0% found this document useful (0 votes)
168 views

Testing Session TOFD EECI - Eurosonic

This document outlines a time-of-flight diffraction (TOFD) testing session. It is divided into three parts that cover image quality, identification of indications, and sizing. The identification section shows various TOFD tests performed on materials with thicknesses ranging from 15 to 50 mm, and specifies the ultrasonic parameters used in each test.

Uploaded by

Rupam Baruah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
168 views

Testing Session TOFD EECI - Eurosonic

This document outlines a time-of-flight diffraction (TOFD) testing session. It is divided into three parts that cover image quality, identification of indications, and sizing. The identification section shows various TOFD tests performed on materials with thicknesses ranging from 15 to 50 mm, and specifies the ultrasonic parameters used in each test.

Uploaded by

Rupam Baruah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 47

TOFD Course 2008 PBE

TIME ‐ OF ‐ FLIGHT DIFFRACTION


TESTING SESSION 
(Level I and II)
(Level I and II) 

Name :
Surname :
Company :
Date :

Page 1
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
TOFD Course 2008 PBE

CONTENTS

PART I – Images quality
PART II – Identification
PART II – Classification
PART III – Sizing

Page 2
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
TOFD Course 2008 PBE

PART I

Images quality
Images quality

Page 3
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Images quality TOFD Course 2008 PBE

Page 4
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Images quality TOFD Course 2008 PBE

Page 5
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
TOFD Course 2008 PBE

PART II

Identification of indications
Identification of indications

Page 6
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Identification of indications TOFD Course 2008 PBE

TOFD testing on 40 mm thick

Ultrasonic parameters: longitudinal wave velocity 5920 m/s


Transmitter probe: frequency 5 MHz, wedge angle 60°, wave mode longitudinal.
Receiver probe: frequency 5 MHz, wedge angle 60°, wave mode longitudinal.

Page 7
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Identification of indications TOFD Course 2008 PBE

TOFD testing on 40 mm thick

Ultrasonic parameters: longitudinal wave velocity 5920 m/s


Transmitter probe: frequency 5 MHz, wedge angle 70°, wave mode longitudinal.
Receiver probe: frequency 5 MHz, wedge angle 70°, wave mode longitudinal.

Page 8
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Identification of indications TOFD Course 2008 PBE

TOFD testing on 19.5 mm thick.

Ultrasonic parameters: longitudinal wave velocity 5920 m/s


Transmitter probe: frequency 10 MHz, wedge angle 70°, wave mode longitudinal.
Receiver probe: frequency 10 MHz, wedge angle 70°, wave mode longitudinal.

Page 9
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Identification of indications TOFD Course 2008 PBE

TOFD testing on 18 mm thick.

Ultrasonic parameters: longitudinal wave velocity 5920 m/s


Transmitter probe: frequency 10 MHz, wedge angle 60°, wave mode longitudinal.
Receiver probe: frequency 10 MHz, wedge angle 60°, wave mode longitudinal.

Page 10
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Identification of indications TOFD Course 2008 PBE

TOFD testing on 15 mm thick .

Ultrasonic parameters: longitudinal wave velocity 5920 m/s


Transmitter probe: frequency 10 MHz, wedge angle 70°, wave mode longitudinal.
Receiver probe: frequency 10 MHz, wedge angle 70°, wave mode longitudinal.

Page 11
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Identification of indications TOFD Course 2008 PBE

TOFD testing on 15 mm thick .

Ultrasonic parameters: longitudinal wave velocity 5920 m/s


Transmitter probe: frequency 15 MHz, wedge angle 70°, wave mode longitudinal.
Receiver probe: frequency 15 MHz, wedge angle 70°, wave mode longitudinal.

Page 12
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Identification of indications TOFD Course 2008 PBE

TOFD testing on 50 mm thick .

Page 13
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Identification of indications TOFD Course 2008 PBE

TOFD testing on 15 mm thick .

Page 14
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Identification of indications TOFD Course 2008 PBE

TOFD testing on 25 mm thick .

Page 15
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Identification of indications TOFD Course 2008 PBE

TOFD testing on 25.4 mm thick .

Page 16
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Identification of indications TOFD Course 2008 PBE

TOFD testing on 40 mm thick .

Page 17
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Identification of indications TOFD Course 2008 PBE

TOFD testing on 25.4 mm thick .

Page 18
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Identification of indications TOFD Course 2008 PBE

TOFD testing on 26 mm thick .

Page 19
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
TOFD Course 2008 PBE

PART III

Cl ifi ti
Classification of indication
f i di ti

Page 20
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Classification of indication TOFD Course 2008 PBE

Page 21
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Classification of indication TOFD Course 2008 PBE

Page 22
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Classification of indication TOFD Course 2008 PBE

Page 23
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Classification of indication TOFD Course 2008 PBE

Page 24
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Classification of indication TOFD Course 2008 PBE

Page 25
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Classification of indication TOFD Course 2008 PBE

Page 26
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Classification of indication TOFD Course 2008 PBE

Page 27
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Classification of indication TOFD Course 2008 PBE

Page 28
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Classification of indication TOFD Course 2008 PBE

Page 29
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Classification of indication TOFD Course 2008 PBE

Page 30
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Classification of indication TOFD Course 2008 PBE

Page 31
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Classification of indication TOFD Course 2008 PBE

Page 32
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Classification of indication TOFD Course 2008 PBE

Page 33
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
TOFD Course 2008 PBE

PART IV

Si i
Sizing

Page 34
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Sizing of indication  TOFD Course 2008 PBE

Page 35
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Sizing of indication  TOFD Course 2008 PBE

Page 36
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Sizing of indication  TOFD Course 2008 PBE

Page 37
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Sizing of indication  TOFD Course 2008 PBE

Page 38
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Sizing of indication  TOFD Course 2008 PBE

Page 39
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Sizing of indication  TOFD Course 2008 PBE

Page 40
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Sizing of indication  TOFD Course 2008 PBE

Page 41
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Sizing of indication  TOFD Course 2008 PBE

Page 42
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Sizing of indication  TOFD Course 2008 PBE

Page 43
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Sizing of indication  TOFD Course 2008 PBE

Page 44
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Sizing of indication  TOFD Course 2008 PBE

Page 45
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Sizing of indication  TOFD Course 2008 PBE

Page 46
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI
Sizing of indication  TOFD Course 2008 PBE

Page 47
This document is not to be copied or distributed without prior written permission from Eurosonic or EECI

You might also like