Two-Way Slab Design Based On ACI 318-19 Using Finite Element Method Input Data & Design Summary
Two-Way Slab Design Based On ACI 318-19 Using Finite Element Method Input Data & Design Summary
CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Two-Way Slab Design Based on ACI 318-19 using Finite Element Method
ANALYSIS
wc = 150 pcf, (ACI 318-19 19.2.2.1) Ec = wc1.5 33 f'c0.5 = 3321 ksi, (ACI 318-19 19.2.2.1)
te = ( Ie / Ig )1/3 t = (0.25 Ig / Ig )1/3 t = (0.25)1/3 t = 0.63 t= 6.0 in, for Slab only (ACI 318-19 8.3.2, 24.2 & 6)
8.5 in, for Slab & Drop Panel
Joint Du Ru
V n 2 y '
f c Ap 227.10 kips > Pu [Satisfactory]
ANALYSIS
wc = 150 pcf, (ACI 318-19 19.2.2.1) Ec = wc1.5 33 f'c0.5 = 3321 ksi, (ACI 318-19 19.2.2.1)
te = ( Ie / Ig )1/3 t = (0.25 Ig / Ig )1/3 t = (0.25)1/3 t = 0.63 t= 6.0 in, for Slab only (ACI 318-19 8.3.2, 24.2 & 6)
8.5 in, for Slab & Drop Panel
Joint Du
Number in Bending Mu
1 0 Section ft-k/ft
2 0.30 1-2 13.3
3 0.56 2-3 -0.6
4 0.32 3-4 -2.3
5 0 4-5 12.9
6 0.30 1-6 13.2
7 0.47 6 - 11 -0.3
8 0.62 12 - 13 -6.9
9 0.33 13 - 14 -6.8
10 0 7 - 12 -7.3
11 0.54 8 - 13 -5.8
12 0.64 9 - 14 -2.8
13 0.68
14 0.34 DETERMINE FACTORED LOAD (ACI 318-19 5.3)
15 0 wu = 1.2 DL + 1.6 LL = 0.292 ksf
16 0.30
17 0.47 DETERMINE FLEXURE CAPACITY (ACI 318-19 7.6.1.1, 8.6.1.1, & 22)
18 0.62
19 0.33 Top Bar Bot. Layer Bot. Bot. Layer Top
20 0 6 # 6 @ 12" o.c. 5 @ 18" o.c. 5 @ 18" o.c.
21 0 d (in) 8.88 8.44 7.81
22 0.30 As (in2/ft) 0.44 0.21 0.21
23 0.56 As, min (in2/ft) 0.36 0.21 0.21
24 0.32 a (in) 0.86 0.41 0.41
25 0 f Mn (ft-k/ft) 16.7 7.7 7.1