B Rated Test Report
B Rated Test Report
Test Report
GJJ No.1731630 Page 1 of 12
Inspected Units Address Room A2006, No.4, Fufeng Road, Fengtai District, Beijing, China
Contact
Information Zip Code 100070 Phone Number 18001332737
Sampling
Sampling Date 2017.9.1 Factory warehouse
Locations
Sample
Production Date 201708 2017.11.2
Received Date
The sample inspection of LZYB-B3-ZA01 type of anti-riot road blocker, offered by Beijing
ZhuoAoShiPeng Technology Co., Ltd., the test results of all items in accordance with China
Anti-Riot Lifting Barrier Industry Standard(GA/T 1343-2016), meet B3 blocking ability level.
Test
Conclusion
Date: 2018.1.9
Test Report
GJJ No.1731630 Page 2 of 12
Main Equipment
YWX/Q-016 Salt spray test chamber
for Test
The width of barrier blocking part is 3000mm. the maximum rise height is 650mm.
Top steel plate thickness is 25mm.
Sample numbering method: No. 1-2, road blocker, No. 4, salt spray test sample.
Ministry of Public Security Security and Police Electronic Product Quality Testing Center
Test Report
GJJ No.1731630 Page 3 of 12
Sample Judgem
No. Test Items Technical (standard) Requirements Test Results
No. ent
Test Report
GJJ No.1731630 Page 4 of 12
Samp Judge
No. Test Items Technical (standard) Requirements Test Results
le No. ment
Test Energy Vehicle Impact Speed Energy (kJ)
The medium truck was weighted
Code Weight(kg) (km/h)
to 6891 kg and impact the road
Impact A 6800 80 1679 blocker at a speed of 64.7 km/h.
Energy
B 6800 65 1108 After test, the vehicle lost its
After test, the vehicle loses its ability of driving, and the
Impact speed 64.7km /h
barrier should be able to remain blocked situation.
The insulation resistance between the power plug and
the exposed metal parts of the enclosure shall be not
less than 5MΩ after the relative humidity heat of 91%
Insulation to 95%, the temperature of 40°C, and 48 hours, and the
Resistance basic insulation device is not Less than 2MΩ, class III Meet the requirement
Test equipment is not less than 1MΩ. For equipment with an
Test Leakage The leakage current during the operation of Class I and
Current Class II equipment shall comply with the requirements in 0.22mA
Test Table 2 of GB16796-2009. Class Ⅲ no need do this test.
Insulation Between the power plug and the exposed metal parts of
Withstan enclosure, it shall withstand the insulation test of 45Hz
Meet the requirement
d Voltage ~65Hz AC voltage specified in Table 1 of GB16796-2009, and
Test there shall be no breakdown and arcing in 1min.
Ministry of Public Security Security and Police Electronic Product Quality Testing Center
Test Report
GJJ No.1731630 Page 5 of 12
Samp Judge
No. Test Items Technical (standard) Requirements Test Results
le No. ment
Soaking Barrier blocking main structure should be no leakage Barrier blocking structure is placed in
9 Performance phenomenon in the flooding state, and can lift 1 the pool to soak 48h no leakage P
Test normally phenomenon, and can normally lift
10
No Defect
0 < A ≤ 0.1% 9
0.1%< A ≤ 0.2 5% 8
0.25%< A ≤ 0.5% 7
2.5%< A ≤ 5% 4
5%< A ≤ 10% 3
10%< A ≤ 25% 2
25%< A ≤ 50% 1
A > 5 0% 0
Test Report
GJJ No.1731630 Page 6 of 12
Sampl Judge
No. Test Items Technical (standard) Requirements Test Results
e No. ment
Test Report
GJJ No.1731630 Page 7 of 12
LZYB-B3-ZA01 type of road blocker control system and power (hydraulic) system
Ministry of Public Security Security and Police Electronic Product Quality Testing Center
Test Report
GJJ No.1731630 Page 8 of 12
Test Report
GJJ No.1731630 Page 9 of 12
Test Report
GJJ No.1731630 Page 10 of 12
Test Report
GJJ No.1731630 Page 11 of 12
Electrostatic discharge immunity test connection diagram of the device under test
Ministry of Public Security Security and Police Electronic Product Quality Testing Center
Test Report