Two-Way Slab Design Based On ACI 318-19 Using Finite Element Method Input Data & Design Summary

This document provides a summary of the design of a two-way concrete slab using finite element analysis and based on ACI 318-19 code provisions. It includes the input parameters of the slab geometry, material strengths, loads and reinforcement details. The analysis determined bending moments, deflections and punching shear capacity which were all verified to be adequate based on the code design requirements. Reinforcement sizes and spacing in the top and bottom of the slab were designed to satisfy the bending and shear demands at critical locations.

Uploaded by

Chrispin Barnigo
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
506 views

Two-Way Slab Design Based On ACI 318-19 Using Finite Element Method Input Data & Design Summary

This document provides a summary of the design of a two-way concrete slab using finite element analysis and based on ACI 318-19 code provisions. It includes the input parameters of the slab geometry, material strengths, loads and reinforcement details. The analysis determined bending moments, deflections and punching shear capacity which were all verified to be adequate based on the code design requirements. Reinforcement sizes and spacing in the top and bottom of the slab were designed to satisfy the bending and shear demands at critical locations.

Uploaded by

Chrispin Barnigo
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 4

PROJECT : PAGE :

CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Two-Way Slab Design Based on ACI 318-19 using Finite Element Method

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH
fc' = 3 ksi, (21 MPa)
REBAR YIELD STRESS
fy = 60 ksi, (414 MPa)
COLUMN SPACING EACH WAY
L = 24 ft, (7.32 m)
B = 24 ft, (7.32 m)
SLAB THICKNESS
t = 9.5 in, (241 mm)
BENDING DROP PANEL THK. (12.0 ft x 12.0 ft)
tdrop = 2.5 in, (64 mm)
PUNCHING CAP THICKNESS
tcap = 0 in, (0 mm)
COLUMN SIZE (SHORT EDGE)
c= 24 in, (610 mm)
DEAD LOAD & SELF WT
DL = 150 psf, (7.2 kPa)
LIVE LOAD
LL = 70 psf, (3.4 kPa)

TOP BARS AT COLUMNS EACH WAY


6 # 6 @ 12 in, (305 mm), o.c.
x 8.0 ft. long, with 0.75 in, (19 mm), cover
(All top bars to column strip suggested, if column strip & middle strip used.)

BOTTOM LAYER BOTTOM BARS


# 5 @ 18 in, (457 mm), o.c. THE DESIGN IS ADEQUATE.
BOTTOM LAYER TOP BARS
# 5 @ 18 in, (457 mm), o.c.
with 0.75 in, (19 mm), bottom concrete cover
(75% total bottom bars to middle strip & 25% to column strip suggested, if column strip & middle strip used.)

ANALYSIS
wc = 150 pcf, (ACI 318-19 19.2.2.1) Ec = wc1.5 33 f'c0.5 = 3321 ksi, (ACI 318-19 19.2.2.1)
te = ( Ie / Ig )1/3 t = (0.25 Ig / Ig )1/3 t = (0.25)1/3 t = 0.63 t= 6.0 in, for Slab only (ACI 318-19 8.3.2, 24.2 & 6)
8.5 in, for Slab & Drop Panel
Joint Du Ru

Number in kips Bending Mu


1 0 42.05 Section ft-k/ft
2 0.29 1-2 12.9
3 0.53 2-3 -0.2
4 0.29 1-6 12.9
5 0 42.05 6 - 11 -0.2
6 0.29 3-8 -0.5
7 0.46 8 - 13 -6.0
8 0.64 11 - 12 -0.5
9 0.46 12 - 13 -6.0
10 0.29
11 0.53
12 0.64
13 0.75
14 0.64 DETERMINE FACTORED LOAD (ACI 318-19 5.3)
15 0.53 wu = 1.2 DL + 1.6 LL = 0.292 ksf
16 0.29
17 0.46 DETERMINE FLEXURE CAPACITY (ACI 318-19 7.6.1.1, 8.6.1.1, & 22)
18 0.64
19 0.46 Top Bar Bot. Layer Bot. Bot. Layer Top
20 0.29 6 # 6 @ 12" o.c. 5 @ 18" o.c. 5 @ 18" o.c.
21 0 42.05 d (in) 10.13 8.44 7.81
22 0.29 As (in2/ft) 0.44 0.21 0.21
23 0.53 As, min (in2/ft) 0.41 0.21 0.21
24 0.29 a (in) 0.86 0.41 0.41
25 0 42.05 fMn (ft-k/ft) 19.2 7.7 7.1

CHECK FLEXURE CAPACITY


Mu,Top = Max( Mu,1-2 , Mu,1-6 ) = 12.9 ft-k/ft < fMn = 19.2 ft-k/ft [Satisfactory]
Mu,Bot,Bot = - Min( Mu,8-13 , Mu,12-13 ) = 6.0 ft-k/ft < fMn = 7.7 ft-k/ft [Satisfactory]
Mu,Bot,Top = - Max( Mu,8-13 , Mu,12-13 ) = 6.0 ft-k/ft < fMn = 7.1 ft-k/ft [Satisfactory]
(cont'd)
CHECK LIVE LOAD DEFLECTION (ACI 318-19 Table 24.2.2)
DLL = Du,Max LL / (1.2 DL + 1.6 LL) = 0.18 in < L / 360 = 0.80 in
[Satisfactory]

CHECK LONG-TERM DEFLECTION (ACI 318-19 24.2.4)


D3DL + LL = Du,Max (3DL + LL) / (1.2 DL + 1.6 LL) = 1.33 in < L / 180 = 1.60 in
[Satisfactory]

CHECK COLUMN PUNCHING CAPACITY (ACI 318-19 8.4 & 8.5)


Pu = 4 Ru,max = 168.2 kips (See Punching.xls Software for More Information.)

V n   2  y   '
f c Ap  227.10 kips > Pu [Satisfactory]

where f = 0.75 (ACI 318-19 21.2)


bc = 1.00
d= 10.1 in
b0 = 4c+4d= 136.5 in
Ap = b0 d = 1382.1 in2
y= MIN(2 , 4 / bc , 40 d / b0) = 2.0
PROJECT : PAGE :
CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Two-Way Slab Design Based on ACI 318-19 using Finite Element Method

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH
fc' = 3 ksi, (21 MPa)
REBAR YIELD STRESS
fy = 60 ksi, (414 MPa)
COLUMN SPACING EACH WAY
L = 24 ft, (7.32 m)
B = 24 ft, (7.32 m)
SLAB THICKNESS
t = 9.5 in, (241 mm)
BENDING DROP PANEL THK. (12.0 ft x 12.0 ft)
tdrop = 2.5 in, (64 mm)
PUNCHING CAP THICKNESS
tcap = 0 in, (0 mm)
DEAD LOAD & SELF WT
DL = 150 psf, (7.2 kPa)
LIVE LOAD
LL = 70 psf, (3.4 kPa)

TOP BARS AT COLUMNS EACH WAY


6 # 6 @ 12 in, (305 mm), o.c.
x 8.0 ft. long, with 2 in, (51 mm), cover
(All top bars to column strip suggested, if column strip & middle strip used.)

BOTTOM LAYER BOTTOM BARS


# 5 @ 18 in, (457 mm), o.c. THE DESIGN IS ADEQUATE.
BOTTOM LAYER TOP BARS
# 5 @ 18 in, (457 mm), o.c.
with 0.75 in, (19 mm), bottom concrete cover
(75% total bottom bars to middle strip & 25% to column strip suggested, if column strip & middle strip used.)

ANALYSIS
wc = 150 pcf, (ACI 318-19 19.2.2.1) Ec = wc1.5 33 f'c0.5 = 3321 ksi, (ACI 318-19 19.2.2.1)
te = ( Ie / Ig )1/3 t = (0.25 Ig / Ig )1/3 t = (0.25)1/3 t = 0.63 t= 6.0 in, for Slab only (ACI 318-19 8.3.2, 24.2 & 6)
8.5 in, for Slab & Drop Panel
Joint Du

Number in Bending Mu
1 0 Section ft-k/ft
2 0.30 1-2 13.3
3 0.56 2-3 -0.6
4 0.32 3-4 -2.3
5 0 4-5 12.9
6 0.30 1-6 13.2
7 0.47 6 - 11 -0.3
8 0.62 12 - 13 -6.9
9 0.33 13 - 14 -6.8
10 0 7 - 12 -7.3
11 0.54 8 - 13 -5.8
12 0.64 9 - 14 -2.8
13 0.68
14 0.34 DETERMINE FACTORED LOAD (ACI 318-19 5.3)
15 0 wu = 1.2 DL + 1.6 LL = 0.292 ksf
16 0.30
17 0.47 DETERMINE FLEXURE CAPACITY (ACI 318-19 7.6.1.1, 8.6.1.1, & 22)
18 0.62
19 0.33 Top Bar Bot. Layer Bot. Bot. Layer Top
20 0 6 # 6 @ 12" o.c. 5 @ 18" o.c. 5 @ 18" o.c.
21 0 d (in) 8.88 8.44 7.81
22 0.30 As (in2/ft) 0.44 0.21 0.21
23 0.56 As, min (in2/ft) 0.36 0.21 0.21
24 0.32 a (in) 0.86 0.41 0.41
25 0 f Mn (ft-k/ft) 16.7 7.7 7.1

CHECK FLEXURE CAPACITY


Mu,Top = Max( Mu,1-5 , Mu,1-11 ) = 13.3 ft-k/ft < fMn = 16.7 ft-k/ft [Satisfactory]
Mu,Bot,Bot = - Min( Mu ) = 7.3 ft-k/ft < fMn = 7.7 ft-k/ft [Satisfactory]
Mu,Bot,Top = - Max( Mu,12-14 , Mu,7-12 , Mu,8-13 , Mu,9-14 ) = 2.8 ft-k/ft
< fMn = 7.1 ft-k/ft [Satisfactory]

CHECK LIVE LOAD DEFLECTION (ACI 318-19 Table 24.2.2)


D LL = Du,Max LL / (1.2 DL + 1.6 LL) = 0.16 in < L / 360 = 0.80 in
[Satisfactory]

CHECK LONG-TERM DEFLECTION (ACI 318-19 24.2.4)


D3DL + LL = Du,Max (3DL + LL) / (1.2 DL + 1.6 LL) = 1.20 in < L / 180 = 1.60 in
[Satisfactory]