VAJRA 536: Electric DC Remote Controlled Monitor

VAJRA - 536 is an electric DC remote controlled monitor for fire trucks with a flow capability of up to 4750 LPM. It has rugged bronze construction with horizontal and vertical rotation controls. The monitor can use various nozzles and has provisions for water or water-foam applications. It requires regular inspection and maintenance according to the manual to ensure proper functioning.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
78 views

VAJRA 536: Electric DC Remote Controlled Monitor

VAJRA - 536 is an electric DC remote controlled monitor for fire trucks with a flow capability of up to 4750 LPM. It has rugged bronze construction with horizontal and vertical rotation controls. The monitor can use various nozzles and has provisions for water or water-foam applications. It requires regular inspection and maintenance according to the manual to ensure proper functioning.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

VAJRA 536

ELECTRIC DC REMOTE CONTROLLED MONITOR

VAJRA – 536 is Electric 24V / 12V DC Remote


Controlled Monitor for fire trucks.

Monitor has high flow capability up to 4750 LPM (1250


GPM) . Monitor has rugged construction with corrosion
resistant bronze material, possess several design
features that enables easy operation and minimum
maintenance.

Horizontal and vertical rotation through bronze


swiveling joints with double row of stainless steel ball
bearing. The monitor rotation & elevation is controlled
remotely as well as from the monitor hand wheel.
Model VAJRA – 536 maintain 340° stop to stop
horizontal rotation ability. The monitor have elevation
movement of 90° above horizontal and 45° below
horizontal.

The monitor has provision to mount various nozzles


such as straight stream nozzle, aspirating and non-
aspirating jet & spray/fog nozzle and a foam barrel.

Internally cast in water vanes reduces turbulence and


friction loss, thus increasing nozzle performance. The
design ensures to prevent jet reaction forces from
affecting the horizontal and vertical position of the After few initial successful tests, an authorized person
monitor. must be trained to perform the inspection and testing
of the monitor.
To ensure desired performance, the friction loss
through monitor must be considered while selecting The monitor should be ready for use. To achieve this
the nozzle & the flow through monitor with reference condition, scheduled inspection and maintenance
to available base pressure at inlet of monitor. operation should be performed and it must be recorded
in the maintenance register book indicating the
THE MONITOR CAN BE USED AS WATER OR WATER- requirement or recommendation. The recommended
FOAM MONITOR DEPENDING ON THE NOZZLE. FOR maintenance, procedure must be followed as given in
SELECTION OF FLOW, JET REACH, AND FOR the manual and also as per the local authority having
APPLICATION AS WATER OR WATER FOAM REFER jurisdiction.
MONITOR NOZZLE DATA SHEET.
It is recommended to carry out weekly physical
ELECTRIC POWER PACK inspection of the monitor. The inspection should verify
This consist of Main Control Panel and Remote unit. that no damage has taken place to any component
The Main Control Panel is wall or floor mounted with and the monitor is ready for use.
top cable entry. The panel has following switches and
Carry out functional test every month for the flow,
LED.
regular rotation in horizontal and vertical plane for
- Main switch for power 'On-Off' with LED. the entire operating angle to observe any leakage.
- Remote control selector switch with LED. At least once in three months proper greasing through
- Indicator for 'UP', 'DOWN', 'RIGHT', 'LEFT', 'FOG, 'JET'. grease nipple provided on bearing, worm wheel and
- Monitor motor trip, Nozzle motor trip. worm shaft must be ensured. Each monitor must be
operated with the full flow in accordance to the
- Data communication with Remote panel 'OK' and 'Fail'.
guidelines of the organisation having local jurisdiction.
The logic of the operation is programmed in the Epron
and the panel is microprocessor based. The owner is responsible for maintaining the equipment
in proper operating condition.
The Remote unit is hand held type with Joystick for fog
/ jet, up / down / right / left operation.

INSTALLATION, TESTING & MAINTENANCE


The monitor must be installed and operated carefully
by a trained person, having good knowledge of
equipment.

NOVEMBER, 2007 PAGE 1 OF 4 HD169


TECHNICAL DATA : CAUTION
A trained personnel for fire fighting must use the monitor.
Appropriate guidance & training msut be give to reduce the
MODEL VAJRA – 536 risk of injury. The nozzle must be fixed to the monitor carefully,
mismatched or damaged threads may cause leakage or
SIZE 4 Inch (100 NB) uncouple the nozzle during operation.

Application of water or foam on an electric appliance can


INLET CONNECTION 100 NB ANSI B16.24 FF cause serious injury by way of electrocution, as water is a
conductor of electricity.
OUTLET CONNECTION 4" BSP (M)
The water supply to monitor must be increased gradually. A
MATERIAL Bronze sudden surge of water supply to the monitor must be avoided.

MAXIMUM OPERATING 12 Bar (175 PSI)


PRESSURE

FACTORY HYDRO TEST 500 PSI (35 Bar)


PRESSURE

NOZZLE THRUST Flow in LPM X Pressure


REACTION IN KG. in kg/cm.sq x 0.0228

MONITOR ROTATION 340º stop to stop

MONITOR ELEVATION 90° above horizontal


45° below horizontal

MAXIMUM FLOW 4750 LPM (1250 GPM)

NOZZLE VARSHA - E for Electric


Operation Jet / Fog with
manual override.

ELECTRICALS 24V DC Main Control Panel


& Remote Unit with
Joystick operation.for safe
area operation

NOVEMBER, 2007 PAGE 2 OF 4 HD169


VAJRA 536 - ELECTRIC DC REMOTE CONTROLLED MONITOR

455

8
915

3
470

2 4

1 6

450 295 SIDE VIEW

ELEVATION

PART LIST
ITEM NO. DESCRIPTION MATERIAL SPECIFICATION
1 BASE FLANGE BRONZE IS:318 / ASTM B 62
2 WORM WHEEL BRONZE IS:318 / ASTM B 62
3 WORM SHAFT STAINLESS STEEL
4 TERMINAL BOX GLASSFIBER REINFORCED POLYSTER
5 ELECTRIC MOTOR 24V DC
6 HAND WHEEL CASTIRON
7 HOUSING BRONZE IS:318 / ASTM B 62
8 PRESSURE GAUGE GLYCERENE FILLED 0-16 KG/SQCM
9 JET & SPRAY NOZZLE ALUMINIUM ALLOY IS:617
VARSHA 50E

NOVEMBER, 2007 PAGE 3 OF 4 HD169


ELECRICAL SCHEMATIC DIAGRAM

TO MONITOR
TERMINAL 16 CORE FLEXIBLE CABLE 24 V DC
BOX 4 CORE FLEXIBLE CABLE SUPPLY

JUNCTION MAIN
BOX CONTROL
PANEL

1
1
REMOTE 4 CORE FLEXIBLE CABLE
CONTROL
1
UNIT 1
REMOTE
CONTROL
UNIT

( BY INSTALLER )

LIMITED WARRANTY
Products manufactured by HD FIRE PROTECT PVT.LTD.. are warranted against defects in material and workmanship for a period of Two (2) years from the date of
shipment.
HD's obligation under this warranty is limited to replace or repair the products or its parts, which are shown to HD's examination to be in a defective condition
attributable to HD. No warranty is given for products or components which have been subject, to misuse, improper installation, corrosion, wear and tear,
improper storage, modification or repaired. If the defect attributable to HD cannot be rectified by repair or replacement, then HD may elect to refund the
purchase price of the equipment in complete discharge of its obligation under this Limited Warranty.
IN NO EVENT SHALL HD FIRE PROTECT PVT. LTD. BE LIABLE IN CONTRACT, STRICT LIABILITY OR ANY OTHER LEGAL THEORY, FOR INCIDENTAL, IN-DIRECT, SPECIAL OR
CONSEQUENTIAL DAMAGES, INCLUDING DAMAGES. FOR INJURY TO PERSON OR DEATH OR DAMAGE TO PROPERTY AND OR PENALTIES RESULTING FROM ANY
PRODUCTS OR COMPONENT MANUFACTURED OR ASSEMBLED BY HD. THIS IS LIMITED WARRANTY ONLY. HD DISCLAIMS WITH RESPECT TO THE PRODUCTS ALL IMPLIED
WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE. THERE IS NO WARRANTY OF ANY NATURE MADE BY
HD BEYOND AS STATED ABOVE.
NOTICE :
The equipment presented in this bulletin is to be installed in accordance with the latest publication standards of NFPA or other similar organisations and also
with the provision of government codes or ordinances wherever applicable.
The information provided by us are to the best of our knowledge and belief, and are general guidelines only. Site handling and installation control is beyond our
reach. Hence we give no guarantee for result and take no liability for damages, loss or penalties whatsoever, resulting from our suggestion, information,
recommendation or damages due to our product.
Product development is a continuous programme of HD FIRE PROTECT PVT. LTD. and hence the right to modify any specification without prior notice is reserved
with the company.

C-3/6, THE NANDANVAN IND. ESTATE, L.B.S. MARG, THANE 400 604., INDIA.
PHONES : +(91) 22 2583 5434 2582 6958 2582 6793
FAX : +(91) 22 2581 2524 6796 9049
EMAIL : [email protected] WEBSITE : www.hdfire.com

NOVEMBER, 2007 PAGE 4 OF 4 HD169