Level Gauges - SNK/SNKK Series: Specifications

This document provides specifications for SNK/SNKK series level gauges. The level gauges feature a metal shroud with polyamide sight tube, Viton seals, and operate at temperatures up to 194°F. They contain electrical contacts that open or close depending on the minimum fluid level. Dimensions and ordering information are provided for gauges in 127mm, 254mm, and 305mm lengths.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
85 views

Level Gauges - SNK/SNKK Series: Specifications

This document provides specifications for SNK/SNKK series level gauges. The level gauges feature a metal shroud with polyamide sight tube, Viton seals, and operate at temperatures up to 194°F. They contain electrical contacts that open or close depending on the minimum fluid level. Dimensions and ordering information are provided for gauges in 127mm, 254mm, and 305mm lengths.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Level Gauges - SNK/SNKK Series

Specifications
• B lack Epoxy Coated Metal Shroud with Polyamid Sight Tube
• Suitable for Use with Mineral and Petroleum Based Hydraulic Electrical Connections and Functions
Fluids, Lubricants and Gasoline.
• Maximum Operating Temperature 194˚F (90˚C) Contact load:
• Thermometer Calibration from 14˚F (-10˚C) to 176˚F (80˚C) max 10 W (Type C)
• Electrical Contact Made at Minimum Oil Level. max 3 W (Type 0)
• Viton Seals, M12 Bolts Bias-reducing Potential:
• Tightening Torque 70 in-lbs 5O V AC/DC
• Standard Plug Type “C” or “O” per DIN ISO 6952 Current on Contact
max 0,50 A (Type C)
max 0,25 A (Type O)
Options Electrical switch PG 9
• D ial Thermometer Available with 200mm (7.9") or Protection lP65
300mm (11.8") Probe Connection 3 is not
engaged
• 1/2" UNC Bolts Available Contacts Contacts
close at open at
• Special Improved UV Resistant Plastic Sight Tube lower
lower fluid
• Special Lengths Available upon Request level fluid level
• PT100 Sensor for Constant Temperature Feedback
• PT100-D Display Unit for Display and Analysis
of PT100 Signals

Dimensions
SNK 127 SNK 254 SNK 305
mm in mm in mm in
A 56 2.20 56 2.20 56 2.20
B 34.5 1.36 34.5 1.36 34.5 1.36
C 8.2 MAX 0.32 MAX 8.2 MAX 0.32 MAX 8 MAX 0.32 MAX
D 35.1 1.38 35.1 1.38 35.1 1.38
E 49.8 1.96 49.8 1.96 50 1.96
L1 203.2 8.00 330 13.00 363 14.3
L2 127 5.00 254 10.00 305 12.0
T1 200 7.88 200 7.88 200 7.88
T2 302 11.88 302 11.88 302 11.88

Ordering Information
ACCESSORIES

SNK 127 V C T1 12 O60


Type
SNK
Thermo Switch / Sensor
SNKK (see page A31 for details)
(none) Without Thermo Switch / Sensor
O60 TS-SNA / SNK-O-60
Series
O70 TS-SNA / SNK-O-70
127 SNK / SNKK 127 (5")
O80 TS-SNA / SNK-O-80
254 SNK / SNKK 254 (10")
PT TS-SNA / SNK-PT100
305 SNK / SNKK 305 (12")
Banjo Bolts
Seal Material 12 M 12 (Standard with Thermo Option)
V Viton FPM (Standard) 10 M 10
U 1/2" UNC

Switch Function
Thermometer (for size M12 only)
C Make Contact, Closes at Minimum Level (n/o)
O Break Contact, Opens at Minimum Level (n/c) O Without Thermometer
T1 Dial Thermometer With 200mm Probe (7.9")
DD SPDT Contacts, Switches at Minimum Level*
T2 Dial Thermometer With 300mm Probe (11.8")
* SNKK style only ­A30