Rating 1/2" NPT M
21 Type Bottom Connection
22 Elec. Haz. Protection STD Method Gr. Temp. II 2G 2D Ex d Ex d IIC T4...T6
23 Weather Protection IP66
24 Sourge Arrester Yes
25 Output Signal 4-20 mA with Hart
26 Power Supply 10.5 to 32 V DC
27 Electrical Connection 1/2" NPT
28 Accuracy ±0.055% of Full Span
29 Stability ±0.1% of URL per 10 years
DIAPHRAGM SEAL 30 Seal Type NA
31 Diaphragm Material NA
32 Flange Material NA
33 Connection Size Rating NA NA
34 Type Facing NA NA
35 Capillary Type Material NA NA
36 Capillary Length NA
OPTIONS 37 Integral Meter Integrated LCD Display
38 Integral Meter Range Min. Max. NA NA
39 Remote Output Gauge Tag No. NA NA
40 Remote Output Gauge Range Min. Max. NA NA
41 Manifold Type Material 2 Way Manifold 316 SS
42 Mounting Brackets Universal Mounting Bracket for 2"-Pipe
43 Upper / Down Burnout Failure Up-scale: 110%, 21.6 mA DC and Down-scale: –5%, 3.2 mA DC
44 Lightning Protector Yes
45 Material 316 Stainless Steel
46 Manifold Type: 2-Way
47 Inlet Connection: 1/2" NPT F
48 Outlet Connection: 1/2" NPT F
Manifold 49 Vent Size (inch): 1/4" NPT F
50 Packing Material: PTFE
51 Maximum Working Pressure (psi): 6000
52 Manufacturer Parker
53 Model HLS2VNC
LINE/VESSEL 54 Number 16"-PG-DM-A02A-026
55 Size Class Sch. 16 inch 300 40
PURCHASE 56 Manufacturer Yokogawa
57 Model EJA530E Series
NOTES:
1. Name Plate shall be included

DATASHEET FOR TRANSMITTER


GAS METERING PACKAGE DUMAI
C IH 18-Apr-18 RE-ISSUED FOR RAPPROVAL
B IH 06-Apr-18 ISSUED FOR RAPPROVAL
PRESURE TRANSMITTER
A IH 23-Mar-18 ISSUED FOR REVIEW
No By Date Revision Doc. No.: YIN-PGDD-IS-005 Sheet 5 of 7 Rev.: C
GENERAL 1 Tag Number DPT-001, DPT-002
2 Service Export Gas Strainer Diff. Pressure
3 P&ID No. DUDM-02-PRO-PID-006 SHEET 1 OF 1
4 Design Pressure 690 Psig
5 Design Temp. 150°F
PROCESS 6 Fluid Name Hydrocarbon
CONDITIONS 7 Fluid State Gas/Vapor
8 Pressure Min. Nor. Max. 363 Psig 363 Psig 363 Psig
9 Temperature Min. Nor. Max. 86°F 100°F 100°F
10 Base Pressure 14.73 Psia
11 Base Temperature 60 °F
UNIT 12 Capsule Type Single crystal silicon resonant
13 Transmitter Type Pressure Transmitter
14 Instrument SPAN Min Max. 0.72 Psig 72 Psig
15 Zero & Span Adjustment MIn Max. -72 Psig 72 Psig
16 Calibration Range MIn Max. 0 Psig 20 Psig
17 Maximum Pressure Limit (psi): 2300
18 Housing Material Cast aluminum alloy with Epoxy and polyurethane resin solvent coating
19 Capsule Material Hastelloy C-276 (Diaphgram); 316L SST (Others)
20 Connection In Size Rating 1/2" NPT F
21 Type Horizontal piping and left side high pressure
22 Elec. Haz. Protection STD Method Gr. Temp. II 2G 2D Ex d Ex d IIC T4...T6
23 Weather Protection IP66
24 Sourge Arrester Yes
25 Output Signal 4-20 mA with Hart
26 Power Supply 10.5 to 32 V DC
27 Electrical Connection 1/2" NPT
28 Accuracy ±0.055% of Full Span
DIAPHRAGM SEAL 29 Seal Type NA
30 Diaphragm Material NA
31 Flange Material NA
32 Connection Size Rating NA NA
33 Type Facing NA NA
34 Capillary Type Material NA NA
35 Capillary Length NA
OPTIONS 36 Integral Meter Integrated LCD Display
37 Integral Meter Range Min. Max. NA NA
38 Remote Output Gauge Tag No. NA NA
39 Remote Output Gauge Range Min. Max. NA NA
40 Manifold Type Material 5 Way Manifold 316 SS
41 Mounting Brackets Universal Mounting Bracket for 2"-Pipe
42 Upper / Down Burnout Failure Up-scale: 110%, 21.6 mA DC and Down-scale: –5%, 3.2 mA DC
43 Lightning Protector Yes
44 Material 316 Stainless Steel
45 Manifold Type: 5-Way Flanged
46 Inlet Connection: 1/2" NPT F
47 Outlet Connection: 1/2" NPT F
Manifold 48 Vent Size (inch): 1/4" NPT F
49 Packing Material: PTFE
50 Maximum Working Pressure (psi): 3600
51 Manufacturer Parker
52 Model HD*5M
LINE/VESSEL 53 Number 16"-PG-DM-A02A-026
54 Size Class Sch. 16 inch 300 40
PURCHASE 55 Manufacturer Yokogawa
56 Model EJA110E Series
NOTES:
1. Name Plate shall be included

DATASHEET FOR TRANSMITTER


GAS METERING PACKAGE DUMAI
C IH 18-Apr-18 RE-ISSUED FOR RAPPROVAL
B IH 06-Apr-18 ISSUED FOR RAPPROVAL
PRESURE TRANSMITTER
A IH 23-Mar-18 ISSUED FOR REVIEW
No By Date Revision Doc. No.: YIN-PGDD-IS-005 Sheet 6 of 7 Rev.: C
GENERAL 1 Tag Number TIT-001A; TIT-001B
2 Service Export Gas Temperature To Pertamina
3 P&ID No. DUDM-02-PRO-PID-006 SHEET 1 OF 1
4 Design Pressure Min. Max. 690 Psig
5 Design Temperature Min. Max. 150°C
PROCESS 6 Fluid Name Hydrocarbon
CONDITIONS 7 Fluid State Gas/Vapor
8 Flow Min. Nor. Max. MMSCFD 57 120 157
9 Press. Min. Nor. Max. Psig 363 363 690
10 Temp. Min. Nor. Max. °F 86 100 100
11 Density @Nor. Flow @Max. Flow lb/ft3 1.2479 (Note2) 1.2480 (Note2) 1.2481 (Note2)
12 Viscosity @Nor. Flow @Max. Flow cP 0.012 0.014
13 MW Min Acid Max Acid 18.6949 18.6949
14 Base Pressure 14.73 Psia
15 Base Temperature 60 °F
ELEMENT 16 Type & Construction RTD
17 Code or Standard IEC 60751
18 Element Material 316 SS
19 Number of Elements Single Input
20 No. of Wires 3 wire
21 Resistance PT 100
22 Temperature range °F 0 200
23 Accuracy Class A
24 Diameter Sheath Material 0.25" (Note 3) 316SS
HEAD / BUILT-IN 25 Elec. Haz. Protection STD Method Gr. Temp. II 2G 2D Ex d II C T4…T6
TRANSMITTER 26 Weather Protection IP67
27 Electric Connection 1/2 " NPT
28 Spring Loading Yes
29 Accuracy ± 0.1% of calibrated span
30 Built-in Transmitter Integral Mounted with LCD Display
31 Output Signal 4-20 mA with Hart
32 Housing Material Cast aluminum alloy with Epoxy and polyurethane resin solvent coating
33 Sourge Arrester Yes
34 Range Min. Max. °F 0 200
35 Calibration Range Min. Max. °F 0 200
36 Integral Meter LCD Display
THERMOWELL 37 Construction Type Collar type
38 Thermowell Material 316 SS
39 Connection In Size Rating 1" ASME 300# RF
40 Flange Material 316 SS
41 Well Material 316 SS
42 Internal Connection Thread 1/2 " NPT
43 U Length 270 mm (Note 5)
44 Plug & Chain Yes
45 Tip thickness 21 mm (Note 5)
46 Nipple and union extension Material 316 SS material
47 size and length size 1/2" NPT, and length is 6"
48 Stamping on thermowell Flange size, Flange Rating, Flange Material, Insertion Length, Well Material, Tag Number
49 Tag Number TW-001A; TW-001B
LINE/VESSEL 50 Number 16"-PG-DM-A02A-026
51 Size Class Sch. 16 INCH 300 40
52 Internal Diameter Line Vessel NA NA
PURCHASE 53 Manufacturer Yokogawa WIKA WIKA
54 Model YTA710 Series Thermowell TW-10 RTD TR10
Notes: Thermowell Drawing
1. Name Plate shall be included
2. Density value as per document PGDD-KPE-14000-00-EPS-DG-001
3. WFC will be provide in document calculation
4. NDE Test (Liquid Penetrant Test For Thermowell)
5. Thermowell dimension:
L: 477 mm Tip Diameter (Y) : 21 mm Bore Diameter : 6.6 mm
U : 270 mm Root Diameter (X) : 21 mm

DATASHEET FOR TRANSMITTER


GAS METERING PACKAGE DUMAI
C IH 18-Apr-18 RE-ISSUED FOR APPROVAL
B IH 06-Apr-18 ISSUED FOR APPROVAL
TEMPERATURE TRANSMITTER
A IH 23-Mar-18 ISSUED FOR APPROVAL
No By Date Description Dwg. No.: YIN-PGDD-IS-005 Sheet 7 of 7 Rev.: C
ATTACHMENT-1

CATALOGUE OF PRESSURE TRANSMITTER


<<Contents>> <<Index>>

General EJA510E and EJA530E


Specifications Absolute and Gauge
Pressure Transmitter
GS 01C31F01-01EN

The high performance absolute and gauge pressure


transmitter EJA510E and EJA530E feature single
crystal silicon resonant sensor and are suitable to
measure liquid, gas, or steam pressure. EJA510E
and EJA530E output a 4 to 20 mA DC signal
corresponding to the measured pressure. It also
features quick response, remote setup and monitoring
via BRAIN or HART communications and self-
diagnostics. FOUNDATION Fieldbus, PROFIBUS PA and
1 to 5 V DC with HART (Low Power) protocol types
are also available.
All EJA-E series models in their standard
configuration, with the exception of the Fieldbus,
PROFIBUS and Low Power types, are certified as
complying with SIL 2 for safety requirement.

 STANDARD SPECIFICATIONS
Refer to GS 01C31T02-01EN for Fieldbus
communication type and GS 01C31T04-01EN for
PROFIBUS PA communication type for the items Specification Conformance
marked with “◊.” EJA-E series ensures specification conformance to at
least ±3σ.
□ SPAN AND RANGE LIMITS Reference Accuracy of Calibrated Span
(includes the effects of terminal-based linearity,
(For EJA510E, values are in absolute and lower
hysteresis, and repeatability)
range limits are 0.)
Measurement Reference Accuracy
Measurement psi bar kg/cm2
MPa span Span≥X Span<X
Span/Range (/D1) (/D3) (/D4)
10 to 200 A
Span 1.45 to 29 0.1 to 2 0.1 to 2
kPa B ±(0.0055 URL/ span)% of Span
A ±0.055%
−100 to −14.5 to
Range −1 to 2 −1 to 2 C of Span
200 kPa 29
14.5 to ±(0.0088 ∗50 MPa/ span)%
Span 0.1 to 2 1 to 20 1 to 20 D
290 of Span
B
−14.5 to
Range −0.1 to 2
290
−1 to 20 −1 to 20 [When /HAC is specified]
72.5 to Reference Accuracy
Span 0.5 to 10 5 to 100 5 to 100 Measurement
1450
C span Span≥X Span<X
−14.5 to
Range −0.1 to 10 −1 to 100 −1 to 100 A ±(0.004 URL/ span)% of Span
1450
720 to B ±(0.005+0.0035 URL/ span) %
Span * 5 to 50 50 to 500 50 to 500 ±0.04%
7200 C of Span
D of Span
−14.5 to
Range * −0.1 to 50 −1 to 500 −1 to 500 ±(0.0064 ∗50 MPa/ span)%
7200 D
of Span
*: Maximum value shall be 70 MPa, 10150 psi,
700 bar or 700 kgf/cm2 respectively when /HG is
specified. Measurement
A B C D
span
□ PERFORMANCE SPECIFICATIONS 20 kPa 0.2 MPa 1 MPa 8 MPa
X
Zero-based calibrated span, linear output, wetted (2.9 psi) (29 psi) (145 psi) (1160 psi)
parts material code ‘S’ and silicone oil, unless URL 200 kPa 2 MPa 10 MPa 50 MPa
otherwise mentioned. (Upper range limit) (29 psi) (290 psi) (1450 psi) (7200 psi)
For Fieldbus and PROFIBUS PA communication
types, use calibrated range instead of span in the
following specifications.

Yokogawa Electric Corporation GS 01C31F01-01EN


2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan ©Copyright June 2012
Tel.: 81-422-52-5690 Fax.: 81-422-52-2018 16th Edition June 2017
<<Contents>> <<Index>> 2
Ambient Temperature Effects per 28°C (50°F) Damping Time Constant (1st order)
Change Amplifier’s damping time constant is adjustable from
±(0.15% of Span + 0.15% of URL) for A, B and C 0.00 to 100.00 s by software and added to response
capsule. time.
±(0.15% of Span + 0.15% of 50 MPa) for D capsule. Note: For BRAIN protocol type, when the software
damping is set to less than 0.5 s, communication
Stability (All normal operating condition) may occasionally be unavailble during the
EJA530E: ±0.1% of URL for 10 years operation, especially while output changes
EJA510E: ±0.2% of URL for 10 years dynamically. The default setting of damping
Power Supply Effects ensures stable communication.
±0.005 % per Volt (from 21.6 to 32 V DC, 350Ω) Update Period “◊”
Vibration Effects Pressure: 45 ms
Amplifier housing code 1 and 3: Zero Adjustment Limits
Less than 0.1% of URL when tested per the Zero can be fully elevated or suppressed, within the
requirements of IEC60770-1 field or pipeline lower and upper range limits of the capsule.
with high vibration level (10-60 Hz, 0.21 mm External Zero Adjustment
displacement/60-2000 Hz 3 g) External zero is continuously adjustable with
Amplifier housing code 2: 0.01% incremental resolution of span. Re-range
Less than ±0.1% of URL when tested per the can be done locally using the digital indicator with
requirements of IEC60770-1 field with general rangesetting switch.
application or pipeline with low vibration level (10-60
Hz 0.15mm displacement /60-500 Hz 2g) Integral Indicator (LCD display, optional) “◊”
5-digit numerical display, 6-digit unit display and bar
Mounting Position Effects graph.
Rotation in diaphragm plane has no effect. Tilting The indicator is configurable to display one or up to
up to 90 degree will cause zero shift up to 0.21 kPa three of the following variables periodically; pressure
(0.84 inH2O) which can be corrected by the zero in %, scaled pressure, measured pressure.
adjustment. See also “Factory Settings.”
Response Time (All capsules) “◊” Local Parameter Setting
90 ms (Output signal code D, J and Q)
When software damping is set to zero and including Parameter configuration by the external zero
dead time of 45 ms (nominal) adjustment screw and push button (Integral indicator
code E) offers easy and quick setup for parameters of
□ FUNCTIONAL SPECIFICATIONS
Tag number, Unit, LRV, URV, Damping, Output mode
Output (linear/square root), Display out 1, and Re-range by
For 4 to 20 mA HART / BRAIN applying actual pressure (LRV/URV).
(Output signal code D and J) Burst Pressure Limits
Two wire 4 to 20 mA DC output with digital A, B and C capsule: 30 MPa
communications, linear or square root programmable. D capsule: 132 MPa
BRAIN or HART FSK protocol are superimposed on
Self Diagnostics
the 4 to 20 mA signal.
CPU failure, hardware failure, configuration error,
Output range: 3.6 mA to 21.6 mA
process alarm for pressure or capsule temperature.
Output limits conforming to NAMUR NE43 can be
User-configurable process high/low alarm for
pre-set by option code C2 or C3.
pressure is also available
For 1 to 5 V HART
Signal Characterizer (Output signal code D, J and Q)
(Output signal code Q)
User-configurable 10-segment signal characterizer
Three or four wire low power 1 to 5 V DC output with
for 4 to 20 mA output.
HART, linear or square root programmable.
HART protocol are superimposed on the 1 to 5 V DC SIL Certification
signal. EJA-E series transmitters except Fieldbus,
Output range: 0.9 V to 5.4 V DC PROFIBUS PA and 1-5V DC with HART(Low Power)
communication types are certified in compliance with
Failure Alarm (Output signal code D and J)
the following standards;
For 4 to 20 mA HART / BRAIN
IEC 61508: 2010; Part1 to Part 7
(Output signal code D and J)
Functional Safety of Electrical/electronic/
Output status at CPU failure and hardware error;
programmable electronic related systems; SIL 2
Up-scale: 110%, 21.6 mA DC or more (standard)
capability for single transmitter use, SIL 3 capability
Down-scale: −5%, 3.2 mA DC or less
for dual transmitter use.
For 1 to 5 V HART
(Output signal code Q) □ NORMAL OPERATING CONDITION
Analog output status at CPU failure and hardware (Optional features or approval codes may
error; affect limits.)
Up-scale: 110%, 5.4 V DC or more (standard)
Down-scale: −5%, 0.8 V DC or less Ambient Temperature Limits
−40 to 85°C (−40 to 185°F)
−30 to 80°C (−22 to 176°F) with LCD display
Process Temperature Limits
−40 to 120°C (−40 to 248°F)

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01C31F01-01EN June 1, 2017-00
<<Contents>> <<Index>> 3
Ambient Humidity Limits
0 to 100% RH
Maximum Over Pressure 100(14.5) Atmospheric
pressure
Working
Pressure pressure
Capsule EJA510E EJA530E kPa abs
A and B 4 MPa abs (580 psia) 4 MPa (580 psig) (psia)
C 20 MPa abs (2900 psia) 20 MPa (2900 psig) Applicable range
D 60 MPa abs (8700 psia) * 60 MPa (8700 psig) *
10(1.4)
*: 105 MPa (15200 psi) when /HG is specified.
Working Pressure Limits (Silicone oil)
Maximum Pressure Limits
2.7(0.38)
Pressure
Capsule EJA510E EJA530E 1(0.14)
A 200 kPa abs (29 psia) 200 kPa (29 psig) -40 0 40 80 120
B 2 MPa abs (290 psia) 2 MPa (290 psig) (-40) (32) (104) (176) (248)
C 10 MPa abs (1450 psia) 10 MPa (1450 psig) Process temperature °C (°F)
D 50 MPa abs (7200 psia) * 50 MPa (7200 psig) *
F02E.ai
*: 70 MPa (10150 psi) when /HG is specified.
Figure 1-2. Working Pressure and Process
Minimum Pressure Limit Temperature [For EJA530E]
See graph below
Supply & Load Requirements
100(750)
(Output signal code D and J. Optional features
or approval codes may affect electrical
requirements.)
With 24 V DC supply, up to a 550Ω load can be
used. See graph below.
10(75)

2.7(20) 600
Working
pressure Applicable range E-10.5
1(7.5) R=
kPa abs External 0.0244 Digital
(mmHg abs) load Communication
resistance range
BRAIN and HART
0.13(1)
0.1(0.75) 250

R (Ω)

0.013(0.1)
0.01(0.075) -40 10.5 16.6 25.2 42
0 40 80 120 (248)
(-40) (32) (104) (176) 85 Power supply voltage E (V DC)
F03E.ai
(185)
Process temperature °C(°F) Figure 2. Relationship Between Power Supply
F01E.ai
Voltage and External Load Resistance
Figure 1-1. Working Pressure and Process (Output signal code D and J)
Temperature [For EJA510E]
Supply Voltage “◊”
For 4 to 20 mA HART / BRAIN
(Output signal code D and J)
10.5 to 42 V DC for general use and flameproof type.
10.5 to 32 V DC for lightning protector
(option code A).
10.5 to 30 V DC for intrinsically safe, type n, non-
incendive or non-sparking type.
Minimum voltage limited at 16.6 V DC for digital
communications, BRAIN and HART

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01C31F01-01EN Oct. 24, 2014-00
<<Contents>> <<Index>> 4
For 1 to 5 V HART □ PHYSICAL SPECIFICATIONS
(Output signal code Q)
Power supply : Wetted Parts Materials
9 to 28 V DC for general use and flame proof type. Diaphragm, process connector
Power Consumption : Refer to “MODEL AND SUFFIX CODES.”
0.96 mA to 3 mA, 27 mW Non-wetted Parts Materials
Load for 4 to 20 mA HART / BRAIN Housing
(Output signal code D and J) • Low copper cast aluminum alloy
0 to 1290Ω for operation • Low copper cast aluminum alloy with corrosion
250 to 600Ω for digital communication resistance properties (copper content ≤ 0.03%,
Output Load for 1 to 5 V HART iron content ≤ 0.15%) (optional)
(Output signal code Q) • ASTM CF-8M Stainless steel (optional)
1 MΩ or greater (meter input impedance) Coating of housing
Note that with three-wire connection, the cable length [for aluminum housing]
may affect the measurement accuracy of the output Urethane curing type polyester resin powder coating
signal. Deep sea moss green paint (Munsell 0.6GY3.1/2.0 or
Communication Requirements “◊” its equivalent)
(Approval codes may affect electrical requirements.) [for option code /P or /X2]
BRAIN Epoxy and polyurethane resin solvent coating
Communication distance Degrees of protection
Up to 2 km (1.25 miles) when using CEV IP66/IP67, Type 4X
polyethylene-insulated PVC-sheathed cables. Pipe
Communication distance varies depending on type of Polypropylene
cable used. Cover O-rings
Load capacitance Buna-N, fluoro-rubber (optional)
0.22 µF or less Name plate and tag
Load inductance 316 SST
3.3 mH or less Fill fluid
Input impedance of communicating device Silicone, Fluorinated oil (optional)
10 kΩ or more at 2.4 kHz. Weight
EMC Conformity Standards Capsule A, B and C: 1.2 kg (2.6 lb)*
EN 61326-1 Class A, Table2 Capsule D: 1.4 kg (3.1 lb)*
EN 61326-2-3 *: Without integral indicator and mounting bracket.
EN 61326-2-5 (for fieldbus) Add 1.5 kg (3.3 lb) for Amplifier housing code 2.
European Pressure Equipment Directive Connections
2014/68/EU Refer to “MODEL AND SUFFIX CODES.”
Sound Engineering Practice (for all capsules)
< Related Instruments>
With option code /PE3 (for D capsule)
FieldMate Versatile Device Management Wizard:
Refer to GS 01R01A01-01E.
Category III, Module H, Type of Equipment: Pressure BRAIN TERMINAL: Refer to GS 01C00A11-00E
Accessory-Vessel, Type of Fluid: Liquid and Gas, Power Distributor: Refer to GS 01B04T01-02E or
Group of Fluid: 1 and 2 GS 01B04T02-02E
EU RoHS Directive
EN 50581 < Reference >
Safety Requirement Standards • is a registered trademark of Yokogawa
EN 61010-1, C22.2 No.61010-1 Electric Corporation.
• Installation category: I • FieldMate; Trademark of Yokogawa Electric
(Anticipated transient overvoltage 330 V) Corporation.
• Pollution degree: 2 • Hastelloy; Trademark of Haynes International Inc.
• Indoor/Outdoor use • HART®: Registered trademark of the FieldComm
Group.
• FOUNDATION Fieldbus; Trademark of the
FieldComm Group.
• PROFIBUS; Registered trademark of Profibus
Nutzerorganisation e.v., Karlsruhe, Germany.
Other company names and product names used in
this material are registered trademarks or trademarks
of their respective owners.

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01C31F01-01EN June 1, 2017-00
<<Contents>> <<Index>> 5
 MODEL AND SUFFIX CODES
Model Suffix Codes Description
EJA510E ............................... Absolute pressure transmitter
EJA530E ............................... Gauge pressure transmitter
Output signal -D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 to 20 mA DC Output with digital communication (BRAIN protocol)
-J . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 to 20 mA DC Output with digital communication
(HART 5/HART 7 protocol)*1
-F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital communication (FOUNDATION Fieldbus protocol, refer to
GS 01C31T02-01EN)
-G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital communication (PROFIBUS PA protocol, refer to
GS 01C31T04-01EN)
-Q . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Low Power, 1 to 5 V DC with digital communication (HART 7 protocol)
Measurement A . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 to 200 kPa (1.45 to 29 psi)
span (capsule) B . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.1 to 2 MPa (14.5 to 290 psi)
C . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 to 10 MPa (72.5 to 1450 psi)
D . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 to 50 MPa (720 to 7200 psi)*10
Wetted parts Process connector Diaphragm Others
material *2 S . . . . . . . . . . . . . . . . . . . . . . . . . 316L SST # Hastelloy C-276 *3# 316L SST #
H . . . . . . . . . . . . . . . . . . . . . . . . . Hastelloy C-276 *3# Hastelloy C-276 *3# Hastelloy C-276 *3#
Process connections 4 . . . . . . . . . . . . . . . . . . . . . . 1/2 NPT female
* For a diaphragm seal 7 . . . . . . . . . . . . . . . . . . . . . . 1/2 NPT male
system, refer to process 8 . . . . . . . . . . . . . . . . . . . . . . G1/2 DIN 16 288 male *4
connections code table 9 . . . . . . . . . . . . . . . . . . . . . . M20×1.5 DIN 16 288 male *4
(p.6).
─ N . . . . . . . . . . . . . . . . . . . Always N
─ -0 . . . . . . . . . . . . . . . . . Always 0
Amplifier housing ► 1 . . . . . . . . . . . . . . Cast aluminum alloy
3 . . . . . . . . . . . . . . Cast aluminum alloy with corrosion resistance properties *5
2 . . . . . . . . . . . . . . ASTM CF-8M stainless steel *6
Electrical connection 0 . . . . . . . . . . . G1/2 female, one electrical connection without blind plugs
► 2 . . . . . . . . . . . 1/2 NPT female, two electrical connections without blind plugs
4 . . . . . . . . . . . M20 female, two electrical connections without blind plugs
5 . . . . . . . . . . . G1/2 female, two electrical connections with a blind plug*7
7 . . . . . . . . . . . 1/2 NPT female, two electrical connections with a blind plug*7
9 . . . . . . . . . . . M20 female, two electrical connections with a blind plug*7
A . . . . . . . . . . . G1/2 female, two electrical connections and a 316 SST blind plug
C . . . . . . . . . . . 1/2 NPT female, two electrical connections and a 316 SST blind plug
D . . . . . . . . . . . M20 female, two electrical connections and a 316 SST blind plug
Integral indicator D . . . . . . . . Digital indicator *8
E . . . . . . . . Digital indicator with the range setting switch (push button) *9
► N . . . . . . . . (None)
Mounting bracket L . . . . . . 316 SST 2-inch pipe mounting
► N . . . . . . None
Optional Codes / Optional specification

The “►” marks indicates the most typical selection for each specification. Example: EJA530E-DAS4N-012NN/.
*1: HART 5 or HART 7 is selectable. Specify upon ordering.
*2: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of
inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage
to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm
and the fill fluid can contaminate the user’s process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium
hypochlorite, and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the
wetted parts material.
*3: Hastelloy C-276 or ASTM N10276.
*4: Not applicable for combination of capsule code D and wetted parts material code H. Threads are based on the withdrawn
DIN 16 288.
*5: Not applicable for electrical connection code 0, 5, 7, 9 and A.
*6: Not applicable for electrical connection code 0, 5, 7 or 9.
*7: Material of a blind plug; aluminum alloy for code 5 and 9, and SUS304 for code 7.
*8: Not applicable for output signal code G.
*9: Not applicable for output signal code F.
*10: 5 to 70 MPa (720 to 10150 psi) when /HG is specified.

The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR0175/ISO 15156.
Please refer to the latest standards for details. Selected materials also conform to NACE MR0103.

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01C31F01-01EN June 1, 2017-00
<<Contents>> <<Index>> 6
[Process Connections Code for Diaphragm Seal System]
Following table shows the code dedicated for EJAC50E Diaphragm Seal System. The code cannot be specified
without a diaphragm seal system. Please also refer to the GS 01C25W01-01EN for EJAC50E.

Process Connections Code Description


P Direct Mount Diaphragm seal system

 OPTIONAL SPECIFICATIONS (For Explosion Protected type) “◊”


For other agency approvals and marine approvals, please refer to GS 01C25A20-01EN.

Item Description Code


Factory Mutual FM Explosionproof Approval *1
(FM) Applicable Standard: FM3600, FM3615, FM3810, ANSI/NEMA 250
Explosionproof for Class I, Division 1, Groups B, C and D, Dust-ignitionproof for Class II/III, Division 1,
FF1
Groups E, F and G, in Hazardous locations, indoors and outdoors (Enclosure: Type 4X)
“FACTORY SEALED, CONDUIT SEAL NOT REQUIRED.”
Temperature class: T6, Amb. Temp.: –40 to 60°C (–40 to 140°F)
FM Intrinsically safe Approval *1*3
Applicable Standard: FM3600, FM3610, FM3611, FM3810
Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1,
Groups E, F & G and Class III, Division 1, Class I, Zone 0, in Hazardous Locations, AEx ia IIC
Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division. 2,
FS1
Groups F & G, Class I, Zone 2, Group IIC, in Hazardous Locations
Enclosure: Type 4X, Temp. Class: T4, Amb. Temp.: –60 to 60°C (–75 to 140°F)
Intrinsically Safe Apparatus Parameters
[Groups A, B, C, D, E, F and G] Vmax=30 V, Imax=200 mA, Pmax=1 W, Ci=6 nF, Li=0 µH
[Groups C, D, E, F and G] Vmax=30 V, Imax=225 mA, Pmax=1 W, Ci=6 nF, Li=0 µH
Combined FF1 and FS1 *1*3 FU1
ATEX ATEX Flameproof Approval *1
Applicable Standard: EN 60079-0:2012+A11:2013, EN 60079-1:2007 (“2014” from August 1, 2017),
EN 60079-31:2014
Certificate: KEMA 07ATEX0109 X
II 2G, 2D Ex d IIC T6...T4 Gb (“Ex db IIC T6...T4 Gb” from August 1, 2017), Ex tb IIIC T85°C Db
Degree of protection: IP66/IP67 KF22
Amb. Temp. (Tamb) for gas-proof :
T4; –50 to 75°C (–58 to 167°F), T5; –50 to 80°C (–58 to 176°F), T6; –50 to 75°C (–58 to 167°F)
Process Temp. for gas-proof (Tp):
T4; –50 to 120°C (–58 to 248°F), T5; –50 to 100°C (–58 to 212°F), T6; –50 to 85°C (–58 to 185°F)
Max. surface Temp. for dust-proof: T85°C (Tamb: –30 to 75°C, Tp: –30 to 85°C) *2
ATEX Intrinsically safe Approval *1*3
Applicable Standard: EN 60079-0:2012+A11:2013, EN 60079-11:2012
Certificate: DEKRA 11ATEX0228 X
II 1G, 2D Ex ia IIC T4 Ga, Ex ia IIIC T85°C T100°C T120°C Db
Degree of protection: IP66/IP67
KS21
Amb. Temp. (Tamb) for EPL Ga: –50 to 60°C (–58 to 140°F)
Maximum Process Temp. (Tp) for EPL Ga:120°C
Electrical data: Ui=30 V, Ii=200 mA, Pi=0.9 W, Ci=27.6 nF, Li=0 µH
Amb. Temp. for EPL Db: –30 to 60°C *2
Max. surface Temp. for EPL Db: T85°C (Tp: 80°C), T100°C (Tp: 100°C), T120°C (Tp: 120°C)
Combined KF22, KS21 and ATEX Intrinsically safe Ex ic *1*3
[ATEX Intrinsically safe Ex ic]
Applicable Standard: EN 60079-0:2012+A11:2013, EN 60079-11:2012 KU22
II 3G Ex ic IIC T4 Gc, Amb. Temp.: –30 to 60°C (–22 to 140°F) *2
Ui=30 V, Ci=27.6 nF, Li=0 μH

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01C31F01-01EN June 1, 2017-00
<<Contents>> <<Index>> 7
Item Description Code
Canadian CSA Explosionproof Approval *1
Standards Certificate: 2014354
Association Applicable Standard: C22.2 No.0, C22.2 No.0.4, C22.2 No.0.5, C22.2 No.25, C22.2 No.30,
(CSA) C22.2 No.94, C22.2 No.60079-0, C22.2 No.60079-1, C22.2 No.61010-1, C22.2 No.61010-2-030
Explosion-proof for Class I, Groups B, C and D.
Dustignition-proof for Class II/III, Groups E, F and G.
When installed in Division 2, “SEAL NOT REQUIRED” Enclosure: Type 4X,
Temp. Code: T6...T4
CF1
Ex d IIC T6...T4 Enclosure: IP66/IP67
Max.Process Temp.: T4;120°C(248°F), T5;100°C(212°F), T6; 85°C(185°F)
Amb.Temp.: –50 to 75°C(–58 to 167°F) for T4, –50 to 80°C(–58 to 176°F) for T5,
–50 to 75°C(–58 to 167°F) for T6 *2
Process Sealing Certification
Dual Seal Certified by CSA to the requirement of ANSI/ISA 12.27.01
No additional sealing required
Primary seal failure annunciation: at the zero adjustment screw
CSA Intrinsically safe Approval *1*3
Certificate: 1606623
[For CSA C22.2]
Applicable Standard: C22.2 No.0, C22.2 No.0.4, C22.2 No.25, C22.2 No.94, C22.2 No.157,
C22.2 No.213, C22.2 No.61010-1, C22.2 No.60079-0, C22.2 No.61010-2-030
Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1, Groups E, F & G,
Class III, Division 1, Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division 2,
Groups F & G, Class III, Division 1
Enclosure: Type 4X, Temp. Code: T4 Amb. Temp.: –50 to 60°C(–58 to 140°F) *2
Electrical Parameters: [Intrinsically Safe] Vmax=30V, Imax=200mA, Pmax=0.9W, Ci=10nF, Li=0 µH
[Nonincendive] Vmax=30V, Ci=10nF, Li=0 µH CS1
[For CSA E60079]
Applicable Standard: CAN/CSA E60079-11, CAN/CSA E60079-15, IEC 60529:2001
Ex ia IIC T4, Ex nL IIC T4 Enclosure: IP66/IP67
Amb. Temp.: –50 to 60°C(–58 to 140°F) *2, Max. Process Temp.: 120°C(248°F)
Electrical Parameters: [Ex ia] Ui=30V, Ii=200mA, Pi=0.9W, Ci=10nF, Li=0 µH
[Ex nL] Ui=30V, Ci=10nF, Li=0 µH
Process Sealing Certification
Dual Seal Certified by CSA to the requirement of ANSI/ISA 12.27.01
No additional sealing required
Primary seal failure annunciation: at the zero adjustment screw
Combined CF1 and CS1 *1*3 CU1
IECEx IECEx Flameproof Approval *1
Applicable Standard: IEC 60079-0:2011, IEC60079-1:2007-4
Certificate: IECEx CSA 07.0008
Flameproof for Zone 1, Ex d IIC T6...T4 Gb Enclosure: IP66/IP67 SF2
Max.Process Temp.: T4;120°C(248°F), T5;100°C(212°F), T6; 85°C(185°F)
Amb.Temp.: –50 to 75°C(–58 to 167°F) for T4, –50 to 80°C(–58 to 176°F) for T5,
–50 to 75°C(–58 to 167°F) for T6
IECEx Intrinsically safe and Flameproof Approval *1*3
Intrinsically safe Ex ia
Certificate: IECEx DEK 11.0081X
Applicable Standard: IEC 60079-0:2011, IEC 60079-11:2011
Ex ia IIC T4 Ga Enclosure: IP66/IP67
Amb. Temp.: –50 to 60 °C(–58 to 140 °F), Max. Process Temp.: 120 °C(248 °F)
Electrical Parameters: Ui=30 V, Ii=200 mA, Pi=0.9 W, Ci=27.6 nF, Li=0 μH
Intrinsically safe Ex ic
Certificate: IECEx DEK 13.0061X
Applicable Standard: IEC 60079-0:2011, IEC 60079-11:2011
SU21
Ex ic IIC T4 Gc IP code: IP66
Amb. Temp.: –30 to 60°C(–22 to 140°F) *2, Max. Process Temp.: 120°C(248°F)
Electrical Parameters: Ui=30V,Ci=27.6 nF, Li=0 μH
Flameproof
Certificate: IECEx CSA 07.0008
Applicable Standard: IEC 60079-0:2011, IEC60079-1:2007-4
Flameproof for Zone 1, Ex d IIC T6...T4 Gb Enclosure: IP66/IP67
Max.Process Temp.: T4;120°C(248°F), T5;100°C(212°F), T6; 85°C(185°F)
Amb.Temp.: –50 to 75°C(–58 to 167°F) for T4, –50 to 80°C(–58 to 176°F) for T5,
–50 to 75°C(–58 to 167°F) for T6
*1: Applicable for Electrical connection code 2, 4, 7, 9, C and D.
*2: Lower limit of ambient temperature is –15°C (5°F) when /HE is specified.
*3: Not applicable for output signal code Q.

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01C31F01-01EN June 1, 2017-00
<<Contents>> <<Index>> 8
 OPTIONAL SPECIFICATIONS
Item Description Code
High accuracy type*16 High accuracy HAC
Painting Color change Amplifier cover only*2 P
Amplifier cover and terminal cover, Munsell 7.5 R4/14 PR
Coating change Anti-corrosion coating*1 X2
316 SST exterior parts 316 SST zero-adjustment screw and setscrews*14 HC
Fluoro-rubber O-ring All O-rings of amplifier housing. Lower limit of ambient temperature: –15°C (5°F) HE
Lightning protector Transmitter power supply voltage: 10.5 to 32 V DC ( 10.5 to 30 V DC for intrinsically safe type,
9 to 32 V DC for Fieldbus communication type.)
A
Allowable current: Max. 6000 A ( 1×40 µs ), Repeating 1000 A ( 1×40 µs ) 100 times
Applicable Standards: IEC 61000-4-4, IEC 61000-4-5
Oil-prohibited use Degrease cleansing treatment K1
Degrease cleansing treatment with fluorinated oilfilled capsule.
K2
Operating temperature −20 to 80°C (−4 to 176°F)
Capsule fill fluid Flourinated oil filled in capsule
K3
Operating temperature −20 to 80°C (−4 to 176°F)
Calibration units*3 P calibration (psi unit) D1
bar calibration (bar unit) (See Table for Span and Range Limits.) D3
M calibration (kgf/cm2 unit) D4
Output limits and failure Failure alarm down-scale : Output status at CPU failure and hardware error is −5%, 3.2mA DC
C1
operation*4 or less for 4 to 20 mA output type and −5%, 0.8V DC or less for 1 to 5 V output type.
Failure alarm down-scale: Output status at CPU
NAMUR NE43 Compliant C2
failure and hardware error is −5%, 3.2 mA DC or less.
Output signal limits:
3.8 mA to 20.5 mA*17 Failure alarm up-scale: Output status at CPU
C3
failure and hardware error is 110%, 21.6 mA or more.
Gold-plated diaphragm*13 Surface of isolating diaphragms are gold plated, effective for hydrogen permeation. A1
Wired tag plate 316 SST tag plate wired onto transmitter N4
Data configuration at factory*5 Software damping, Descriptor,
Data configuration for HART communication type CA
Message
Data configuration for BRAIN communication type Software damping CB
European Pressure PED 2014/68/EU
Equipment Directive*15*16 Category: III, Module: H, Type of Equipment: Pressure Accessory-Vessel, PE3
Type of Fluid: Liquid and Gas, Group of Fluid: 1 and 2
Material certificate*6 Process Connector M15
Pressure test/ Test Pressure: 200 kPa (29 psi) *7 T05
Leak test certificate*12 Test Pressure: 2 MPa (290 psi) *8 T06
Nitrogen(N2) Gas or Water*11
Test Pressure: 10 MPa (1450 psi) *9 T07
Retention time: one minute
Test Pressure: 50 MPa (7200 psi) *10 T08
Test Pressure: 70 MPa (10150 psi)*19 T15
High Pressure-proof
Maximum pressure limit and maximum span : 70 MPa. HG
structure*18
*1: Not applicable with color change option. Not applicable for amplifier housing code 2.
*2: Not applicable for amplifier housing code 2 and 3.
*3: The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specified by option codes D1,
D3, and D4.
*4: Applicable for output signal codes D and J. The hardware error indicates faulty amplifier or capsule.
*5: Also see ‘Ordering Information’.
*6: Material traceability certification, per EN 10204 3.1 B.
*7: Applicable for capsule code A.
*8: Applicable for capsule code B.
*9: Applicable for capsule code C.
*10: Applicable for capsule code D without /HG.
*11: Pure nitrogen gas or pure water is used for oil-prohibited use (option codes K1 and K2).
*12: The unit on the certificate is always kPa/MPa regardless of selection of option code D1, D3 and D4.
*13: Applicable for wetted parts material code S.
*14: 316 or 316L SST. The specification is included in amplifier code 2.
*15: Applicable for measurement span code D. If compliance with category III is needed, specify this option code.
*16: Not applicable for output signal code Q.
*17: The 1 to 5 V voltage output corresponding to 4 to 20 mA current output is applied to output signal code Q which is non-
compliant to NAMUR NE43.
*18: Applicable for capsule code D.
*19: Applicable for capsule code D with /HG specified.

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01C31F01-01EN June 1, 2017-00
<<Contents>> <<Index>> 9
 OPTIONAL SPECIFICATIONS (for Diaphragm Seal System)
Following table shows the option codes dedicated for EJXC50A Diaphragm Seal System. These codes cannot be
specified without a diaphragm seal system. Please also refer to the GS 01C25W01-01EN for EJXC50A.

Item Description Code


Oil-prohibited use Degrease cleansing treatment K11
Degrease cleansing treatment and fluorinated oilfilled capsule.
K12
Operating temperature −20 to 80°C (−4 to 176°F)
Oil-prohibited use with Degrease cleansing and dehydrating treatment K15
dehydrating treatment Degrease cleansing and dehydrating treatment with fluorinated oilfilled capsule.
K16
Operating temperature −20 to 80°C ( −4 to 176°F)
Capsule fill fluid Fluorinated oil filled in capsule
K13
Operating temperature −20 to 80°C (−4 to 176°F)

 DIMENSIONS
Unit: mm (approx.inch)
Model EJA510E and EJA530E

● With process connections code 7

95(3.74) 188(7.40)
60(2.36)*2 Integral indicator Zero
(optional) adjustment 110(4.33)
Extenal indicator 12 39
Conduit connection Conduit connection
(0.47) (1.54)
(optional)

ø78(3.07)

(2.76)
54

ø70
126(4.96)

110(4.33)
(2.13)
159(6.26)

6
(6.50)
165

(0.24)

Ground terminal

Electrical connection
for code 5 and 9. Open to
atmosphere*1

2-inch pipe
Mounting bracket 12*3 (O.D. 60.5 mm) 129(5.08)
(optional) (0.47)

*1: Only for EJA530E whose measurement span code is A, B, or C.


*2: 58 mm (2.28 inch) for measurement span code D.
*3: 11 mm (0.43 inch) for measurement span code D.
*4: When electrical connection code 7 or C is selected, a blind plug is protruded upto 8 mm from the conduit connection.

● With Process connections code 4


(6.14)
156

● With Process connections code 8 and 9


24(0.94)

(6.77)
172

ø6
5(0.20)

(0.24)
F04E.ai

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01C31F01-01EN June 1, 2017-00
<<Contents>> <<Index>> 10

● Terminal Configuration ● Terminal Wiring for 4 to 20 mA output,


FOUNDATION Fieldbus and PROFIBUS PA
communication types
+ 1
Power supply and output terminals
SUPPLY – 2

CHECK + 3
– 2
External indicator (ammeter) terminals*1*2

Ground terminal

*1: When using an external indicator or check meter, the internal


resistance must be 10 Ω or less.
*2: Not available for FOUNDATION Fieldbus and PROFIBUS PA
Terminal 1 Terminal 3 communication types.
Terminal 2
● Terminal Wiring for 1 to 5 V output
+ 1
Power supply terminals
SUPPLY – 2

VOUT + 3 1 to 5 V DC with HART communication


– 2 terminals
Ground terminal

Three or four wire connection. For four wire connection, both supply
and signal lines use SUPPLY - terminal.
F05E.ai

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01C31F01-01EN Oct. 24, 2014-00
<<Contents>> <<Index>> 11

< Ordering Information > “◊” < Factory Setting > “◊”
Specify the following when ordering
Tag number As specified in order
1. Model, suffix codes, and option codes
2. Calibration range and units Software
‘2.00 s’ or as specified in order
1) Calibration range can be specified with range damping *1
value specifications up to 5 digits (excluding any Calibration range
As specified in order
decimal point) for low or high range limits within lower range value
the range of -32000 to 32000. When reverse Calibration range
range is designated, specify Lower Range upper range As specified in order
Value (LRV) as greater than Upper Range Value value
(URV). [EJA530E]
2) Specify only one unit from the table, ‘Factory Selected from mmH2O, mmH2O(68°F),
mmAq*2, mmWG*2, mmHg, Pa, hPa*2,
Settings’ when shipped.’
kPa, MPa, mbar, bar, gf/cm2, kgf/cm2,
3. Display scale and units (for transmitters equipped inH2O, inH2O(68°F), inHg, ftH2O,
with integral indicator only) ftH2O(68°F) or psi. (Only one unit can be
Specify either 0 to 100 % or engineering unit scale specified)
Calibration range
and ‘Range and Unit’ for engineering units scale: units
Scale range can be specified with range limit [EJA510E]
Torr, Pa abs, hPa abs*2, kPa abs,
specifications up to 5 digits (excluding any decimal
MPa abs, mbar abs, bar abs, kgf/cm2 abs,
point) for low or high range limits within the range mmH2O abs, mmH2O abs(68°F),
of -32000 to 32000. The unit display consists of mmHg abs, inH2O abs, inH2O abs(68°F),
6-digit, therefore, if the specified unit is longer than inHg abs, ftH2O abs, ftH2O abs(68°F),
7 characters excluding ‘/’, the first 6 characters will psia, atm.
be displayed on the unit display. Designated value specified in order.
4. HART PROTOCOL Display setting
(%, or user scaled value.)
When output signal code is “J”, specify the HART
protocol revision “5” or “7”. *1: To specify these items at factroy, /CA or /CB
5. TAG NO (if required) option is required.
*2: Not available for HART protocol type.
Specified characters (up to 16 characters for
BRAIN, 22 characters for HART, or 16 characters
for /N4 tag) are engraved on the stainless steel tag < Material Cross Reference >
plate fixed on the housing.
ASTM JIS
6. SOFTWARE TAG (for HART only. if required)
Specified characters (up to 32 characters) are set grade 316 SUS316
as “Tag” (the first 8 characters) and “Long tag”*1 grade 316L SUS316L
(32 characters) in the amplifier memory. Use grade 304 SUS304
alphanumeric capital letters.
When the “SOFTWARE TAG” is not specified,
specified “TAG NO” is set as “Tag” (the first 8
characters) and “Long tag”*1 (22 characters) in the
amplifier memory.
*1: applicable only when HART 7 is selected.
7. Other factory configurations (if required)
Specifying option code CA or CB will allow further
configuration at factory. Following are configurable
items and setting range.
[/CA : For HART communication type]
1) Descriptor (up to 16 characters)
2) Message (up to 30 characters)
3) Software damping in second (0.00 to 100.00)
[/CB : For BRAIN communication type]
1) Software damping in second (0.00 to 100.00)

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01C31F01-01EN June 1, 2017-00
Subject to change without notice.
ATTACHMENT-2
CATALOGUE OF DIFF. PRESSURE
TRANSMITTER
<<Contents>> <<Index>>

General EJA110E
Specifications Differential Pressure Transmitter

GS 01C31B01-01EN

The high performance differential pressure transmitter


EJA110E features single crystal silicon resonant
sensor and is suitable to measure liquid, gas, or
steam flow as well as liquid level, density and
pressure. EJA110E outputs a 4 to 20 mA DC signal
corresponding to the measured differential pressure.
Its accurate and stable sensor can also measure the
static pressure which can be shown on the integral
indicator or remotely monitored via BRAIN or HART
communications. Other key features include quick
response, remote set-up using communications and
self-diagnostics. FOUNDATION Fieldbus, PROFIBUS
PA and 1 to 5 V DC with HART (Low Power) protocol
types are also available. All EJA-E series models
in their standard configuration, with the exception
of the Fieldbus, PROFIBUS and Low Power types,
are certified as complying with SIL 2 for safety
requirement.

 STANDARD SPECIFICATIONS Specification Conformance


Refer to GS 01C31T02-01EN for Fieldbus EJA-E series ensures specification conformance to at
communication type and GS 01C31T04-01EN for least ±3σ.
PROFIBUS PA communication type for the items
marked with “◊.” Reference Accuracy of Calibrated Span
(includes terminal-based linearity, hysteresis, and
□ SPAN AND RANGE LIMITS repeatability)

Measurement inH2O mbar mmH2O Measurement span F


kPa
Span/Range (/D1) (/D3) (/D4) Reference X ≤ span ±0.055% of Span
Span 0.5 to 5 2.0 to 20 5 to 50
50 to 500 accuracy X > span ±(0.005+0.02 URL/span)% of Span
F* -500 to X 2 kPa (8 inH2O)
Range -5 to 5 -20 to 20 -50 to 50
500 URL
5 kPa (20 inH2O)
Span 0.5 to 10 2.0 to 40 5 to 100 50 to 1000 (upper range limit)
L* -100 to -1000 to
Range -10 to 10 -40 to 40
100 1000
Measurement span M
100 to
Span 1 to 100 4 to 400 10 to 1000 Reference X ≤ span ±0.055% of Span
10000
M accuracy X > span ±(0.005+0.0025 URL/span)% of Span
-100 to -400 to -1000 to -10000 to
Range X 5 kPa (20 inH2O)
100 400 1000 10000
0.05 to 5 URL
Span 5 to 500 20 to 2000 50 to 5000 100 kPa (400 inH2O)
kgf/cm2 (upper range limit)
H
-500 to -2000 to -5000 to -5 to 5
Range
500 2000 5000 kgf/cm2
Measurement span H
0.14 to 14 20 to 2000 1.4 to 140 1.4 to 140
Span Reference X ≤ span ±0.055% of Span
MPa psi bar kgf/cm2
V accuracy X > span ±(0.005+0.01 URL/span)% of Span
-0.5 to 14 -71 to -5 to 140 -5 to 140
Range
MPa 2000 bar kgf/cm2 X 100 kPa (400 inH2O)
*: F capsule is applicable for wetted parts material URL
500 kPa (2000 inH2O)
code S. (upper range limit)
L capsule is applicable for wetted parts material
code other than S.
Measurement span V
□ PERFORMANCE SPECIFICATIONS Reference X ≤ span ±0.055% of Span
Zero-based calibrated span, linear output, wetted accuracy X > span ±(0.005+0.005 URL/span)% of Span
parts material code S and silicone oil, unless X 1.4 MPa (200 psi)
otherwise mentioned. URL
For Fieldbus and PROFIBUS PA communication 14 MPa (2000 psi)
(upper range limit)
types, use calibrated range instead of span in the
following specifications.

Yokogawa Electric Corporation GS 01C31B01-01EN


2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan ©Copyright June 2012
Tel.: 81-422-52-5690 Fax.: 81-422-52-2018 16th Edition June 2017
<<Contents>> <<Index>> 2
[When /HAC is specified] Square Root Output Accuracy
The square root accuracy is a percent of flow span.
Measurement span M
Reference X ≤ span ±0.04% of Span Output Accuracy
accuracy X > span ±(0.002+0.0019 URL/span)% of Span 50% or Greater Same as reference accuracy
X 5 kPa (20 inH2O) Reference accuracy × 50
50% to Dropout point
URL Square root output (%)
100 kPa (400 inH2O)
(upper range limit)
Ambient Temperature Effects per 28°C (50°F)
Change
Measurement span H
Capsule Effect
Reference X ≤ span ±0.04% of Span
F ±(0.08% Span + 0.18% URL)
accuracy X > span ±(0.005+0.0049 URL/span)% of Span M ±(0.07% Span + 0.02% URL)
X 70 kPa (280 inH2O) H ±(0.07% Span + 0.015% URL)
URL V ±(0.07% Span + 0.03% URL)
500 kPa (2000 inH2O)
(upper range limit)
Static Pressure Effects per 6.9 MPa (1000 psi)
Change
Measurement span V Span Effects
Reference X ≤ span ±0.04% of Span F, M, H and V capsules
accuracy X > span ±(0.005+0.0013 URL/span)% of Span ±0.1% of span
X 500 kPa (2000 inH2O) Effect on Zero
URL Capsule Effect
14 MPa (2000 psi)
(upper range limit)
F ±(0.04% span+0.208% URL)
M, H, V ±0.028% URL

 Total Probable Error (M capsule) Overpressure Effects


±0.20% of Span @1:1 to 5:1 Rangedown Overpressure condition: up to maximum working
Total probable error, known as a measure of the total pressure
performance of the transmitters under the condition of M, H and V capsules, except for gold-plated
fixed line presurre. diaphragm.
±0.03% of URL
Stability (All normal operating condition, including
Total Probable Error = ± E12 + E22 + E32
overpressure effects)
E1: Reference Accuracy of Calibrated Span M, H and V capsules
E2: Ambient Temperature Effects per 28°C change ±0.1% of URL per 10 years
E3: Static Span Effects per 6.9 MPa change F capsule
±0.2% of URL per one year
 Total Accuracy (M capsule) Power Supply Effects(Output signal code D and J)
±0.17% of Span @1:1 Rangedown ±0.005 % per Volt (from 21.6 to 32 V DC, 350Ω)
±0.33% of Span @ 5:1 Rangedown Vibration Effects
Total accuracy is a comprehensive measure of Amplifier housing code 1 and 3:
transmitter total performance, covering all major Less than 0.1% of URL when tested per the
factors in actual installation, that cause errors in requirements of IEC60770-1 field or pipeline
measurement. with high vibration level (10-60 Hz, 0.21 mm
As a standard measure, YOKOGAWA uses this to displacement/60-2000 Hz 3 g)
evaluate transmitter performance. Amplifier housing code 2:
Less than ±0.1% of URL when tested per the
requirements of IEC60770-1 field with general
Total Accuracy = ± E12 + E22 + (E3 + E4)2 + E52 application or pipeline with low vibration level (10-60
Hz 0.15mm displacement /60-500 Hz 2g)
E1: Reference Accuracy of Calibrated Span
E2: Ambient Temperature Effects per 28°C change Mounting Position Effects
E3: Static Span Effects per 6.9 MPa change Rotation in diaphragm plane has no effect. Tilting
E4: Static Zero Effects per 6.9 MPa change up to 90 degree will cause zero shift up to 0.4 kPa
E5: Overpressure Effects upto overpressure 16MPa (1.6 inH2O) which can be corrected by the zero
adjustment.
Not only a day-to-day changes in temperature can Response Time (Differential pressure) “◊”
affect the measurement and lead to unnoticed errors; 90 ms for Wetted Parts material code S and L,
fluctuaion of line pressure, incorrect operation of except for Measurement span code F. 150 ms for
three/five valve manifold leading to over-pressure Wetted Parts Material Code H, M, T, A, B, D and W or
events, and other phenomena can have the similar Measurement span code F.
result. Total Accuracy factors in such changes and When amplifier damping is set to zero and including
errors and provides much comprehensive and dead time of 45 ms (nominal)
practical determination of how a transmitter will
perform under actual plant operation.

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01C31B01-01EN June 1, 2017-00
<<Contents>> <<Index>> 3
Static Pressure Signal Range and Accuracy Zero Adjustment Limits
(For monitoring via communication or on Zero can be fully elevated or suppressed, within the
indicator. Includes terminal-based linearity, lower and upper range limits of the capsule.
hysteresis, and repeatability) External Zero Adjustment
Range External zero is continuously adjustable with
Upper Range Value and Lower Range Value of the 0.01% incremental resolution of span. Re-range
static pressure can be set in the range between 0 can be done locally using the digital indicator with
and Maximum Working Pressure(MWP). The upper rangesetting switch.
range value must be greater than the lower range Integral Indicator (LCD display, optional) “◊”
value. Minimum setting span is 0.5 MPa(73 psi). 5-digit numerical display, 6-digit unit display and bar
Measuring either the pressure of high pressure side graph.
or low pressure side is user-selectable. The indicator is configurable to display one or up to
Accuracy four of the following variables periodically.;
Absolute Pressure Measured differential pressure, differential pressure
1 MPa or higher: ±0.5% of span in %, scaled differential pressure, measured static
Less than 1 MPa: ±0.5%×(1 MPa/span) of span pressure. See also “Factory Setting.”
Gauge Pressure Reference Local Parameter Setting
Gauge pressure reference is 1013 hPa (1 atm) (Output signal code D, J and Q)
Note: Gauge pressure variable is based on the above Parameter configuration by the external zero
fixed reference and thus subject to be affected by
the change of atomospheric pressure.
adjustment screw and push button (Integral indicator
code E) offers easy and quick setup for parameters of
□ FUNCTIONAL SPECIFICATIONS Tag number, Unit, LRV, URV, Damping, Output mode
(linear/square root), Display out 1, and Re-range by
Output “◊” applying actual pressure (LRV/URV).
For 4 to 20 mA HART / BRAIN Burst Pressure Limits
(Output signal code D and J) 69 MPa (10,000 psi) for wetted parts material S,
Two wire 4 to 20 mA DC output with digital except for Measurement span F.
communications, linear or square root programmable. 47 MPa (6,800 psi) for wetted parts material other
BRAIN or HART FSK protocol are superimposed on than S or Measurement span F.
the 4 to 20 mA signal.
Output range: 3.6 mA to 21.6 mA Self Diagnostics
Output limits conforming to NAMUR NE43 can be CPU failure, hardware failure, configuration error,
pre-set by option code C2 or C3. and over-range error for differential pressure, static
pressure and capsule temperature.
For 1 to 5 V HART User-configurable process high/low alarm for
(Output signal code Q) differential pressure and static pressure is also
Three or four wire low power 1 to 5 V DC output with available.
HART, linear or square root programmable.
HART protocol are superimposed on the 1 to 5 V DC Signal Characterizer (Output signal code D, J and Q)
signal. User-configurable 10-segment signal characterizer
Output range: 0.9 V to 5.4 V DC for 4 to 20 mA output.
Failure Alarm SIL Certification
For 4 to 20 mA HART / BRAIN EJA-E series transmitters except Fieldbus,
(Output signal code D and J) PROFIBUS PA and 1-5V DC with HART (Low Power)
Analog output status at CPU failure and hardware communication types are certified in compliance with
error; the following standards;
Up-scale: 110%, 21.6 mA DC or more (standard) IEC 61508: 2010; Part1 to Part 7
Down-scale: −5%, 3.2 mA DC or less Functional Safety of Electrical/electronic/
programmable electronic related systems; SIL 2
For 1 to 5 V HART capability for single transmitter use, SIL 3 capability
(Output signal code Q) for dual transmitter use.
Analog output status at CPU failure and hardware
error; □ NORMAL OPERATING CONDITION
Up-scale: 110%, 5.4 V DC or more (standard) (Optional features or approval codes may
Down-scale: −5%, 0.8 V DC or less
affect limits.)
Damping Time Constant (1st order)
Amplifier damping time constant is adjustable from Ambient Temperature Limits
0.00 to 100.00 s by software and added to response −40 to 85°C (−40 to 185°F)
time. −30 to 80°C (−22 to 176°F) with LCD display
Note: For BRAIN protocol type, when amplifier software Process Temperature Limits
damping is set to less than 0.5 s, communication −40 to 120°C (−40 to 248°F)
may occasionally be unavailble during the
operation, especially while output changes Ambient Humidity Limits
dynamically. The default setting of damping 0 to 100% RH
ensures stable communication. Working Pressure Limits (Silicone oil)
Update Period “◊” Maximum Pressure Limits (MWP)
Differential pressure: 45 ms 16 MPa (2300 psi)
Static pressure: 360 ms 25 MPa (3600 psi) for option code /HG

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01C31B01-01EN Feb. 10, 2017-00
<<Contents>> <<Index>> 4
Minimum Pressure Limit For 1 to 5 V HART
See graph below (Output signal code Q)
Power supply :
9 to 28 V DC for general use and flame proof type.
100(14.5) Atmospheric Power Consumption :
pressure 0.96 mA to 3 mA, 27 mW
Working
pressure
Load for 4 to 20 mA HART / BRAIN
kPa abs (Output signal code D and J)
(psi abs) 0 to 1290Ω for operation
250 to 600Ω for digital communication
Applicable range
10(1.4) Output Load for 1 to 5 V HART
(Output signal code Q)
1 MΩ or greater (meter input impedance)
Note that with three-wire connection, the cable length
2.7(0.38) may affect the measurement accuracy of the output
signal.
Communication Requirements “◊”
1(0.14) (Approval codes may affect electrical requirements.)
-40 0 40 80 120
(-40) (32) (104) (176) (248) BRAIN
Process temperature °C (°F) Communication distance
F01E.ai
Up to 2 km (1.25 miles) when using CEV
polyethylene-insulated PVC-sheathed cables.
Figure 1. Working Pressure and Process Temperature Communication distance varies depending on type of
cable used.
Supply & Load Requirements Load capacitance
(Output signal code D and J. Optional features 0.22 µF or less
or approval codes may affect electrical Load inductance
requirements.) 3.3 mH or less
With 24 V DC supply, up to a 550Ω load can be
used. See graph below. Input impedance of communicating device
10 kΩ or more at 2.4 kHz.
EMC Conformity Standards
EN 61326-1 Class A, Table2
EN 61326-2-3
600 EN 61326-2-5 (for fieldbus)
E-10.5 European Pressure Equipment Directive
R=
External 0.0244 Digital 2014/68/EU
load Communication
resistance Sound Engineering Practice (for all capsules)
range
BRAIN and HART With option code /PE3 and /HG (for M, H and V
250
capsules and wetted parts material code S.)

Category III, Module H, Type of Equipment: Pressure


R (Ω) Accessory-Vessel, Type of Fluid: Liquid and Gas,
Group of Fluid: 1 and 2
10.5 16.6 25.2 42 EU RoHS Directive
EN 50581
Power supply voltage E (V DC)
F02E.ai
Safety Requirement Standards
Figure 2. Relationship Between Power Supply EN 61010-1, C22.2 No.61010-1
Voltage and External Load Resistance • Installation category: I
(Output signal code D and J) (Anticipated transient overvoltage 330 V)
• Pollution degree: 2
Supply Voltage “◊” • Indoor/Outdoor use
For 4 to 20 mA HART / BRAIN
(Output signal code D and J)
10.5 to 42 V DC for general use and flameproof type.
10.5 to 32 V DC for lightning protector
(option code /A.)
10.5 to 30 V DC for intrinsically safe, type n, or
nonincendive.
Minimum voltage limited at 16.6 V DC for digital
communications, BRAIN and HART

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01C31B01-01EN June 1, 2017-00
<<Contents>> <<Index>> 5
□ PHYSICAL SPECIFICATIONS < Related Instruments>
FieldMate Versatile Device Management Wizard:
Wetted Parts Materials Refer to GS 01R01A01-01E.
Diaphragm, cover flange, process connector, BRAIN TERMINAL: Refer to GS 01C00A11-00E
capsule gasket, and vent/drain plug Power Distributor: Refer to GS 01B04T01-02E or
Refer to “MODEL AND SUFFIX CODES.” GS 01B04T02-02E
Process connector gasket
PTFE Teflon < Reference >
Fluorinated rubber for option code N2 and N3 • is a registered trademark of Yokogawa
Non-wetted Parts Materials Electric Corporation.
• FieldMate; Trademark of Yokogawa Electric
Bolting Corporation.
B7 carbon steel, 316L SST or 660 SST • Teflon; Trademark of E.I. DuPont de Nemours & Co.
Housing • Hastelloy; Trademark of Haynes International Inc.
• Low copper cast aluminum alloy • HART®: Registered trademark of the FieldComm
• Low copper cast aluminum alloy with corrosion Group.
resistance properties (copper content ≤ 0.03%, • FOUNDATION Fieldbus; Trademark of the
iron content ≤ 0.15%) (optional) FieldComm Group.
• ASTM CF-8M Stainless steel (optional) • PROFIBUS; Registered trademark of Profibus
Coating of housing Nutzerorganisation e.v., Karlsruhe, Germany.
[for aluminum housing] Other company names and product names used in
Urethane curing type polyester resin powder coating this material are registered trademarks or trademarks
Deep sea moss green paint (Munsell 0.6GY3.1/2.0 or of their respective owners.
its equivalent)
[for option code /P or /X2]
Epoxy and polyurethane resin solvent coating
Degrees of protection
IP66/IP67, Type 4X
Cover O-rings
Buna-N, fluoro-rubber (optional)
Name plate and tag
316 SST
Fill fluid
Silicone, fluorinated oil (optional)
Weight
[Installation code 7, 8 and 9]
2.8 kg (6.2 lb) for measurement span code M, H and
V, wetted parts material code S and L without integral
indicator, mounting bracket, and process connector.
3.7 kg (8.2 lb) for measurement span code F without
integral indicator, mounting bracket, and process
connector.
Add 1.5 kg (3.3lb) for Amplifier housing code 2.
Connections
Refer to “MODEL AND SUFFIX CODES.”
Process connection of cover flange: IEC61518

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01C31B01-01EN June 1, 2017-00
<<Contents>> <<Index>> 6
 MODEL AND SUFFIX CODES
Model Suffix Codes Description
EJA110E ............................... Differential pressure transmitter
Output signal -D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 to 20 mA DC with digital communication (BRAIN protocol)
-J . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 to 20 mA DC with digital communication (HART 5/HART 7 protocol)*1
-F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital communication (FOUNDATION Fieldbus protocol, refer to
GS 01C31T02-01EN)
-G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital communication (PROFIBUS PA protocol, refer to
GS 01C31T04-01EN)
-Q . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Low Power, 1 to 5 V DC with digital communication (HART 7 protocol)
Measurement F . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 to 5 kPa (2.0 to 20 inH2O) (For Wetted parts material code S)
span (capsule) L . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 to 10 kPa (2.0 to 40 inH2O)
(For Wetted parts material code M, H, T, A, D, B and W)
M . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 to 100 kPa (4 to 400 inH2O)
H . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 to 500 kPa (20 to 2000 inH2O)
V . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.14 to 14 MPa (20 to 2000 psi)
Wetted parts  . . . . . . . . . . . . . . . . . . . . . . . . . Refer to “Wetted Parts Material” Table.
material *2
Process connections 0 . . . . . . . . . . . . . . . . . . . . . . without process connector (Rc1/4 female on the cover flanges)
See the table in the next1 . . . . . . . . . . . . . . . . . . . . . . with Rc1/4 female process connector
page for the codes for a 2 . . . . . . . . . . . . . . . . . . . . . . with Rc1/2 female process connector
diaphragm seal system. 3 . . . . . . . . . . . . . . . . . . . . . . with 1/4 NPT female process connector
4 . . . . . . . . . . . . . . . . . . . . . . with 1/2 NPT female process connector
► 5 . . . . . . . . . . . . . . . . . . . . . . without process connector (1/4 NPT female on the cover flanges)
Bolts and nuts materia J . . . . . . . . . . . . . . . . . . . B7 carbon steel
G . . . . . . . . . . . . . . . . . . . 316L SST
C . . . . . . . . . . . . . . . . . . . 660 SST
Installation -7 . . . . . . . . . . . . . . . . . Vertical piping, left side high pressure, and process connection downside
-8 . . . . . . . . . . . . . . . . . Horizontal piping and right side high pressure
► -9 . . . . . . . . . . . . . . . . . Horizontal piping and left side high pressure
-B . . . . . . . . . . . . . . . . . Bottom Process Connection, left side high pressure*3
-U . . . . . . . . . . . . . . . . . Universal flange*3
Amplifier housing 1 . . . . . . . . . . . . . . Cast aluminum alloy
3 . . . . . . . . . . . . . . Cast aluminum alloy with corrosion resistance properties*5
2 . . . . . . . . . . . . . . ASTM CF-8M stainless steel*6
Electrical connection 0 . . . . . . . . . . . G1/2 female, one electrical connection without blind plugs
► 2 . . . . . . . . . . . 1/2 NPT female, two electrical connections without blind plugs
4 . . . . . . . . . . . M20 female, two electrical connections without blind plugs
5 . . . . . . . . . . . G1/2 female, two electrical connections and a blind plug*7
7 . . . . . . . . . . . 1/2 NPT female, two electrical connections and a blind plug*7
9 . . . . . . . . . . . M20 female, two electrical connections and a blind plug*7
A . . . . . . . . . . . G1/2 female, two electrical connections and a SUS316 blind plug
C . . . . . . . . . . . 1/2 NPT female, two electrical connections and a SUS316 blind plug
D . . . . . . . . . . . M20 female, two electrical connections and a SUS316 blind plug
Integral indicator D . . . . . . . . Digital indicator*8
E . . . . . . . . Digital indicator with the range setting switch (push button)*9
► N . . . . . . . . None
Mounting bracket ► B . . . . . . 304 SST 2-inch pipe mounting, flat type (for horizontal piping)
D . . . . . . 304 SST or SCS13A 2-inch pipe mounting, L type (for vertical piping)
J . . . . . . 316 SST 2-inch pipe mounting, flat type (for horizontal piping)
K . . . . . . 316 SST or SCS14A 2-inch pipe mounting, L type (for vertical piping)
M . . . . . . 316 SST or SCS14A 2-inch pipe mounting (for bottom process connection type)
N . . . . . . None
Optional Codes / Optional specification

The “►” marks indicate the most typical selection for each specification.
*1: HART 5 or HART 7 is selectable. Specify upon ordering.
*2: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of
inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage
to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm
and the fill fluid can contaminate the user’s process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium
hypochlorite, and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the
wetted parts material.
*3: Only applicable for Wetted parts material code S.
*4: Not applicable for measurement span code F.
*5: Not applicable for electrical connection code 0, 5, 7, 9 and A.
*6: Not applicable for electrical connection code 0, 5, 7 and 9.
*7: Material of a blind plug; aluminum alloy for code 5 and 9, and SUS304 for code 7.
*8: Not applicable for output signal code G.
*9: Not applicable for output signal code F.

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01C31B01-01EN June 1, 2017-00
<<Contents>> <<Index>> 7
Table. Wetted Parts Materials

Wetted parts Cover flange and process


Capsule Capsule gasket Vent/Drain plug
material code connector
Hastelloy C-276 *2 (Diaphragm)
S# ASTM CF-8M *1 Teflon-coated 316L SST 316 SST
F316L SST, 316L SST (Others)
Hastelloy C-276 *2 (Diaphragm)
L# ASTM CF-3M *7 Teflon-coated 316L SST 316L SST
F316L SST, 316L SST (Others)
H# ASTM CF-8M *1 Hastelloy C-276 *2 PTFE Teflon 316 SST
M# ASTM CF-8M *1 Monel PTFE Teflon 316 SST
T ASTM CF-8M *1 Tantalum PTFE Teflon 316 SST
A# Hastelloy C-276 equivalent *3 Hastelloy C-276 *2 PTFE Teflon Hastelloy C-276 *2
D Hastelloy C-276 equivalent *3 Tantalum PTFE Teflon Hastelloy C-276 *2
B# Monel equivalent *4 Monel PTFE Teflon Monel
W# Super Duplex SST equivalent *5 Hastelloy C-276 *2 PTFE Teflon Super Duplex SST *6
*1: Cast version of 316 SST. Equivalent to SCS14A.
*2: Hastelloy C-276 or ASTM N10276.
*3: Indicated material is equivalent to ASTM CW-12MW.
*4: Indicated material is equivalent to ASTM M35-2.
*5: Indicated material is equivalent to ASTM A995 Grade5A.
*6: ASTM S32750 or EN 10272 1.4410.
*7: Cast version of 316L SST. Equivalent to SCS16A.
The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR0175/ISO15156.
Please refer to the latest standards for details. Selected materials also conform to NACE MR0103.

[Process Connections Code for Diaphragm Seal System]


The table below shows the codes dedicated for the combination with a diaphragm seal system. They are only
available when the transmitter is ordered in combination with a diaphragm seal system. Please also refer to GS
01C25W01-01EN.

Process Connections Code High Pressure Side Low Pressure Side


B With C80F, C8FA or C8FD diaphragm seal With C80F, C8FA or C8FD diaphragm seal
C With C80F, C82FA or C82FD diaphragm seal Rc 1/4 female on the cover flange
D With C80F, C82FA or C82FD diaphragm seal 1/4 NPT female on the cover flange
E Rc 1/4 female on the cover flange With C80F, C82FA or C82FD diaphragm seal
F 1/4 NPT female on the cover flange With C80F, C82FA or C82FD diaphragm seal
With C80F, C8FA or C8FD diaphragm seal With C80F, C8FA or C8FD diaphragm seal
G
for high vacuum use for high vacuum use
Q With C20F direct mount seal Rc 1/4 female on the cover flange
R With C20F direct mount seal 1/4 NPT female on the cover flange
C80F, C8FA, C8FD and C20F stand for C80FW or C80FE remote mount flanged diaphragm seal, C81FA or C82FA inner
diaphragm adapter connection seal, C81FD or C82FD inner diaphragm flanged seal, and C20FW or C20FE direct mount seal
respectively.

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01C31B01-01EN June 1, 2017-00
<<Contents>> <<Index>> 8
 OPTIONAL SPECIFICATIONS (For Explosion Protected type) “◊”
For other agency approvals and marine approvals, please refer to GS 01C25A20-01EN.

Item Description Code


Factory Mutual FM Explosionproof Approval *1
(FM) Applicable Standard: FM3600, FM3615, FM3810, ANSI/NEMA 250
Explosionproof for Class I, Division 1, Groups B, C and D, Dust-ignitionproof for Class II/III, Division 1,
FF1
Groups E, F and G, in Hazardous locations, indoors and outdoors (Enclosure: Type 4X)
“FACTORY SEALED, CONDUIT SEAL NOT REQUIRED.”
Temperature class: T6, Amb. Temp.: –40 to 60°C (–40 to 140°F)
FM Intrinsically safe Approval *1 *3
Applicable Standard: FM3600, FM3610, FM3611, FM3810
Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1,
Groups E, F & G and Class III, Division 1, Class I, Zone 0, in Hazardous Locations, AEx ia IIC
Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division. 2,
FS1
Groups F & G, Class I, Zone 2, Group IIC, in Hazardous Locations
Enclosure: Type 4X, Temp. Class: T4, Amb. Temp.: –60 to 60°C (–75 to 140°F)
Intrinsically Safe Apparatus Parameters
[Groups A, B, C, D, E, F and G] Vmax=30 V, Imax=200 mA, Pmax=1 W, Ci=6 nF, Li=0 µH
[Groups C, D, E, F and G] Vmax=30 V, Imax=225 mA, Pmax=1 W, Ci=6 nF, Li=0 µH
Combined FF1 and FS1 *1 *3 FU1
ATEX ATEX Flameproof Approval *1
Applicable Standard: EN 60079-0:2012+A11:2013, EN 60079-1:2007 (“2014” from August 1, 2017),
EN 60079-31:2014
Certificate: KEMA 07ATEX0109 X
II 2G, 2D Ex d IIC T6...T4 Gb (“Ex db IIC T6...T4 Gb” from August 1, 2017), Ex tb IIIC T85°C Db
Degree of protection: IP66/IP67 KF22
Amb. Temp. (Tamb) for gas-proof :
T4; –50 to 75°C (–58 to 167°F), T5; –50 to 80°C (–58 to 176°F), T6; –50 to 75°C (–58 to 167°F)
Process Temp. for gas-proof (Tp):
T4; –50 to 120°C (–58 to 248°F), T5; –50 to 100°C (–58 to 212°F), T6; –50 to 85°C (–58 to 185°F)
Max. surface Temp. for dust-proof: T85°C (Tamb: –30 to 75°C, Tp: –30 to 85°C) *2
ATEX Intrinsically safe Approval *1 *3
Applicable Standard: EN 60079-0:2012+A11:2013, EN 60079-11:2012
Certificate: DEKRA 11ATEX0228 X
II 1G, 2D Ex ia IIC T4 Ga, Ex ia IIIC T85°C T100°C T120°C Db
Degree of protection: IP66/IP67
KS21
Amb. Temp. (Tamb) for EPL Ga: –50 to 60°C (–58 to 140°F)
Maximum Process Temp. (Tp) for EPL Ga:120°C
Electrical data: Ui=30 V, Ii=200 mA, Pi=0.9 W, Ci=27.6 nF, Li=0 µH
Amb. Temp. for EPL Db: –30 to 60°C *2
Max. surface Temp. for EPL Db: T85°C (Tp: 80°C), T100°C (Tp: 100°C), T120°C (Tp: 120°C)
Combined KF22, KS21 and ATEX Intrinsically safe Ex ic *1 *3
[ATEX Intrinsically safe Ex ic]
Applicable Standard: EN 60079-0:2012+A11:2013, EN 60079-11:2012 KU22
II 3G Ex ic IIC T4 Gc, Amb. Temp.: –30 to 60°C (–22 to 140°F) *2
Ui=30 V, Ci=27.6 nF, Li=0 μH

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01C31B01-01EN June 1, 2017-00
<<Contents>> <<Index>> 9
Item Description Code
Canadian CSA Explosionproof Approval *1
Standards Certificate: 2014354
Association Applicable Standard: C22.2 No.0, C22.2 No.0.4, C22.2 No.0.5, C22.2 No.25, C22.2 No.30,
(CSA) C22.2 No.94, C22.2 No.60079-0, C22.2 No.60079-1, C22.2 No.61010-1, C22.2 No.61010-2-030
Explosion-proof for Class I, Groups B, C and D.
Dustignition-proof for Class II/III, Groups E, F and G.
When installed in Division 2, “SEAL NOT REQUIRED” Enclosure: Type 4X,
Temp. Code: T6...T4
CF1
Ex d IIC T6...T4 Enclosure: IP66/IP67
Max.Process Temp.: T4;120°C(248°F), T5;100°C(212°F), T6; 85°C(185°F)
Amb.Temp.: –50 to 75°C(–58 to 167°F) for T4, –50 to 80°C(–58 to 176°F) for T5,
–50 to 75°C(–58 to 167°F) for T6 *2
Process Sealing Certification
Dual Seal Certified by CSA to the requirement of ANSI/ISA 12.27.01
No additional sealing required
Primary seal failure annunciation: at the zero adjustment screw
CSA Intrinsically safe Approval *1 *3
Certificate: 1606623
[For CSA C22.2]
Applicable Standard: C22.2 No.0, C22.2 No.0.4, C22.2 No.25, C22.2 No.94, C22.2 No.157,
C22.2 No.213, C22.2 No.61010-1, C22.2 No.60079-0, C22.2 No.61010-2-030
Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1, Groups E, F & G,
Class III, Division 1, Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division 2,
Groups F & G, Class III, Division 1
Enclosure: Type 4X, Temp. Code: T4 Amb. Temp.: –50 to 60°C(–58 to 140°F) *2
Electrical Parameters: [Intrinsically Safe] Vmax=30V, Imax=200mA, Pmax=0.9W, Ci=10nF, Li=0 µH
[Nonincendive] Vmax=30V, Ci=10nF, Li=0 µH CS1
[For CSA E60079]
Applicable Standard: CAN/CSA E60079-11, CAN/CSA E60079-15, IEC 60529:2001
Ex ia IIC T4, Ex nL IIC T4 Enclosure: IP66/IP67
Amb. Temp.: –50 to 60°C(–58 to 140°F) *2, Max. Process Temp.: 120°C(248°F)
Electrical Parameters: [Ex ia] Ui=30V, Ii=200mA, Pi=0.9W, Ci=10nF, Li=0 µH
[Ex nL] Ui=30V, Ci=10nF, Li=0 µH
Process Sealing Certification
Dual Seal Certified by CSA to the requirement of ANSI/ISA 12.27.01
No additional sealing required
Primary seal failure annunciation: at the zero adjustment screw
Combined CF1 and CS1 *1 *3 CU1
IECEx IECEx Flameproof Approval *1
Applicable Standard: IEC 60079-0:2011, IEC60079-1:2007-4
Certificate: IECEx CSA 07.0008
Flameproof for Zone 1, Ex d IIC T6...T4 Gb Enclosure: IP66/IP67 SF2
Max.Process Temp.: T4;120°C(248°F), T5;100°C(212°F), T6; 85°C(185°F)
Amb.Temp.: –50 to 75°C(–58 to 167°F) for T4, –50 to 80°C(–58 to 176°F) for T5,
–50 to 75°C(–58 to 167°F) for T6
IECEx Intrinsically safe and Flameproof Approval *1*3
Intrinsically safe Ex ia
Certificate: IECEx DEK 11.0081X
Applicable Standard: IEC 60079-0:2011, IEC 60079-11:2011
Ex ia IIC T4 Ga Enclosure: IP66/IP67
Amb. Temp.: –50 to 60 °C(–58 to 140 °F), Max. Process Temp.: 120 °C(248 °F)
Electrical Parameters: Ui=30 V, Ii=200 mA, Pi=0.9 W, Ci=27.6 nF, Li=0 μH
Intrinsically safe Ex ic
Certificate: IECEx DEK 13.0061X
Applicable Standard: IEC 60079-0:2011, IEC 60079-11:2011
SU21
Ex ic IIC T4 Gc IP code: IP66
Amb. Temp.: –30 to 60°C(–22 to 140°F) *2, Max. Process Temp.: 120°C(248°F)
Electrical Parameters: Ui=30V,Ci=27.6 nF, Li=0 μH
Flameproof
Certificate: IECEx CSA 07.0008
Applicable Standard: IEC 60079-0:2011, IEC60079-1:2007-4
Flameproof for Zone 1, Ex d IIC T6...T4 Gb Enclosure: IP66/IP67
Max.Process Temp.: T4;120°C(248°F), T5;100°C(212°F), T6; 85°C(185°F)
Amb.Temp.: –50 to 75°C(–58 to 167°F) for T4, –50 to 80°C(–58 to 176°F) for T5,
–50 to 75°C(–58 to 167°F) for T6
*1: Applicable for Electrical connection code 2, 4, 7, 9, C and D.
*2: Lower limit of ambient temperature is –15°C (5°F) when option code HE is specified.
*3: Not applicable for output signal code Q.

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01C31B01-01EN June 1, 2017-00
<<Contents>> <<Index>> 10
 OPTIONAL SPECIFICATIONS
Item Description Code
High accuracy type *1*20 High accuracy HAC
High pressure-proof structure Maximum working pressure for differential pressure measurement: 25MPa *18 HG
Painting Color change Amplifier cover only*2 P
Amplifier cover and terminal cover, Munsell 7.5 R4/14 PR
Coating change Anti-corrosion coating*3 X2
316 SST exterior parts 316 SST zero-adjustment screw and setscrews*4 HC
Fluoro-rubber O-ring All O-rings of amplifier housing. Lower limit of ambient temperature: –15°C (5°F) HE
Lightning protector Transmitter power supply voltage: 10.5 to 32 V DC (10.5 to 30 V DC for intrinsically safe type.)
Allowable current: Max. 6000 A (1×40 µs), Repeating 1000 A (1×40 µs) 100 times A
Applicable Standards: IEC 61000-4-4, IEC 61000-4-5
Oil-prohibited use*5 Degrease cleansing treatment K1
Degrease cleansing treatment and fluorinated oilfilled capsule.
K2
Operating temperature −20 to 80°C (−4 to 176°F)
Oil-prohibited use with Degrease cleansing and dehydrating treatment K5
dehydrating treatment*5 Degrease cleansing and dehydrating treatment with fluorinated oilfilled capsule.
K6
Operating temperature −20 to 80°C ( −4 to 176°F)
Capsule fill fluid Fluorinated oil filled in capsule
K3
Operating temperature −20 to 80°C (−4 to 176°F)
Calibration units*6 P calibration (psi unit) D1
bar calibration (bar unit) (See Table for Span and Range Limits.) D3
M calibration (kgf/cm2 unit) D4
Long vent*7 Total length: 119 mm (standard: 34 mm); Total length when combining with option code K1,
U1
K2, K5, and K6: 130 mm. Material: 316 SST
Gold-plated capsule gasket *8 Gold-plated 316L SST capsule gasket. Without drain and vent plugs. GS
Gold-plated diaphragm *9 Surface of isolating diaphragms are gold plated, effective Gold plate thickness: 3 μm A1
for hydrogen permeation. Gold plate thickness: 10 μm A2
Output limits and failure Failure alarm down-scale: Output status at CPU failure and hardware error is −5%, 3.2mA DC
C1
operation*10 or less for 4 to 20 mA output type and −5%, 0.8V DC or less for 1 to 5 V output type.
Failure alarm down-scale: Output status at CPU
NAMUR NE43 Compliant C2
failure and hardware error is −5%, 3.2 mA DC or less.
Output signal limits:
3.8 mA to 20.5 mA*21 Failure alarm up-scale: Output status at CPU
C3
failure and hardware error is 110%, 21.6 mA or more.
Body option*11 Right side high pressure, without drain and vent plugs N1
Terminal N1 and Process connection, based on IEC61518 with female thread on both sides of cover
Side N2
flange, with blind kidney flanges on back.
L H N2, and Material certificate for cover flange, diaphragm, capsule body, and blind kidney flange N3
F03E.ai

Wired tag plate 316 SST tag plate wired onto transmitter N4
Data configuration at factory*12 Software damping, Descriptor,
Data configuration for HART communication type CA
Message
Data configuration for BRAIN communication type Software damping CB
European Pressure PED 2014/68/EU
Equipment Directive*19 Category III, Module H, Type of Equipment: Pressure Accessory-Vessel,
PE3
Type of Fluid: Liquid and Gas, Group of Fluid: 1 and 2
Lower limit of ambient and process temperature: −29°C
Material certificate*13 Cover flange *14 M01
Cover flange, Process connector *15 M11
Pressure test/ Test Pressure: 16 MPa(2300 psi) Nitrogen(N2) Gas*17 T12
Leak test certificate*16 Test Pressure: 25 MPa(3600 psi) for option code HG Retention time: one minute T13

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01C31B01-01EN Feb. 10, 2017-00
<<Contents>> <<Index>> 11
*1: Applicable for capsule code M, H and V when combined with wetted parts material code S. Not applicable for /A2.
*2: Not applicable for amplifier housing code 2 and 3.
*3: Not applicable with color change option. Not applicable for amplifier housing code 2.
*4: 316 or 316L SST. The specification is included in amplifier housing code 2.
*5: Applicable for Wetted parts material code S, M, H and T.
*6: The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specified by option codes D1,
D3, and D4.
*7: Applicable for vertical impulse piping type (Installation code 7) and Wetted parts material code S, H, M and T.
*8: Applicable for wetted parts material code S; process connection code 0 and 5; and installation code 8 and 9.
Not applicable for option code U1, N2, N3 and M11. No PTFE is used for wetted parts.
*9: Applicable for wetted parts material code S or L. /A2 is not applicable with FM approval.
*10: Applicable for output signal codes D and J. The hardware error indicates faulty amplifier or capsule.
*11: Applicable for wetted parts material code S, M, H and T; process connection codes 3, 4, and 5; installation code 9; and
mounting bracket code N. Process connection faces on the other side of zero adjustment screw.
*12: Also see ‘Ordering Information’.
*13: Material traceability certification, per EN 10204 3.1B.
*14: Applicable for process connections codes 0 and 5.
*15: Applicable for process connections codes 1, 2, 3, and 4.
*16: The unit on the certificate is always Pa unit regardless of selection of option code D1, D3 or D4.
*17: Pure nitrogen gas is used for oil-prohibited use (option codes K1, K2, K5, and K6).
*18: Applicable for Measurement span code M, H, or V; and wetted parts material code S or L. The URL of static pressure range
is also extended to 25 MPa.
*19: Applicable for measurement span code M, H and V and wetted parts material code S. If compliance with category III is
needed, specify this option code with HG.
*20: Not applicable for output signal code Q.
*21: The 1 to 5 V voltage output corresponding to 4 to 20 mA current output is applied to output signal code Q which is non-
compliant to NAMUR NE43.

 OPTIONAL SPECIFICATIONS (FOR DIAPHRAGM SEAL SYSTEM)


The table below shows the codes dedicated for the combination with a diaphragm seal system. They are only
available when the transmitter is ordered in combination with a diaphragm seal system. Please also refer to GS
01C25W01-01EN

Item Descriptions Code


Oil-prohibited use Degrease cleansing treatment K11
Degrease cleansing treatment and fluorinated oil-filled capsule. K12
Operating temperature −20 to 80°C (−4 to 176°F)
Oil-prohibited use with Degrease cleansing and dehydrating treatment K15
dehydrating treatment
Degrease cleansing and dehydrating treatment with fluorinated oil-filled capsule.Operating K16
temperature −20 to 80°C ( −4 to 176°F)
Capsule fill fluid Fluorinated oil filled in capsule K13
Operating temperature −20 to 80°C (−4 to 176°F)
Material certificate Material Certificate: [Low pressure side] Cover flange M02
Material Certificate: [High pressure side] Cover flange M03
Material Certificate: Bolts and nuts for cover flanges M51
Material Certificate: [Low pressure side] Cover flange, bolts and nuts for cover flanges. M62
Material Certificate: [High pressure side] Cover flange, bolts and nuts for cover flanges. M63

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01C31B01-01EN June 1, 2017-00
<<Contents>> <<Index>> 12
 DIMENSIONS
Unit: mm (approx.inch)

● Vertical Impulse Piping Type (INSTALLATION CODE ‘7’)


Wetted Parts Material code: S and L (except for Measurement Span code F)
Electrical connection
for code 5, 9, A, and D.
Process connector downside

54 (0.24)
(Installation code 7)

6
242(9.53) 110(4.33)

(2.13)
175(6.89)
12 39
97 129(5.08) 2-inch pipe
(3.82) (0.47) (1.54) (O.D. 60.5 mm)
Mounting bracket External indicator
(L-type,optional) Conduit connection
(2.05)

(optional) Vent/Drain
52

Integral indicator plugs


(optional)
97(3.82)
223(8.78)

ø78(3.07)

138(5.43)*2
95(3.74)

ø70(2.76)
(1.61)
67(2.64)
41

Process
Conduit connector
connection (optional)
41.3 Process connection 54
Zero adjustment High Low
(1.63) pressure (2.13) pressure
Ground terminal side*1 side*1 F04E.ai

● Horizontal Impulse Piping Type (INSTALLATION CODE ‘9’)


(For CODE ‘8’, refer to the notes below.)
Wetted Parts Material code: S and L (except for Measurement Span code F)
Conduit
External indicator 89(3.50) 67 connection 110(4.33)
Conduit connection (2.64) Zero
12 39
(optional) 95(3.74) Integral indicator adjustment
(0.47) (1.54)
(optional)
54
ø78(3.07)

(2.76)

(2.13)
ø70

6
175(6.89)
145(5.71)

129(5.08)

(0.24)
Vent plug, Ground
Drain plug*4 terminal Vent plug*4

Electrical connection Vent plug*4


for code 5, 9, A, and D.
Drain plug*4 Drain plug*4
124(4.88)

41
54(2.13)
(1.61) Process Low
High
115(4.53) connection pressure pressure
side*1 side*1
(1.63)
41.3

Process connector
(1.85)
47

Mounting bracket (optional) 2-inch pipe


(Flat-type,optional) (O.D. 60.5 mm)
130(5.12)*3 F05E.ai

*1: When installation code 8 is selected, high and low pressure side on above figure are reversed.
(i.e. High pressure side is on the right side.)
*2: When option code K1, K2, K5 or K6 is selected, add 15 mm (0.59 inch) to the value in the figure.
*3: When option code K1, K2, K5 or K6 is selected, add 30 mm (1.18 inch) to the value in the figure.
*4: Not available when option code GS is selected.
*5: When electrical connection code 7 or C is selected, a blind plug is protruded upto 8 mm from the conduit connection.

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01C31B01-01EN June 1, 2017-00
<<Contents>> <<Index>> 13
Unit: mm (approx.inch)

● Vertical Impulse Piping Type (INSTALLATION CODE ‘7’)


Wetted Parts Material code: H, M, T, A, B, D and W or Measurement Span code F
Electrical connection
for code 5, 9, A, and D.

(0.24)
6
256(10.10)
194(7.64) 110(4.33)

(2.13)
54
97 143(5.63) 9*4 39
2-inch pipe
(3.82) (0.35) (1.54)
(O.D. 60.5 mm)
Mounting bracket
(L-type,optional) External indicator Vent/Drain plugs
Conduit connection
(2.05)

(optional)
52

Integral indicator
(optional)
102(4.02)
234(9.21)

ø78(3.07)

148(5.83)*2
(3.74)

(2.76)
ø70
95
(1.81)
72(2.83)
46

Process
Conduit connector
connection (optional) 54
41.3 Process connection
Zero adjustment High (2.13) Low
(1.63) Ground terminal pressure pressure
side*1 side*1 F06E.ai

● Horizontal Impulse Piping Type (INSTALLATION CODE ‘9’)


(For CODE ‘8’, refer to the notes below.)
Wetted Parts Material code: H, M, T, A, B, D and W or Measurement Span code F
External indicator Conduit connection
Conduit connection 94(3.70) 72(2.83) 110(4.33)
(optional) Zero
95(3.75) adjustment 9*4 39
Integral indicator
54 (optional) (0.35) (1.54)
ø78(3.07)

(2.13)
6
(2.76)
ø70

(0.24)
159(6.26)

143(5.63)
194(7.64)

Ground terminal
Electrical connection
for code 5, 9, A, and D.
Vent plug
Vent plug
Drain plug
124(4.88)

46 Process connection Drain plug


(1.81) 54
High Low
125(4.92) Process connector pressure (2.13) pressure
(optional) side*1 side*1
(1.63)
41.3

2-inch pipe
(1.85)

(O.D. 60.5 mm)


47

Mounting bracket
(Flat-type,optional)

133*3
(5.24) F07E.ai

*1: When Installation code 8 is selected, high and low pressure side on above figure are reversed.
(i.e. High pressure side is on the right side.)
*2: When Option code K1, K2, K5, or K6 is selected, add 15 mm (0.59 inch) to the value in the figure.
*3: When Option code K1, K2, K5, or K6 is selected, add 30 mm (1.18 inch) to the value in the figure.
*4: 15 mm (0.59 inch) for right side high pressure.
*5: When electrical connection code 7 or C is selected, a blind plug is protruded upto 8 mm from the conduit connection.

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01C31B01-01EN June 1, 2017-00
<<Contents>> <<Index>> 14
Unit: mm (approx.inch)

● Universal Flange (INSTALLATION CODE ‘U’)


Measurement Span code M, H and V
58 67 110(4.33)
(2.28) (2.64) Zero
External indicator
Conduit connection Conduit connection adjustment 12 39
95(3.74)
(optional) Integral indicator (0.47) (1.54)
54 (optional)

ø78(3.07)
(2.13)
6

(2.76)
ø70
145(5.71)

(0.24)

129(5.08)
175(6.89)
Ground terminal

Electrical connection
for code 5, 9, A, and D.
Vent plug
Drain plug
41 54 Drain plug
High Low
Vent plug (1.61) (2.13)
(1.63)

pressure pressure
41.3

115(4.53) side 130*1 side


Process connection
Drain plug (5.12)
Process connector
(optional)
F08E.ai

● Universal Flange (INSTALLATION CODE ‘U’)


Measurement Span code F

External indicator 63 72 Zero 110(4.33)


Conduit connection adjustment
Conduit connection (2.48) (2.83)
9 39
(optional) 95(3.74) Integral indicator
(0.35) (1.54)
54 (optional)
ø78(3.07)

(2.13)
6

(2.76)
ø70
(0.24)
159(6.26)

143(5.63)
194(7.64)

Ground terminal

Electrical connection
for code 5, 9, A, and D.
Vent plug
Drain plug
46 Drain plug
54
(1.63)

Vent plug (1.81) High (2.13) Low


41.3

Process connection pressure pressure


125(4.92) side 133(5.24)*1 side
Drain plug Process connector (optional) F09E.ai

*1: When Option code K1, K2, K5, or K6 is selected, add 30 mm (1.18 inch) to the value.
*2: When electrical connection code 7 or C is selected, a blind plug is protruded upto 8 mm from the conduit connection.

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01C31B01-01EN June 1, 2017-00
<<Contents>> <<Index>> 15
Unit: mm (approx.inch)

● Bottom Process Connection Type (INSTALLATION CODE ‘B’)


Measurement span code M, H and V
54
(2.13) 95(3.74)
6 188(7.40)
73 Integral indicator
(0.24) (2.87) Zero 110(4.33)
(optional)
adjustment
12 39
Conduit connection (0.47) (1.54)
Electrical connection

ø78(3.07)
for code 5, 9, A, and D.

(2.76)
ø70

109(4.29)
159(6.26)
Extenal indicator
Conduit connection
(optional)
Ground terminal

Mounting bracket*1 41.3


(2.36)
60

(optional) (1.63)
Vent plug
54
2-inch pipe Process connector
High (2.13) Low
(O.D. 60.5 mm) (optional) pressure pressure
side 130(5.12)*2 side
Process connection
129(5.08)
F10E.ai

● Bottom Process Connection Type (INSTALLATION CODE ‘B’)


Measurement span code F
192(7.56)
95(3.74) Integral indicator
(optional) 110(4.33)
Extenal indicator Zero
adjustment 9 39
Conduit connection 95(3.74) Conduit connection (0.35) (1.54) Vent plug
(optional)
ø78(3.07)

(2.76)
ø70
159(6.26)

143(5.63)
238(9.37)

Ground terminal

Vent plug
79(3.11)

41.3
(1.63)
2-inch pipe
(O.D. 60.5 mm) Process connector 54
High (2.13) Low
(optional) pressure pressure
side 133(5.24)*2 side
Mounting bracket
54 (optional) 129(5.08)
(2.13)
6
(0.24)

Electrical connection
for code 5, 9, A, and D. F11E.ai

*1: A transmitter with SST housing is not applicable for mounting to horizontal 2-inch pipe.
*2: When Option code K1, K2, K5, or K6 is selected, add 30 mm (1.18 inch) to the value.
*3: When electrical connection code 7 or C is selected, a blind plug is protruded upto 8 mm from the conduit connection.

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01C31B01-01EN June 1, 2017-00
<<Contents>> <<Index>> 16

● Terminal Configuration ● Terminal Wiring for 4 to 20 mA output,


FOUNDATION Fieldbus and PROFIBUS PA
communication types
+ 1
Power supply and output terminals
SUPPLY – 2

CHECK + 3
– 2
External indicator (ammeter) terminals*1*2

Ground terminal

*1: When using an external indicator or check meter, the internal


resistance must be 10 Ω or less.
*2: Not available for FOUNDATION Fieldbus and PROFIBUS PA
Terminal 1 Terminal 3 communication types.
Terminal 2
● Terminal Wiring for 1 to 5 V output
+ 1
Power supply terminals
SUPPLY – 2

VOUT + 3 1 to 5 V DC with HART communication


– 2 terminals
Ground terminal

Three or four wire connection. For four wire connection, both supply
and signal lines use SUPPLY - terminal.
F12E.ai

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01C31B01-01EN Nov. 7, 2016-00
<<Contents>> <<Index>> 17

< Ordering Information > “◊” < Factory Setting > “◊”
Specify the following when ordering
Tag number As specified in order
1. Model, suffix codes, and option codes
2. Calibration range and units Software
‘2.00 s’ or as specified in order
1) Calibration range can be specified with range damping *1
value specifications up to 5 digits (excluding Output mode ‘Linear’ unless otherwise specified in order
any decimal point) for low or high range limits Calibration range
As specified in order
within the range of -32000 to 32000. When lower range value
reverse range is designated, specify Lower Calibration range
Range Value(LRV) as greater than Upper Range upper range As specified in order
Value(URV). When square root output mode is value
specified, LRV must be “0 (zero) ”. Selected from mmH2O, mmH2O(68°F),
2) Specify only one unit from the table, ‘Factory mmAq*2, mmWG*2, mmHg, Pa, hPa*2,
setting.’ Calibration range kPa, MPa, mbar, bar, gf/cm2,
3. Select linear or square root for output mode and unit kgf/cm2, inH2O, inH2O(68°F), inHg, ftH2O,
ftH2O(68°F) or psi. (Only one unit can be
display mode. specified.)
Note: If not specified, the instrument is shipped set for
linear mode. Designated differential pressure value
4. Display scale and units (for transmitters equipped specified in order. (% or user scaled
Display setting
value.) Display mode ‘Linear’ or ‘Square
with the integral indicator only)
root’ is also as specified in order.
Specify either 0 to 100 % or ‘Range and Unit’ for
engineering units scale: Static pressure ‘0 to 16 MPa (25 MPa*3)’ absolute value.
display range Measuring high pressure side.
Scale range can be specified with range limit
specifications up to 5 digits (excluding any decimal *1: To specify these items at factory, option code CA
point) for low or high range limits within the range or CB is required.
of -32000 to 32000. Unit display consists of 6-digit, *2: Not available for HART protocol type.
therefore, if the specified scaling unit excluding ‘/’ is *3: Applicable for option code HG.
longer than 6-characters , the first 6 characters will
be displayed on the unit display. < Material Cross Reference >
5. HART PROTOCOL
When output signal code is “J”, specify the HART ASTM JIS
protocol revision “5” or “7”. 316 SUS316
6. TAG NO (if required) F316 SUSF316
Specified characters (up to 16 characters for 316L SUS316L
BRAIN, 22 characters for HART, and 16 characters
F316L SUSF316L
for /N4 tag) are engraved on the stainless steel tag
plate fixed on the housing. 304 SUS304
7. SOFTWARE TAG (for HART only. if required) F304 SUSF304
Specified characters (up to 32 characters) are set 660 SUH660
as “Tag” (the first 8 characters) and “Long tag”*1 B7 SNB7
(32 characters) in the amplifier memory. Use CF-8M SCS14A
alphanumeric capital letters.
When the “SOFTWARE TAG” is not specified,
specified “TAG NO” is set as “Tag” (the first 8
characters) and “Long tag”*1 (22 characters) in the
amplifier memory.
*1: applicable only when HART 7 is selected.
8. Other factory configurations (if required)
Specifying option code CA or CB will allow further
configuration at factory. Following are configurable
items and setting range.
[/CA : For HART communication type]
1) Descriptor (up to 16 characters)
2) Message (up to 30 characters)
3) Software damping in second (0.00 to 100.00)
[/CB : For BRAIN communication type]
1) Software damping in second (0.00 to 100.00)

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01C31B01-01EN June 1, 2017-00
Subject to change without notice.
ATTACHMENT-3
CATALOGUE OF TEMPERATURE
TRANSMITTER
<<Contents>> <<Index>>

General YTA710
Specifications Temperature Transmitter

GS 01C50G01-01EN

The YTA710 is the highly accurate temperature


transmitter that accepts Thermocouple, RTD, ohms or
DC millivolts inputs and converts it to a 4 to 20 mA DC
or Fieldbus signal for transmission.
The YTA710 supports HART, BRAIN and FOUNDATION
fieldbus communication protocols.
HART and BRAIN types are certified as complying
with SIL 2 for safety requirement.

 FEATURES  STANDARD SPECIFICATIONS


High reliability
Dual-compartment housing realizes high resistance ■ PERFORMANCE SPECIFICATIONS
capability to harsh environments. Accuracy
Variety of sensor inputs HART and BRAIN communication type:
The type of sensor input is user-selectable from A/D accuracy/span + D/A accuracy
thermocouples (T/C), RTDs, ohms, or DC millivolts. (See Table 1 on page 4.)
Digital communication Fieldbus communication type:
HART protocol revision is 7 and FOUNDATION fieldbus. A/D accuracy (See Table 1 on page 4.)
The instrument configuration can be changed by the Cold Junction Compensation Accuracy
user with using the Fieldmate or Handheld terminal. ± 0.5°C (± 0.9 °F) for T/C only
Local Parameter Setting Include influence of the ambient temperature.
Parameter configuration by the push button offers Ambient Temperature Effect (per 10°C change)
easy and quick setup for parameters. See Table 2 on page 5.
Self-diagnostics function Stability
Continuous self-diagnostics capability ensures RTD: ±0.1% of reading or ±0.1°C per 2 years,
longterm performance and lower cost of ownership. whichever is greater at 23±2°C.
Dual universal inputs T/C: ±0.1% of reading or ±0.1°C per year, whichever
Dual input can accept two thermocouple, RTD, is greater at 23±2°C.
ohm or DC millivolt inputs. Differential or average 5 Year Stability
temperature measurement is selectable. The sensor RTD: ±0.2% of reading or ±0.2°C,
backup function for automatically switches-over from whichever is greater at 23±2°C.
the primary to the backup upon sensor failure. T/C: ±0.4% of reading or ±0.4°C,
whichever is greater at 23±2°C.
Vibration Effect
The YTA710 are tested to the following specifications
with no effect on performance per IEC 60770-1
10 to 60 Hz 0.21 mm peak displacement
60 to 2000 Hz 3g
Power Supply Effect (HART and BRAIN type)
±0.005% of calibrated span per volt

Yokogawa Electric Corporation GS 01C50G01-01EN


2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan ©Copyright May 2016 (YK)
Tel.: 81-422-52-5690 Fax.: 81-422-52-2018 17th Edition Mar. 2, 2018 (YK)
<<Contents>> <<Index>> 2
■ FUNCTIONAL SPECIFICATIONS Fieldbus functions (Fieldbus type)
Functional specifications for Fieldbus communication
Input Signals conform to the standard specifications (H1) of
Input number: single and dual input FOUNDATION Fieldbus.
Input type is selectable: Thermocouples, 2-, 3-, and
4-wire RTDs, ohms and DC millivolts. Function Block (Fieldbus type)
See Table 1. on page 4. Resource block
Input Signal Source Resistance (for T/C, mV) The resource block contains physical transmitter
1 kΩ or lower information.
Input Lead Wire Resistance (for RTD, ohm) Transducer block
10 Ω per wire or lower The transducer block contains the actual
measurement data and information about sensor
Span & Range Limits type and configuration and diagnostics.
See Table 1. on page 4.
LCD display block
Output signals The LCD display block is used to configure the local
Two wire 4 to 20 mA DC type display, if an LCD display is being used.
Output range: 3.68 to 20.8 mA Analog input (AI)
HART or BRAIN protocol is superimposed on the 4 Four independent AI blocks can be selected.
to 20 mA signal. Any single value among followings
can be selected as the analog output signal. Digital input (DI)
Sensor 1, Terminal Temperature. Four DI function blocks can be used as a limit
Dual input type, same as above plus; switch for those temperature.
Sensor 2, Average, and Differential Temperature. Other function block
Also, up to three of the above values can As other Function blocks, Arithmetic (AR), Signal
be displayed on LCD display or read via Characterizer (SC), Input Selector (IS), and two PID
communication. function blocks are available.
Fieldbus type Function block Execution time (ms)
Output signal based on FOUNDATION fieldbus AI 30
communication protocol.
DI 30
Isolation SC 30
Input/Output/GND isolated to 500V DC
IS 30
Except lightning protector option.
AR 30
Manual Test Output Function
PID 45
The output value can be set manually.
Sensor Burnout (HART and BRAIN type) Link master function
High (21.6 mA DC) or Low (3.6 mA DC), user This function enables backup of network manager
selectable. and local control only by field devices.
Output in Transmitter Failure (HART and BRAIN type) Alarm function
Down-scale: –5%, 3.2 mA DC or less , sensor Fieldbus models securely support various alarm
burnout –2.5%, 3.6 mA (Optional code C1) functions, such as High/Low alarm, notice of
Down-scale: –5%, 3.2 mA DC or less (Optional code block error, etc. based on FOUNDATION fieldbus
C2) specifications.
Up-scale: 110%, 21.6 mA DC or more (Standard or Software download function
Optional code C3) This function permits to update YTA software via a
Update Time (HART and BRAIN type) FOUNDATION fieldbus.
Approximately 0.5 seconds for a single sensor (0.8 Based on Foundation fieldbus specifications
second for dual sensors) at damping time 0 (FF883)
Turn-on Time (HART and BRAIN type) Download class: Class 1
Approximately 6 seconds for a single sensor (7 EMC Conformity Standards
seconds for dual sensors) EN61326-1 Class A, Table2
Damping Time Constant EN61326-2-3
Selectable from 0 to 100 seconds EN61326-2-5 (for fieldbus type)
Self-Diagnostics SIL Certification (HART type)
Self-diagnostic function based on the NAMUR Hart type certified in compliance with IEC 61508:
NE107 standard detects failures in the hardware, 2010.
configuration and communications. Functional Safety of Electrical/electronic/
Programmable electronic related systems;
Sensor-Diagnostics SIL 2 capability for single transmitter use
Sensor failure: Detect the disconnection of sensor. SIL 3 capability for dual transmitter use
Sensor short: Detect the short circuit of the sensor.
Sensor Corrosion: Measure the loop resistance.
Sensor line information: Measure the line resistance.
Sensor drift: Detect the difference between sensor1
and sensor2.
Temperature Cycle Diagnostics: Count the number of
temperature fluctuations.

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C50G01-01EN Mar. 2, 2018-00
<<Contents>> <<Index>> 3
Safety Requirement Standards Communication Requirements (BRAIN type)
EN61010-1, C22.2 No.61010-1 Communication Distance
• Installation category: I Up to 2 km (1.25 miles) when using CEV
(Anticipated transient overvoltage 330 V) polyethylene-insulated PVC-sheathed cables.
• Pollution degree: 2 Communication distance varies depending on type
• Indoor/Outdoor use of cable used.
EN61010-2-030, C22.2 No.61010-2-030 Load Capacitance
• Measurement category: O (Other) 0.22 μF or less
(Measurement Input voltage: 150mVdc max) Load Inductance
EU RoHS Directive 3.3 mH or less
Applicable standard: EN 50581 Input Impedance of communicating device
10 kΩ or more at 2.4 kHz.
■ NORMAL OPERATING CONDITION Load Requirements (HART and BRAIN type)
(Optional features or approval codes may affect limits.) 0 to 1290Ω for operation
250 to 600Ω for digital communication
Ambient Temperature Limits
–40 to 85°C (–40 to 185°F) ■ PHYSICAL SPECIFICATIONS
–30 to 80°C (–22 to 176°F) (with indicator model)
Ambient Humidity Limits Enclosure
0 to 100% RH at 40°C (104°F) Material & coating
Supply Voltage Requirements • Low copper cast aluminum alloy
[for aluminum housing]
HART and BRAIN type Urethane-cured polyester powder coating
10.5 to 42 V DC for general use and flameproof type Mint-green paint (Munsell 5.6BG 3.3/2.9 or its
10.5 to 32 V DC for lightning protector (option code /A) equivalent)
10.5 to 30 V DC for intrinsically safe and [for option code /P or /X2]
non-incendive type Epoxy and polyurethane resin solvent coating
Minimum voltage limited at 16.6 V DC for digital • ASTM CF-8M Stainless steel
communications HART
With 24 V DC supply, up to a 550Ω load can be Degrees of protection
used. See graph below. IP66/IP67, TYPE 4X
Name plate and tag
316 SST
Mounting
600 Optional mounting brackets can be used either for
two-inch pipe or flat panel mounting.
E-10.5
R= Terminal screws
External 0.0244 Digital
load Communication M4 screws
resistance range Integral Indicator (with indicator model)
HART and BRAIN
5-digit numerical display, 6-digit unit display and bar
250 graph.
R (Ω)
Local Parameter Setting (with indicator model)
Parameter configuration by the push button offers
easy and quick setup for parameters.
Accessible parameters are different with each output
10.5 16.6 25.2 42 cord.
Power supply voltage E (V) Weight
F01E.ai Aluminum housing:
Figure 1. Relationship Between Power Supply 1.3 kg (2.9 lb) without integral indicator and mounting
Voltage and External Load Resistance Integral indicator: 0.2 kg (0.4 lb)
Bracket for horizontal pipe: 0.3 kg
Fieldbus type Bracket for vertical pipe: 1.0 kg
9 to 32V DC for general use, flameproof type, and Stainless housing:
non-incendive type 3.1 kg (6.8 lb) without integral indicator and mounting
9 to 30 V DC for intrinsically safe type Integral indicator: 0.3 kg (0.7 lb)
9 to 17.5 V DC for FISCO field device Connections
Communication Requirements Refer to “MODEL AND SUFFIX CODE.”
Supply Voltage: 9 to 32 V DC
Current Draw:
Steady state: 15 mA (max)
Software download state: 24 mA (max)

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C50G01-01EN Mar. 2, 2018-00
<<Contents>> <<Index>> 4
Table 1. Sensor type, measurement range, and accuracy

Measurement Range Minimum A/D Accuracy D/A


Sensor Type Standard
°C °F Span °C °F Accuracy
100 to 300 212 to 572 ±3.0 ±5.4
B
300 to 1820 572 to 3308 ±0.75 ±1.35
-200 to -50 -328 to -58 ±0.35 ±0.63
E
-50 to 1000 -58 to 1832 ±0.16 ±0.29
-200 to -50 -328 to -58 ±0.25 ±0.45
J
-50 to 1200 -58 to 2192 ±0.20 ±0.36
-200 to -50 -328 to -58 ±0.5 ±0.9
K
-50 to 1372 -58 to 2501 ±0.25 ±0.45
-200 to -50 -328 to -58 ±0.4 ±0.72
N
-50 to 1300 -58 to 2372 ±0.35 ±0.63
IEC60584 -50 to 0 -58 to 32 ±1.0 ±1.8
R 0 to 600 32 to 1112 ±0.6 ±1.08
600 to 1768 1112 to 3214 ±0.4 ±0.72
-50 to 0 -58 to 32 ±1.0 ±1.8
S 0 to 600 32 to 1112 25°C ±0.5 ±0.9
T/C
600 to 1768 1112 to 3214 (45°F) ±0.4 ±0.72
-200 to -50 -328 to -58 ±0.25 ±0.45
T
-50 to 400 -58 to 752 ±0.14 ±0.25
0 to 400 32 to 752 ±0.7 ±1.26
400 to 1400 752 to 2552 ±0.5 ±0.9
C ±0.02%
1400 to 2000 2552 to 3632 ±0.7 ±1.26
of span
2000 to 2300 3632 to 4172 ±0.9 ±1.62
0 to 400 32 to 752 ±0.8 ±1.44
ASTM 400 to 1400 752 to 2552 ±0.5 ±0.9
W3
E988 1400 to 2000 2552 to 3632 ±0.6 ±1.08
2000 to 2300 3632 to 4172 ±0.9 ±1.62
-200 to -50 -328 to -58 ±0.3 ±0.54
L
-50 to 900 -58 to 1652 ±0.2 ±0.36
DIN43710
-200 to -50 -328 to -58 ±0.35 ±0.63
U
-50 to 600 -58 to 1112 ±0.25 ±0.45
Pt100 -200 to 850 -328 to 1562 ±0.1 ±0.18
Pt200 -200 to 850 -328 to 1562 ±0.22 ±0.40
IEC60751
Pt500 -200 to 850 -328 to 1562 ±0.14 ±0.25
Pt1000 -200 to 300 -328 to 572 10°C ±0.1 ±0.18
RTD
JPt100 — -200 to 500 -328 to 932 (18°F) ±0.1 ±0.18
SAMA
Cu10 -70 to 150 -94 to 302 ±1.0 ±1.8
RC21-4
Ni120 — -70 to 320 -94 to 608 ±0.08 ±0.15
mV — -10 to 120 [mV] 3 mV ±0.012 [mV]
ohm — 0 to 2000 [Ω] 20 Ω ±0.35 [Ω]
Note 1: Total Accuracy = (A/D Accuracy / Span + D/A Accuracy) or (± 0.1% of calibrated span), whichever is greater.
Accuracy of Fieldbus type: A/D Accuracy.
For T/C input, add Cold Junction Compensation Error (± 0.5°C) to the total accuracy.
Example: when selecting Pt100 with measurement range of 0 to 200 °C
0.1°C / 200°C×100% of span +0.02% of span = 0.07% of span
Since the value is smaller than ±0.1% of span, the total accuracy is ±0.1%.
Note 2: T/C C type is same as W5 (ASTM E988).

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C50G01-01EN Jan. 15, 2018-00
<<Contents>> <<Index>> 5
Table 2. Temperature coefficient

Sensor Type Temperature Coefficient


Thermocouples E, J, K, N, T, L, U 0.08°C + 0.02% of abs.reading
Thermocouples R, S, W3, C 0.25°C + 0.02% of abs.reading
Thermocouple B 100°C ≤ Reading < 300°C 1°C + 0.02% of abs.reading
300°C ≤ Reading 0.5°C + 0.02% of abs.reading
RTD 0.08°C + 0.02% of abs.reading
mV 0.002 mV + 0.02% of abs.reading
ohm 0.1 Ω + 0.02% of reading
Note1: The “abs.reading” for thermocouples and RTD means the absolute value of the reading in °C.
Example of “abs.reading”
When the temperature value is 250 Kelvin, “abs.reading” is 23.15.
|250−273.15|= 23.15
Note2: Ambient Temperature Effect per 10 °C change is ±0.1% or ±(temperature coefficient/span), whichever is greater.
Example of Ambient Temperature Effect
Conditions:
1) Input Sensor: Pt100
2) Calibration Range: −100 to 100°C
3) Reading value: −50°C
Ambient Temperature Effect per 10°C
Temperature Coefficient/Span=(0.08°C+0.02/100×|−50°C|)/{100°C−(−100°C)}= 0.00045 → 0.045%
Therefore, Ambient Temperature Effect is ±0.1%/10°C
Note3: See also Table 3 for R1 option.

 MODEL AND SUFFIX CODES


Model Suffix Codes Description
YTA710 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Temperature Transmitter
Output signal -D. . . . . . . . . . . . . . . . . . . . . . . . . . . 4 to 20 mA DC with digital communication BRAIN protocol
-J. . . . . . . . . . . . . . . . . . . . . . . . . . . 4 to 20 mA DC with digital communication HART protocol
-F. . . . . . . . . . . . . . . . . . . . . . . . . . . Digital communication (FOUNDATION Fieldbus protocol)
— A. . . . . . . . . . . . . . . . . . . . . . . Always A
Sensor input 1 . . . . . . . . . . . . . . . . . . . . Single
2 . . . . . . . . . . . . . . . . . . . . Double
Housing code A. . . . . . . . . . . . . . . . Aluminum
C. . . . . . . . . . . . . . . . Stainless
Electrical connection 0 . . . . . . . . . . . . . G1/2 female
2 . . . . . . . . . . . . . 1/2 NPT female
4 . . . . . . . . . . . . . M20 female
Integral indicator D. . . . . . . . . . Digital indicator with Local Operating Switch
N. . . . . . . . . . None
Mounting bracket B. . . . . . SUS304 stainless steel 2-inch horizontal pipe mounting bracket *1
D. . . . . . SUS304 stainless steel 2-inch vertical pipe mounting bracket
J . . . . . . SUS316 stainless steel 2-inch horizontal pipe mounting bracket *1
K. . . . . . SUS316 stainless steel 2-inch vertical pipe mounting bracket
N. . . . . . None
Option codes / Optional specification
*1: For flat-panel mounting, please prepare bolts and nuts.

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C50G01-01EN Mar. 2, 2018-00
<<Contents>> <<Index>> 6
 OPTIONAL SPECIFICATION
Item Description Code
Lightning protector *4 Allowable current: Max. 6000A(8×20µs), repeating 1000A(8×20µs), 100 times A
Painting*1*6 Color and coating change Color: Munsell code N1.5 Black
P1
Amplifier cover only*3 Coating: High anti-corrosion coating
Color: Munsell code 7.5BG4/1.5, Jade green
P2
Coating: High anti-corrosion coating
Color: Metallic silver
P7
Coating: High anti-corrosion coating
Color and coating change Color: Munsell code 7.5 R4/14, Red
PR
Amplifier and terminal Covers*3 Coating: High anti-corrosion coating
Coating change High anti-corrosion coating X2
Output signal low-side in Output signal Low-side: –5%, 3.2 mA DC or less.
C1
transmitter failure*2 Sensor burnout is also set to 'Low': –2.5%, 3.6 mA DC.
NAMUR NE43 compliant*2 Output signal limits: Failure alarm down-scale: output status at CPU failure and
3.8 mA to 20.5 mA hardware error is –5%, 3.2 mA or less. C2
Sensor burnout is also set to Low: –2.5%, 3.6 mA DC.
Failure alarm up-scale: output status at CPU failure and hardware
error is 110%, 21.6 mA or more. C3
In this case Sensor burnout is High: 110%, 21.6 mA DC.
Data configuration*9 Description into “Descriptor” parameter of HART protocol (max. 16 characters) CA
Wired tag plate SUS316 stainless steel tag plate wired onto transmitter N4
Sensor matching RTD sensor matching function CM1
Attached flameproof Electrical connection G1/2 female
2pc. V52
packing adapter*5*7 Applicable cable: O.D.8.0 to 12 mm
EAC approval and EAC approval and Russian pattern approval marking
Russian pattern approval VR
marking*8*10
EAC approval marking EAC approval marking without Russian pattern approval marking
without Russian pattern VE
approval marking*8*10
High ambient-temp Refer to Table 3 Temperature coefficient
R1
characteristic type*8
Note: The indication of the nameplate shows an initial shipment state.
*1: Not applicable for Stainless housing.
*2: Not applicable for Fieldbus type.
*3: Except for Amplifier and terminal cover, color and coating are general specification.
*4: Lightning protector (surge absorber) can be remove from, or added to the equipment.
*5: Combination with other Explosion protected other than TIIS flameproof is not possible.
*6: The combination of X2 and P is not possible.
*7: Applicable for Electrical Connection code 4. (The thread of connection between YTA and CABLE GLAND is M20,
and the thread of connection between CABLE GLAND and CABLE is G1/2.)
*8: Not applicable for BRAIN type.
*9: Applicable for only HART type.
*10: Combination with other Explosion protected other than EAC Explosion-proof type is not applicable.

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C50G01-01EN Mar. 2, 2018-00
<<Contents>> <<Index>> 7
Table 3. Temperature coefficient (R1 option)

Input Range
Sensor Type A/D Coefficient D/A Coefficient
°C
100 to 300 ±(0.586°C - 0.1433% of reading)
B 300 to 1000 ±(0.187°C - 0.0103% of reading)
1000 to 1820 ±(0.038°C + 0.0046% of reading)
-200 to 0 ±(0.007°C + 0.0158% of abs.reading)
E
0 to 1000 ±(0.007°C + 0.0065% of reading)
-200 to 0 ±(0.009°C + 0.0172% of abs.reading)
J
0 to 1200 ±(0.009°C + 0.0065% of reading)
-200 to 0 ±(0.011°C + 0.0218% of abs.reading)
K
0 to 1372 ±(0.011°C + 0.0078% of reading)
-200 to 0 ±(0.017°C + 0.0265% of abs.reading)
N
0 to 1300 ±(0.017°C + 0.0063% of reading)
-50 to 0 ±(0.088°C + 0.1273% of abs.reading)
R 0 to 200 ±(0.088°C - 0.0142% of reading)
T/C 200 to 1768 ±(0.048°C + 0.0058% of reading)
-50 to 0 ±(0.088°C + 0.0517% of abs.reading)
S 0 to 200 ±(0.088°C - 0.0106% of reading)
200 to 1768 ±(0.054°C + 0.0063% of reading)
-200 to 0 ±(0.011°C + 0.0195% of abs.reading)
T ±{0.0088% of span + 0.007%
0 to 400 ±(0.011°C + 0.0044% of reading)
of(reading − LRV)}
0 to 1400 ±(0.034°C + 0.0069% of reading)
C
1400 to 2315 ±( -0.157°C + 0.0205% of reading)
0 to 1400 ±(0.044°C + 0.0053% of reading)
W3
1400 to 2315 ±( -0.214°C + 0.0237% of reading)
-200 to 0 ±(0.009°C + 0.0117% of abs.reading)
L
0 to 900 ±(0.009°C + 0.0052% of reading)
-200 to 0 ±(0.011°C + 0.0148% of abs.reading)
U
0 to 400 ±(0.011°C + 0.0046% of reading)
Pt100 -200 to 850 ±(0.015°C + 0.005% of reading)
Pt200 -200 to 850 ±(0.023°C + 0.012% of reading)
Pt500 -200 to 850 ±(0.015°C + 0.005% of reading)
RTD Pt1000 -200 to 300 ±(0.015°C + 0.005% of reading)
JPt100 -200 to 500 ±(0.015°C + 0.005% of reading)
Cu10 -70 to 150 ±(0.320°C + 0.120% of reading)
Ni120 -70 to 320 ±(0.010°C + 0.005% of reading)
mV -10 to 120 [mV] ±(0.441uV + 0.0065% of abs.reading)
ohm 0 to 2000 [Ω] ±(0.040Ω + 0.0088% of reading)
Note: Temperature Effect = A/D coeffieicnt + D/A coefficient (The data in the table is the coeffcient per 10°C change.)
Example 1; Pt100Ω, 0 to 200°C calibration range, 50°C reading
(0.015°C + 50°C × 0.005%) + [200°C × 0.0088% + (50 - 0) × 0.007%]
= (0.015°C + 0.0025°C) + (0.0176°C + 0.0035°C )
= ± 0.0386°C [ per 10°C change ]
Example 2; T T/C, -100 to 100°C calibration range, -50°C reading
(0.011°C + | -50°C | × 0.0195%) + {200°C × 0.0088% + [-50 - (-100)] × 0.007%}
= (0.011°C + 0.00975°C) + (0.0176°C + 0.0035°C )
= ± 0.04185°C [ per 10°C change ].

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C50G01-01EN Mar. 2, 2018-00
<<Contents>> <<Index>> 8
 OPTIONAL SPECIFICATION (For Explosion Protected type)
Item Description Code
ATEX [4-20mA & Fieldbus: Flameproof and dust ignition proof approval]
Applicable Standard: EN 60079-0:2012+A11:2013, EN 60079-1:2014, EN 60079-31:2014
Certificate: KEMA 07ATEX0130
II 2 G Ex db IIC T6/T5 Gb, II 2 D Ex tb IIIC T70°C/T90°C Db
KF2
Ambient Temperature for Gas Atmospheres: –40 to 75°C for T6, –40 to 80°C for T5
Ambient Temperature for Dust Atmospheres: –30 to 65°C for T70°C, –30 to 80°C for T90°C
Enclosure: IP66/IP67
Electrical Connection: 1/2 NPT female and M20 female*1
4-20mA:
[Intrinsically safe ia approval]
Applicable Standard: EN 60079-0:2012+A11:2013, EN 60079-11:2012
Certificate No. FM16ATEX0019X
II 1 G Ex ia IIC T5…T4 Ga
Ambient Temperature: –40 to 70°C for T4, –40 to 50°C for T5
Enclosure: IP66/IP67
Electrical parameters:
Supply/Output circuit: Terminals: +, –
Ui=30V, Ii=200mA, Pi=1.0W, Ci=22nF, Li=0mH
Sensor circuit: Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10μF, Lo=3.9mH
Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A)
[Intrinsically safe ic]
KU2
Applicable Standard: EN 60079-0:2012+A11:2013, EN 60079-11:2012
Certificate: Not Applicable as per Annex VIII to ATEX 2014/34/EU
II 3 G Ex ic IIC T5...T4 Gc
Ambient Temperature: –30 to 70°C for T4, –30 to 50°C for T5
Enclosure: IP66/IP67
Overvoltage category: I
Electrical parameters:
Supply/Output circuit: Terminals: +, –
Ui=32V, Ci=2.2nF, Li=0mH
Sensor circuit: Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10μF, Lo=3.9mH
Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A)
[Flameproof and Dust Ignition Proof Approval]
Same as KF2
Fieldbus:
[Intrinsically safe ia approval]
Applicable Standard: EN 60079-0:2012+A11:2013, EN 60079-11:2012
Certificate No. FM16ATEX0019X
II 1 G Ex ia IIC T4 Ga
Ambient Temperature: –55 to 60°C
Enclosure: IP66/IP67
Electrical parameters:
Supply/Output circuit: Terminals: +, –
FISCO field device or
Ui=30V, Ii=300mA, Pi=1.2W, Ci=2.2nF, Li=0mH
Sensor circuit: Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10μF, Lo=3.9mH
Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A)
[Intrinsically safe ic] KU25
Applicable Standard: EN 60079-0:2012+A11:2013, EN 60079-11:2012
Certificate: Not Applicable as per Annex VIII to ATEX 2014/34/EU
II 3 G Ex ic IIC T4 Gc
Ambient Temperature: –30 to 70°C
Enclosure: IP66/IP67
Electrical parameters:
Supply/Output circuit: Terminals: +, –
FISCO field device or
Ui=32V, Ci=2.2nF, Li=0mH
Sensor circuit: Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10μF, Lo=3.9mH
Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A)
[Flameproof and Dust Ignition Proof Approval]
Same as KF2

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C50G01-01EN Mar. 2, 2018-00
<<Contents>> <<Index>> 9
Item Description Code
IECEx [4-20mA & Fieldbus: Flameproof and dust ignition proof approval]
Applicable standard: IEC 60079-0:2011, IEC 60079-1:2014, IEC 60079-31:2013
Certificate: IECEx KEM 07.0044
Ex db IIC T6/T5 Gb, Ex tb IIIC T70°C/T90°C Db
Ambient Temperature for Gas Atmospheres: –40 to 75°C (–40 to 167°F) for T6,
SF2
–40 to 80°C (–40 to 176°F) for T5
Ambient Temperature for Dust Atmospheres: –30 to 65°C (–22 to 149°F) for T70°C,
–30 to 80°C (–22 to 176°F) for T90°C
Enclosure: IP66/IP67
Electrical Connection: 1/2 NPT female and M20 female*1
4-20mA:
[Intrinsically safe ia, ic pproval]
Applicable Standard: IEC 60079-0:2011, IEC 60079-11:2011
Certificate No. IECEx FMG 16.0014X
Ex ia IIC T5…T4 Ga
Ex ic IIC T5...T4 Gc
Ambient Temperature: –40 to 70°C for T4, –40 to 50°C for T5(Ex ia)
Ambient Temperature: –30 to 70°C for T4, –30 to 50°C for T5(Ex ic)
Enclosure: IP66/IP67
Over voltage category: I
Electrical parameters (Ex ia)
Supply/Output circuit: Terminal: +, – SU2
Ui=30V, Ii=200mA, Pi=1.0W, Ci=22nF, Li=0mH
Sensor circuit: Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10μF, Lo=3.9mH
Electrical parameters (Ex ic)
Supply/Output circuit: Terminal: +, –
Ui=30V, Ci=22nF, Li=0mH
Sensor circuit: Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10μF, Lo=3.9mH
Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A)
[Flameproof and Dust Ignition Proof Approval]
Same as SF2
Fieldbus:
[Intrinsically safe ia approval]
Applicable Standard: IEC 60079-0: 2011, IEC 60079-11: 2011
Certificate No. IECEx FMG 16.0014X
Ex ia IIC T4 Ga
Ex ic IIC T4 Gc
Ambient Temperature: –55 to 60°C (Ex ia)
Ambient Temperature: –30 to 70°C (Ex ic)
Enclosure: IP66/IP67
Overvoltage category: I
Electrical parameters (Ex ia)
Supply/Output circuit: Terminals: +, –
FISCO field device or SU25
Ui=30V, Ii=300mA, Pi=1.2W, Ci=2.2nF, Li=0mH
Sensor circuit: Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10μF, Lo=3.9mH
Electrical parameters (Ex ic)
Supply/Output circuit: Terminals: +, –
FISCO field device or
Ui=32V, Ci=2.2nF, Li=0mH
Sensor circuit:Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10μF, Lo=3.9mH
Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A)
[Flameproof and Dust Ignition Proof Approval]
Same as SF2

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C50G01-01EN Mar. 2, 2018-00
<<Contents>> <<Index>> 10
Item Description Code
FM (US) [4-20mA & Fieldbus: Explosionproof approval]
Applicable standard: FM Class 3600: 2011, FM Class 3615: 2006, FM Class 3810: 2005,
NEMA250: 2014
Class I, Division 1, Groups A, B, C and D.;
Class II/III, Division 1, Groups E, F and G.
FF1
"FACTORY SEALD, CONDUIT SEAL NOT REQUIRED."
Enclosure Ratings: TYPE 4X
Temperature Class: T6
Ambient Temperature: –40 to 60°C (–40 to 140°F)
Electrical Connection: 1/2NPT female*2
4-20mA:
[Intrinsically safe approval/non-incendive approval]
Applicable standard: FM Class 3600:2011, FM Class 3610:2015, FM Class 3611:2004,
FM Class 3810:2005, ANSI/ISA-60079-0:2013, ANSI/ISA-60079-11:2014, NEMA 250:2003,
ANSI/IEC 60529:2004
Intrinsically safe for
Class I, II, III Division 1, Groups A, B, C, D, E, F, G, T5…T4
Class I Zone 0 AEx ia IIC T5…T4
Non-incendive for
Class I, II, Division 2, Groups A, B, C, D, F, G, T5…T4
Class III, Division 1 T5…T4
Class I Zone 2 Group IIC T5…T4
Ambient Temperature: –40 to 70°C for T4, –40 to 50°C for T5
Enclosure Type 4X, IP66/IP67
FU1
Electrical parameters:
Intrinsically safe for
Supply/Output circuit: Terminals: +, –
Ui=30V, Ii=200mA, Pi=1.0W, Ci=22nF, Li=0mH
Sensor circuit: Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10μF, Lo=3.9mH
Non-incendive for
Supply/Output circuit: Terminals: +, –
Ui=30V, Ci=22nF, Li=0mH
Sensor circuit:Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10μF, Lo=3.9mH
Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A)
[Explosionproof approval]
Same as FF1
Fieldbus:
[Intrinsically safe approval/non-incendive approval]
Applicable standard: FM Class 3600:2011, FM Class 3610:2015, FM Class 3611:2004,
FM Class 3810:2005, ANSI/ISA-60079-0:2013, ANSI/ISA-60079-11:2014, NEMA 250:2003,
ANSI/IEC 60529:2004
Intrinsically safe for
Class I, II, III Division 1, Groups A, B, C, D, E, F, G T4
Class I Zone 0 AEx ia IIC T4
Non-incendive for
Class I, II, Division 2, Groups A, B, C, D, F, G T4
Class III, Division 1 T4 Class I Zone 2 Group IIC T4
Ambient Temperature: –55 to 60°C
Enclosure Type 4X, IP66/IP67
Electrical parameters:
FU15
Intrinsically safe for
Supply/Output circuit: Terminals: +, –
FISCO field device or
Ui=30V, Ii=300mA, Pi=1.2W, Ci=2.2nF, Li=0mH
Sensor circuit: Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10μF, Lo=3.9mH
Non-incendive for
Supply/Output circuit: Terminals: +, –
Ui=32V, Ci=2.2nF, Li=0mH
Sensor circuit: Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10μF, Lo=3.9mH
Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A)
[Explosionproof approval]
Same as FF1

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C50G01-01EN Mar. 2, 2018-00
<<Contents>> <<Index>> 11
Item Description Code
CSA*3*6 [4-20mA & Fieldbus: Explosionproof approval]
Applicable standard: C22.2 No. 0-10, C22.2 No. 0.4-04, C22.2 No. 25-M1966, C22.2 No. 30-M1986,
FM (Canada)*4*6 C22.2 No. 94-M1991, C22.2 No. 142-M1987, C22.2 No. 157-92, C22.2 No. 213-M1987,
C22.2 No.61010-1-12, C22.2 No. 61010-2-030-12
Class I, Groups B, C and D,
Class II, Groups E, F and G,
Class III. CF1
For Class I, Division2 Groups ABCD Locations “FACTORY SEALED, CONDUIT SEAL NOT
REQUIRED”
Enclosure TYPE 4X
Temperature Class: T6
Ambient Temperature: –40 to 60°C
Electrical Connection: 1/2 NPT female*2
4-20mA:
[Intrinsically safe approval/non-incendive approval]
Applicable standard: CAN/CSA-C22.2 No. 94.2-07, C22.2 No.213:1987,
CAN /CSA-C22.2 No. 60079-0:11, CAN/CSA-C22.2 No. 60079-11:14,
CAN/CSA-C22.2 No. 60529:05, CAN/CSA-C22.2 No. 61010-1-12,
CAN/CSA-C22.2 No. 61010-2-030-12
Intrinsically safe for
Class I, II, III, Division 1, Groups A, B, C, D, E, F, G, T5…T4
Ex ia IIC T5…T4 Ga
Non-incendive for
Class I, II, Division 2, Groups A, B, C, D, F, G T5…T4
Class III Division 1 T5…T4
Ambient Temperature: –40 to 70°C for T4, –40 to 50°C for T5
Enclosure Type: 4X, IP66/IP67
CU1
Electrical parameters:
Intrinsically safe for
Supply/Output circuit: Terminals: +, –
Ui=30V, Ii=200mA, Pi=1.0W, Ci=22nF, Li=0mH
Sensor circuit: Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10μF, Lo=3.9mH
Non-incendive for
Supply/Output circuit: Terminals: +, –
Ui=30V, Ci=22nF, Li=0mH
Sensor circuit: Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10μF, Lo=3.9mH
Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A)
[Explosionproof approval]
Same as CF1
Fieldbus:
[Intrinsically safe approval/non-incendive approval]
Applicable standard: CAN/CSA-C22.2 No. 94.2-07, C22.2 No.213:1987,
CAN /CSA-C22.2 No. 60079-0:11, CAN/CSA-C22.2 No. 60079-11:14,
CAN/CSA-C22.2 No. 60529:05, CAN/CSA-C22.2 No. 61010-1-12,
CAN/CSA-C22.2 No. 61010-2-030-12
Intrinsically safe for
Class I, II, III, Division 1, Groups A, B, C, D, E, F, G T4
Ex ia IIC T4 Ga
Non-incendive for
Class I, II, Division 2, Groups A, B, C, D, F, G T4
Class III Division 1 T4
Ambient Temperature: –55 to 60°C
Enclosure Type: 4X, IP66/IP67
Electrical parameters: CU15
Intrinsically safe for
Supply/Output circuit: Terminals: +, –
FISCO field device or
Ui=30V, Ii=300mA, Pi=1.2W, Ci=2.2nF, Li=0mH
Sensor circuit: Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10μF, Lo=3.9mH
Non-incendive for
Supply/Output circuit: Terminals: +, –
Ui=30V, Ii=300mA, Pi=1.2W, Ci=2.2nF, Li=0mH
Sensor circuit: Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10μF, Lo=3.9mH
Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A)
[Explosionproof approval]
Same as CF1

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C50G01-01EN Mar. 2, 2018-00
<<Contents>> <<Index>> 12
Item Description Code
NEPSI 4-20mA and Fieldbus:
[Flameproof and Dust Ignition Proof Approval]
Applicable Standard: GB3836.1-2010, GB3836.2-2010, GB12476.1-2013, GB12476.5-2013
Certificate No. GYJ16.1396X
Ex d IIC T6/T5 Gb, Ex tD A21 IP66/IP67 T70°C/T90°C NF2
Ambient Temperature for Gas Atmospheres: –40 to 75°C for T6, –40 to 80°C for T5
Ambient Temperature for Dust Atmospheres: –30 to 65°C for T70°C, –30 to 80°C for T90°C
Enclosure: IP66/IP67
Electrical Connection: 1/2 NPT female and M20 female*1
4-20mA:
[Intrinsically safe approval ]
Applicable Standard: GB 3836.1-2010, GB 3836.4-2010 GB 3836.20-2010
Certificate No. GYJ16.1423X
Ex ia IIC T4/T5 Ga
Ambient Temperature: –40 to 70°C for T4, –40 to 50°C for T5
Enclosure: IP66/IP67 in accordance with only IEC 60529 NS2
Entity Parameters:
Supply/Output circuit: Ui=30V, Ii=200mA, Pi=1.0W, Ci=22nF, Li=0mH
Sensor circuit: Uo=6V, Io=90mA, Po=135mW, Co=10μF, Lo=3.9mH
Dielectric strength: 500 V a.c.r.m.s.,1 min
[+, -, C, 1, 2, 3, 4, 5] to Earth terminal
[+, -, C] to [1, 2, 3, 4, 5]
Fieldbus:
[Intrinsically safe approval]
Applicable Standard: GB 3836.1-2010, GB 3836.4-2010, GB3836.20-2010
Certificate No. GYJ16.1423X
Ex ia IIC T4 Ga
Ambient Temperature: –55 to 60°C for T4
Enclosure: IP66/IP67 in accordance with only IEC 60529
NS25
FISCO field device
Entity Parameters:
Supply/Output circuit: Ui=30V, Ii=300mA, Pi=1.2W, Ci=2.2nF, Li=0mH
Sensor circuit: Uo=6V, Io=90mA, Po=135mW, Co=10μF, Lo=3.9mH
Dielectric strength: 500 V a.c.r.m.s.,1 min
[+, -, 1, 2, 3, 4, 5] to Earth terminal
[+, -] to [1, 2, 3, 4, 5]

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C50G01-01EN Mar. 2, 2018-00
<<Contents>> <<Index>> 13
Item Description Code
INMETRO*6 [4-20mA & Fieldbus: Flameproof and dust ignition proof approval]
Applicable Standard: ABNT NBR IEC 60079-0:2013 Versão Corrigida 2: 2016,
ABNT NBR IEC60079-1:2016, ABNT NBR IEC 60079-31:2014
Certificate: DEKRA 16.0009
Ex db IIC T6/T5 Gb, Ex tb IIIC T70°C/ 90°C Db UF1
Ambient Temperature for Gas: –40 to +75°C for T6, –40 to +80°C for T5
Ambient Temperature for Dust: –30 to +65°C for T70°C, –30 to +80°C for T90°C
Enclosure: IP66/IP67
Electrical Connection: 1/2 NPT female and M20 female*1
4-20mA:
[Intrinsically safe approval ]
Applicable Standard: ABNT NBR IEC 60079-0:2013 Versão Corrigida 2:2016,
ABNT NBR IEC 60079-11:2013
Certificate: ABNT 17.0001X
Ex ia IIC T5...T4 Ga
Ambient Temperature: –40 to 70 °C for T4, –40 to 50 °C for T5 US1
Enclosure: IP66/IP67
Supply/Output circuit:
Ui=30V, Ii=200mA, Pi=1.0W, Ci=22nF, Li=0mH
Sensor circuit:
Uo=6V, Io=90mA, Po=135mW, Co=10μF, Lo=3.9mH
Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A)
Fieldbus:
[Intrinsically safe approval "ia" ]
Applicable Standard: ABNT NBR IEC 60079-0:2013 Versão Corrigida 2:2016,
ABNT NBR IEC 60079-11:2013
Certificate: ABNT 17.0001X
Ex ia IIC T4 Ga
Ambient Temperature: –55 to 60 °C
Enclosure: IP66/IP67
Supply/Output circuit:
FISCO field device and
Ui=30V, Ii=300mA, Pi=1.2W, Ci=2.2nF, Li=0mH
Sensor circuit:
Uo=6V, Io=90mA, Po=135mW, Co=10μF, Lo=3.9mH
Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A)
US15
[Intrinsically safe approval "ic" ]
Applicable Standard: ABNT NBR IEC 60079-0:2013 Versão Corrigida 2:2016,
ABNT NBR IEC 60079-11:2013
Certificate: ABNT 17.0001X
Ex ic IIC T4 Gc
Ambient Temperature: –30 to 70 °C
Enclosure: IP66/IP67
Overvoltage category: I
Supply/Output circuit:
FISCO field device and
Ui=32V, Ci=2.2nF, Li=0mH
Sensor circuit:
Uo=6V, Io=90mA, Po=135mW, Co=10μF, Lo=3.9mH
Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A)

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C50G01-01EN Mar. 2, 2018-00
<<Contents>> <<Index>> 14
Item Description Code
KOSHA [4-20mA & Fieldbus: Flameproof and dust ignition proof approval]
Applicable Standard: Notice of Ministry of Labor No. 2016-54, harmorized with IEC
60079-0:2011, IEC 60079-1:2014, IEC 60079-31:2013
Certificate: 17-AV4BO-0457 (Flameproof)
17-AV4BO-0458 (Dust Ignition Proof)
PF2
Ex d IIC T6/ T5, Ex tD A21 IP66/IP67 T70°C/ T90°C
Ambient Temperature for Gas Atmospheres: –40 to 75°C for T6, –40 to 80°C for T5
Ambient Temperature for Dust Atmospheres: –30 to 65°C for T70°C, –30 to 80°C for T90°C
Enclosure: IP66/IP67
Electrical Connection: 1/2 NPT female and M20 female*1
4-20mA:
[Intrinsically safe approval]
Applicable Standard: Notice of Ministry of Labor No. 2016-54, harmorized with
IEC 60079-0: 2011, IEC 60079-11: 2011
Certificate: 17-AV4BO-0459X
Ex ia IIC T5…T4
Ambient Temperature: –40 to 70 °C for T4, –40 to 50 °C for T5
Enclosure: IP66/IP67
PS2
Supply/Output circuit:
Terminals: +, –
Ui=30V, Ii=200mA, Pi=1.0W, Ci=22nF, Li=0mH
Sensor circuit:
Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10μF, Lo=3.9mH
Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A)
Electrical Connection: 1/2 NPT female and M20 female*1
Fieldbus:
[Intrinsically safe approval]
Applicable Standard: Notice of Ministry of Labor No. 2016-54, harmorized
with IEC 60079-0: 2011, IEC 60079-11: 2011
Certificate: 17-AV4BO-0459X
Ex ia IIC T4
Ambient Temperature: –55 to 60°C
Enclosure: IP66/IP67
Supply/Output circuit: PS25
Terminals: +, –
FISCO field device and
Ui=30V, Ii=300mA, Pi=1.2W, Ci=2.2nF, Li=0mH
Sensor circuit:
Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10μF, Lo=3.9mH
Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A)
Electrical Connection: 1/2 NPT female and M20 female*1

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C50G01-01EN Mar. 2, 2018-00
<<Contents>> <<Index>> 15
Item Description Code
EAC*6 [4-20mA & Fieldbus: Flameproof and dust ignition proof approval]
Applicable Standard: ГОСТ 31610.0-2014
ГОСТ IEC 60079-1-2013
ГОСТ IEC 60079-31-2013
Certificate: TC RU C-JP.ПБ98.B.00040
GF1*5
1Ex db IIC T6…T5 Gb, Ex tb IIIC T70 °C…T90 °C Db
Ambient Temperature for Gas Atmospheres: –40 to 75°C for T6, –40 to 80°C for T5
Ambient Temperature for Dust Atmospheres: –30 to 65°C for T70°C, –30 to 80°C for T90°C
Enclosure: IP66/IP67
Electrical Connection: 1/2 NPT female and M20 female*1
4-20mA:
[Intrinsically safe approval]
Applicable Standard: ГОСТ 31610.0-2014
ГОСТ 31610.11-2014
Certificate: TC RU C-JP.ПБ98.B.00040
0Ex ia IIC T4…T5 Ga X
Ambient Temperature: –40 to 70 °C for T4, –40 to 50 °C for T5
Enclosure: IP66/IP67
GS1*5
Supply/Output circuit:
Terminals: +, –
Ui=30V, Ii=200mA, Pi=1.0W, Ci=22nF, Li=0mH
Sensor circuit:
Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10μF, Lo=3.9mH
Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A)
Electrical Connection: 1/2 NPT female and M20 female*1
Fieldbus:
[Intrinsically safe approval]
Applicable Standard: ГОСТ 31610.0-2014
ГОСТ 31610.11-2014
Certificate: TC RU C-JP.ПБ98.B.00040
0Ex ia IIC T4 Ga X
Ambient Temperature: –55 to 60°C
Enclosure: IP66/IP67
Supply/Output circuit: GS15*5
Terminals: +, –
FISCO field device and
Ui=30V, Ii=300mA, Pi=1.2W, Ci=2.2nF, Li=0mH
Sensor circuit:
Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10μF, Lo=3.9mH
Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A)
Electrical Connection: 1/2 NPT female and M20 female*1
*1: Applicable for Electrical Connection Code 2 and 4.
*2: Applicable for Electrical Connection Code 2.
*3: For Explosionproof approval.
*4: For Intrinsically safe approval/non-incendive approval.
*5: GF1, /GS1 and /GS15 shall be combined with either /VE or /VR.
*6: Not applicable for BRAIN type.

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C50G01-01EN Mar. 2, 2018-00
<<Contents>> <<Index>> 16
 DIMENSIONS
Unit: mm (Approx. inch)
 2-inch horizontal pipe mounting
111(4.37) 65.4(2.57) 66.1(2.60)
Electrical Connection
Electrical Connection 47.1 18.5
(Input signal) Terminal Cover
(Output signal) (1.85) (0.73)
With Indicator
(Optional)

ø93(3.66)
102(4.02)
164(6.46)

Shrouding Bolt Ground Terminal

(1.57)
(For Explosionproof type)

40
Tag Plate

Horizontal Pipe

(0.98)
25
Mounting Bracket
(Optional)

56(2.21) 2-inch pipe


ø60.5(ø2.38)

 2-inch vertical pipe mounting


111(4.37) 65.4(2.57) 66.1(2.60)
Electrical Connection
Electrical Connection (Input signal) 47.1 Terminal Cover
18.5
(Output signal) (1.85) (0.73)
With Indicator
(Optional)

ø93(3.66)
Shrouding Bolt
(For Explosionproof type)
209.5(8.25)
191.5(7.54)

Ground Terminal
Tag Plate
Vertical Pipe
Mounting Bracket
(1.81)

(Optional)
46

2-inch pipe
64(2.52)
ø60.5(ø2.38) 101(3.98)
70(2.76)
98(3.86)
F02E.ai

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C50G01-01EN Mar. 2, 2018-00
<<Contents>> <<Index>> 17
 Terminals

Terminal Configuration

Power supply and output terminal


Communication
Terminals External indicator (ammeter) termial *1
Connection hook
Ground terminal
CHECK METER *1 : When using an external indicator or a check meter,
Connection hook *1 the internal resistance must be 10Ω or less.
The hook is not available for Fieldbus
M10×1.5 12-deep female communication type.
for mounting bracket
F03E.ai

 Input Wiring

Single input Dual input


(A) (A1)
1 1 1 (+) 1 (B1)
(+)
2 2 2 2 (B1)
(B)
3 (–)
3 3 (–) 3
(B2)
4 4 4 4 (B2)
5 5 5 (+)
5 (A2)

Thermocouple and RTD and resistance Thermocouple and RTD and resistance
DC voltage (2-wire) DC voltage (3-wire)
(A) (A) (A1)
1 1 1 (+) 1
(B) (A) (B1)
2 2 2 (–) 2
(B) (B)
3 3 3 (B2) 3
(B) (B2)
4 4 4 (B2) 4
(A2)
5 5 5 (A2) 5
RTD and resistance RTD and resistance Thermocouple + RTD and resistance
(3-wire) (4-wire) RTD and resistance (2-wire)
(3-wire)
(A1)
1 (B1)
2 (B1)
3 (–)

4
5 (+)

RTD and resistance


(3-wire)
+ Thermocouple
F04E.ai

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C50G01-01EN Mar. 2, 2018-00
<<Contents>> <<Index>> 18
< Ordering Information > 6. Output scale unit
Specify the following when ordering Model, suffix Specify only one unit from the table, ‘Settings when
codes, and optional codes. shipped.’ For sensor input code-2, specify the unit
If not specified, the instrument is shipped with the for two inputs.
settings shown in Table A and B. Specify the following 7. Tag Number
when necessary. Specify Tag number (up to 16 Characters) to be
engraved on the tag plate.
8. Software Tag (PD_TAG)
4-20mA type (HART and BRAIN type) Specify software tag (up to 32 Characters) to be
1. Sensor type. written on the amplifier memory.
For RTD and resistance input, specify the number 9. Node Address
of wire as well. (Example: Pt100 3-wire system) 10. Operation Functional Class
For sensor input code-2, specify the type for two Select ‘BASIC’ or ‘LINK MASTER’.
inputs. In this case, PV (Sensor1 value) and SV 11. Sensor back up
(Sensor2 value) are alternately displayed on the Select ‘DISABLE’ or ‘ENABLE’.
integral indicator with sensor back up DISABLE.
2. Calibration range and unit
1) Calibration range can be specified within the < Factory Setting >
measurement range shown in Table 1. Also, set
the upper limit is larger than the lower limit. Table A. 4-20mA type (HART and BRAIN type)
2) Specify one range from °C, K, °F or °R for
temperature input. It is not necessary to specify Input sensor type *1 “Pt100” or as specified in order
the unit of mV and ohm inputs, for these units Wire connection “3-wire system” or as specified in
automatically will be mV or Ω. (For RTD) *1 order
3. Tag Number (if required) Calibration range “0 to 100” or as specified in order
Specify Tag number (up to 16 Characters) to be Calibration unit “°C” or as specified in order
engraved on the tag plate. The specified letters (TC and RTD)
are written on Tag (16 Characters) in the amplifier Sensor burnout *2 High (110%, 21.6 mA DC)
memory. Output in Transmitter High (110%, 21.6 mA DC or more)
4. Software tag (HART type) failure *2
Specified characters (up to 32 characters) are Sensor backup ‘DISABLE’ or as specified
set as “Tag” (the first 8 characters) and “Long
Tag No. “Blank” or as specified in order
tag (32 characters) in the amplifier memory.
Use alphanumeric capital letters. When the *1: For sensor input code-2, sensor 2 is set in
“SOFTWARE TAG” is not specified, “TAG NO” is set nonconnection.
as “Tag” (the first 8 characters) and “Long tag” (32 *2: Except when Optional code C1 or C2 is specified.
characters) in the amplifier memory.
5. Other factory configurations (HART type) Table B. Fieldbus type
Specifying option code CA will allow further
configuration at factory. Input sensor type *1 “Pt100” or as specified in order
Descriptor (up to 16 characters) Wire connection “3-wire system” or as specified in
6. Sensor back up (For RTD) *1 order
Select ‘DISABLE’ or ‘ENABLE’. Calibration range *1 “0 to 100” or as specified in order
Calibration unit “°C” or as specified in order
Fieldbus type (TC and RTD)
1. Sensor type. Output Scale *1 “0 to 100%”
For RTD and resistance input, specify the number Output mode “Direct”
of wire as well. For sensor input code-2, specify the
Node Address ‘0xF3’ unless otherwise specified in
type for two inputs. (Example: Pt100 3-wire system) (in hexadecimal) order
In this case, AI1 (Sensor1) value and AI2 (Sensor2)
Operation functional ‘BASIC’, or as specified in order
value are alternately displayed on the integral
Class
indicator with sensor back up DISABLE.
2. Calibration range (XD_SCALE) Sensor backup *2 ‘DISABLE’ or as specified in order
For sensor input code-2, specify the range for two Tag Number “Blank” or as specified in order
inputs. (Tag plate)
3. Units of calibration range: Software Tag ‘TT1001’ unless otherwise specified
Specify only one unit from the table, ‘Settings when (PD_TAG) in order.
shipped.’ For sensor input code-2, specify the unit *1: For sensor input code-2, sensor 2 is set in
for two inputs. nonconnection.
4. Output mode (L_TYPE) *2: Channel settings of AI function blocks depend on
Select ‘Direct’ or ‘Indirect .’ sensor backup setting.
5. Output scale (OUT_SCALE) Disable: AI1= Sensor1,
AI2= If Sensor2 type is specified then
For sensor input code-2, specify the scale for two
Sensor2 else Terminal temperature
inputs. Enable: AI1= Backup temperature,
AI2= Terminal temperature

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C50G01-01EN Mar. 2, 2018-00
Subject to change without notice.
ATTACHMENT-4

CATALOGUE OF THERMOWELL
Thermowells

Thermowells
Type TW.FL/TW10
WIKA Datasheet TW.FL/TW10

Applications

Thermowells for temperature instruments are recommended


for all process systems where pressure, velocity or viscous,
abrasive and corrosive materials are present individually or
in combination. A properly selected thermowell will protect
the temperature instrument from possible damage resulting
from these process variables.

Furthermore, a thermowell permits removal of the tempera-


ture instrument for replacement, repair or testing without
affecting the process media or the system.

Standard Features
Process connections
Flanged

Instrument connection Thermowell with flange, model TW10


½” NPSM Standard

Bore diameter
.260”, .385”

Materials
Brass, AISI 304, AISI 316
(Other materials available upon request)

Surface finish
Brass: 60-100 Ra
AISI 304 & AISI 316: 60-100 Ra
Sanitary (AISI 304 & AISI 316):16-20 Ra

Ordering Information
See current WIKA Catalog or WIKA Price List for ordering
information

WIKA Datasheet TW.FL/TW10 · 6/2012 Page 1 of 5


R
WIKA type FL2T & FL3T (.260 bore, .385 bore)

Type FL2T and FL3T Flange sizes available:


Type Type
1", 1½", 2"
FLT2T FLT3T
U Dim A Dim Q Dim
2” 4” Flange ratings available:
5/8” 49/64”
150#
4” 6” 300#
7” 9” 600#
10” 12” 900#
1500#
13” 15” 2500#
16” 18”
22” 24”
Flange facings available:
Flat Face (FF)
Raised Face (RF)
Flange Minimum head lengths flange size Ring Joint (RTJ)
Rating 1” 1½” 2” 2½” 3” 4”
150# 2.25” 2.25” 2.25” 2.25” 2.25” 2.25”
300# 2.25” 2.25” 2.25” 2.25” 3.25” 3.25”
400# 2.25” 2.25” 3.25” 3.25” 3.25” 3.25”
600# 2.25” 2.25” 3.25” 3.25” 3.25” 3.25”
900# 3.25” 3.25” 3.25” 3.25” 3.25” 3.25”
1500# 3.25” 3.25” 3.25” 3.25” 3.25” 3.25”
2500# 3.25” 3.25” 4.25” 4.25” 4.25” 4.25”

NOTES:
1. Flanges are manufactured in accordance with ANSI B16.5.
2. Raised face flange supplied as standard ANSI serrated.
125 RMS smooth face available.
3. Full penetration welds standard.
4. Wrench flats used on wells with a stem length of more than 21” long.
5. Bar diameter on flanged wells: 1.125” thru 600# rating.
1.375” for and over 900#.

Page 2 of 5 WIKA Datasheet TW.FL/TW10 · 6/2012


TW-10-
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

1 - Welding options (W) 5 - Pressure rating 7 - Instrument connection


Code D 150 psig UD ½ NPT female
F Full penetration welded E 300 psig UF ½ NPT-CSA female
P Partial penetration, fillet F 400 psig GF ½ NPSM
a =3 mm (minimum)
H 600 psig UE ¾ NPT female
R Partial penetration, fillet
a = 6 mm (minimum) J 900 psig GD G ½ B male
S Screwed and welded K 1,500 psig TD G ½ male
B Screwed and welded both L 2,500 psig GE G ¾ B male
side of flange M PN 6 TE G ¾ male
2 - Thermowell style P PN 16 SD M14 x 1.5 female
A Tapered Q PN 40 SG M18 x 1.5 female
B Straight R PN 63 SI M20 x 1.5 female
C Stepped S PN 64 MC M20 x 1.5 male
T PN 100 MK M24 x 1.5 female
3 - Unit of measure
MJ M24 x 1.5 male
I Imperial 6 - Flange face
TH M27 x 2.0 female
M Metric A FF (flat face)
MD M27 x 2.0 male
B RF (raised face)
4 - Flange size (Fs)
C RTJ (ring type joint) 8- Pipe schedule / Intern. nozzle dia.
A ASME 1”
D RFSF (raised face smooth 2 Schedule 40 (Standard N.A.)
B ASME 1 1/4” finish)
3 Schedule 80
C ASME 1 1/2” E DIN 2526 Form C
1 Schedule 160
D ASME 2” F DIN 2526 Form E
4 Schedule XXS
E ASME 2 1/2” G DIN 2526 Form N
N WIKA (Standard Germany)
F ASME 3” H DIN 2526 Form F
G ASME 4” K EN 1092-1 Form B1 9 - Insertion length (U)
I EN 1092-1 DN 25 L EN 1092-1 Form B2 Please specify; maximum 62”
***** 1575 mm) (e.g. 8.5” = 08500)
K EN 1092-1 DN 40 M EN 1092-1 Form C (e.g. 240 mm = 00240)
L EN 1092-1 DN 50 N EN 1092-1 Form D
N EN 1092-1 DN 80 10- Head length (H)
P EN 1092-1 DN 100 01770 1.77”
S DIN 2526/2527 DN 25 02250 2.25”
U DIN 2526/2527 DN 40 02360 2.36”
W DIN 2526/2527 DN 50 03250 3.25”
Y DIN 2526/2527 DN 80 04250 4.25”
1 DIN 2526/2527 DN 100 05250 5.25”
00045 45 mm
00057 57 mm
00060 60 mm
00083 83 mm
00102 102 mm
00108 108 mm
00133 133 mm
Please specify (e.g. 3.5” =
***** 03500) (e.g. 84 mm = 00084)

WIKA Datasheet TW.FL/TW10 · 6/2012 Page 3 of 5


TW-10-
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

11 - Flange material 12 - Bar material 13 - Bar diameter (Bd)


G3 316/316L SS G3 316/316L SS M 1.000” (25.4 mm)
G1 304/304L SS G1 304/304L SS N 1.125” (28.6 mm)
F1 Carbon steel A105 F1 Carbon steel A105 O 1.250” (31.8 mm)
G5 310 SS G5 310 SS P 1.315”(33.4 mm)
G6 321 SS G6 321 SS R 1.375” (34.9 mm)
G8 347 SS G8 347 SS S 1.500” (38.1 mm)
G4 316H SS G4 316H SS U 1.750” (44.5 mm)
G2 304H SS G2 304H SS W W 2.000” (50.8 mm)
H1 Carbon steel F11 H1 Carbon steel F11 X 2.250” (57.2 mm)
H2 Carbon steel F22 H2 Carbon steel F22 Y 2.500” (63.5 mm)
H3 Carbon steel F5 H3 Carbon steel F5 G 2.750”` (69.9 mm)
H4 Carbon steel F9 H4 Carbon steel F9 D 30 mm (1.181”)
H5 Carbon steel F91 H5 Carbon steel F91 A 32 mm (1.260”)
B1 Inconel® 600 B1 Inconel® 600 E 34 mm (1.339”)
B2 Inconel® 601 B2 Inconel® 601
14 - Bore size (B)
B3 Inconel® 625 B3 Inconel® 625
E 0.244” (6.2 mm)
C1 Incoloy 800H/HT C1 Incoloy 800H/HT
A 0.260 ” (6.6 mm)
C2 Incoloy 825 C2 Incoloy 825
F 0.276” (7.0 mm)
L7 Titanium grade II (3.7035) A5 Titanium grade II
G 0.323” (8.2 mm)
D1 Monel® 400 D1 Monel® 400
M 0.335” (8.5 mm)
E1 Nickel 200 E1 Nickel 200
N 0.354” (9.0 mm)
E2 Nickel 201 E2 Nickel 201
B 0.385” (9.8 mm)
A2 Hastelloy® C-276 A2 Hastelloy® C-276
P 0.402” (10.2 mm)
A1 Hastelloy® B-2 A1 Hastelloy® B-2
R 0.433” (11.0 mm)
A3 Hastelloy® C-4 A3 Hastelloy® C-4
S 0.480” (12.2 mm)
I1 410 SS I1 410 SS
C 0.512” (13 mm)
L5 1.4571 SS I2 446 SS
D 0.702” (17.8 mm)
L6 1.4462 SS A4 Hastelloy® C-22
L1 Carbon steel 1.7335 (13CrMo44) 15 - Root diameter (Q)
L6 1.4462 SS
L4 Carbon steel 1.5416 (15Mo3/16Mo3) 0500 0.500”
L5 1.4571 SS
L2 Carbon steel 1.7380 (10CrMo910) 0750 0.750”
L1 Carbon steel 1.7335 (13CrMo44)
L3 Carbon steel 1.0460 (C22.8) 0875 0.875”
L4 Carbon steel 1.5415
S1 Hastelloy® C-4 / Stainless steel (15Mo3/16Mo3) 1000 1.000”
L2 Carbon steel 1.7380 (10CrMo910) 1063 1.063”
S2 Hastelloy® C-276 / Stainless steel
L3 Carbon steel 1.0460 (C22.8) 0190 19 mm
S3 Monel® 400 / Stainless steel
F2 Carbon steel 1018l 0220 22 mm
S4 Nickel 200 / Stainless steel
0250 25 mm
S5 Nickel 201 / Stainless steel
0270 27 mm
S6 Titanium grade II / Stainless steel
**** Please specify (e.g. 1.5” =
1500) (e.g. 24 mm = 0240)

Page 4 of 5 WIKA Datasheet TW.FL/TW10 · 6/2012


TW-10-
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

16 - Tip diameter (V)


0500 500”
0625 0.625”
0750 0.750”
1000 1.000”
0127 12.7 mm
0160 16 mm
0190 19 mm
0220 22 mm
0250 25 mm
**** Please specify (e.g. 1.5” =
1500) (e.g. 24 mm = 0240)

17 - RTD / TC / Thermometer assembly


1A TR10 Industrial RTD assembly
1B TC10 Industrial TC assembly
1C TR15 Remote RTD assembly
1D TC15 Remote TC assembly
1F TR75 DiwiTherm®
YY Dial thermometer
(Bimetal / Gas actuated)
ZZ Without

18 - Certificates
1 Quality certificates
Z Without

19 - Additional order details


T Additional text
Z Without

WIKA Datasheet TW.FL/TW10 · 6/2012 Page 5 of 5

WIKA Instrument Corporation


1000 Wiegand Boulevard
Lawrenceville, GA 30043-5868
Tel: 888-WIKA-USA • 770-513-8200
Fax: 770-338-5118
E-Mail: [email protected]
www.wika.com
ATTACHMENT-5

WAKE FREQUENCY CALCULATION


WIKA Instrumentation PTE. LTD.

Customer: PT.PERTAMINA GAS Name: Lind Lim


WIKA Instrumentation PTE. LTD.

13 Kian Teck Crescent


Project: Pembangunan Pipa Gas Duri Dumai (PGDD).
Date: 3rd April 2018
628878 Singapore

Singapore
Ref. -No.: WFC-QU00060210-Rev.4
phone: +65 6844 5506
fax: +65 6844 5507
Calculation email: [email protected]
Tag-No.: TIT-001A/TW-001A
result:
good web: www.wika.com.sg

Thermowell Calculation Program v2.7.1


Results to ASME PTC 19.3 TW - 2016
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
Description Description
WIKA / ASME WIKA / ASME
Result: Process data: 1

Result Eval. good Temperature T 100.00 °F

Frequency ratio r 0.39 fw/fnc Pressure P 363.00 psig

Ratio limit fw/fnc rmax_ 0.40 Max.velocity v 80.00 ft/s

Safety fatigue dyn 26.53 / Med.density rho 1.24 lb/ft3

Safety bending stat 99.53 / Dyn. viscosity my 0.012 mPa s

Safety pressure Sp 23.99 /

Optimized length (rmax) Uopt / Lopt in.

Note code /
Pipe data:
Inner diameter Di in.

Shielded length SL / Lo in.

Usable nozzle length *) UNL / 5.900 in.

Nozzle inner diameter *) NID / 0.956 in.


*) for support collar
Thermowell sketch

Thermowell data:
WIKA model TW10 Name

Connection flanged
Shape straight Name

Insertion length U/L 5.709 in.

Optimized length Uopt / in.

Stepped length US / Ls 0.000 in.

Step radius RS / rB 0.000 in.

Root radius RQ / rA 0.118 in.


2c wm straight TW10
Bore diameter B / db 0.260 in.

Root diameter Q/A 0.827 in.

Tip diameter V/B 0.827 in.

Tip thickness Tt / Tt 0.252 in.

Material data:
Grade mat 316 Name

Spec. weight D(T) 0.289 lb/in3

Youngs modul E(T) 28115.4 ksi

Factor for temp. FT 0.986 /

Fatigue strength Sf(T) 8975.9 psi

Max.all.stress 1.5S(T) 30000.0 psi

Press. strength S(T) 20000.0 psi

Fatigue class class B

WIKA has made every reasonable attempt to validate the calculation procedure contained in this spread sheet, however, responsibility for validation rests solely with the user.
This WIKA ASME PTC 19.3 TW - 2016 spread sheet copyright © 2018 (compatible with Excel 2007/2010) is intended to assist the experienced designer of thermowells and should
not be considered as a replacement for professional engineering.The end user is responsible to assure that the calculation method is compatible to the process conditions.
For further information see Operation Instruction.
WIKA Instrumentation PTE. LTD.

Customer: PT.PERTAMINA GAS Name: Lind Lim


WIKA Instrumentation PTE. LTD.

13 Kian Teck Crescent


Project: Pembangunan Pipa Gas Duri Dumai (PGDD).
Date: 3rd April 2018
628878 Singapore

Singapore
Ref. -No.: WFC-QU00060210-Rev.4
phone: +65 6844 5506
fax: +65 6844 5507
Calculation email: [email protected]
Tag-No.: TIT-001B/TW-001B
result:
good web: www.wika.com.sg

Thermowell Calculation Program v2.7.1


Results to ASME PTC 19.3 TW - 2016
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
Description Description
WIKA / ASME WIKA / ASME
Result: Process data: 1

Result Eval. good Temperature T 100.00 °F

Frequency ratio r 0.39 fw/fnc Pressure P 363.00 psig

Ratio limit fw/fnc rmax_ 0.40 Max.velocity v 80.00 ft/s

Safety fatigue dyn 26.53 / Med.density rho 1.24 lb/ft3

Safety bending stat 99.53 / Dyn. viscosity my 0.012 mPa s

Safety pressure Sp 23.99 /

Optimized length (rmax) Uopt / Lopt in.

Note code /
Pipe data:
Inner diameter Di in.

Shielded length SL / Lo in.

Usable nozzle length *) UNL / 5.900 in.

Nozzle inner diameter *) NID / 0.956 in.


*) for support collar
Thermowell sketch

Thermowell data:
WIKA model TW10 Name

Connection flanged
Shape straight Name

Insertion length U/L 5.709 in.

Optimized length Uopt / in.

Stepped length US / Ls 0.000 in.

Step radius RS / rB 0.000 in.

Root radius RQ / rA 0.118 in.


2c wm straight TW10
Bore diameter B / db 0.260 in.

Root diameter Q/A 0.827 in.

Tip diameter V/B 0.827 in.

Tip thickness Tt / Tt 0.252 in.

Material data:
Grade mat 316 Name

Spec. weight D(T) 0.289 lb/in3

Youngs modul E(T) 28115.4 ksi

Factor for temp. FT 0.986 /

Fatigue strength Sf(T) 8975.9 psi

Max.all.stress 1.5S(T) 30000.0 psi

Press. strength S(T) 20000.0 psi

Fatigue class class B

WIKA has made every reasonable attempt to validate the calculation procedure contained in this spread sheet, however, responsibility for validation rests solely with the user.
This WIKA ASME PTC 19.3 TW - 2016 spread sheet copyright © 2018 (compatible with Excel 2007/2010) is intended to assist the experienced designer of thermowells and should
not be considered as a replacement for professional engineering.The end user is responsible to assure that the calculation method is compatible to the process conditions.
For further information see Operation Instruction.

You might also like