OptiX OSN 1800

Hardware Description 29 Spectrum Analyzer Board

29 Spectrum Analyzer Board

29.1 TNF1OPM8
OPM8: 8-channel optical power monitor board
29.2 TMB1OPM8
OPM8: 8-channel optical power monitor board

29.1 TNF1OPM8
OPM8: 8-channel optical power monitor board

29.1.1 Version Description


The available functional version of the OPM8 board is TNF1.

Version
The following provides the board(s) supported by the device. However, the
availability of the board(s) is subject to PCNs. For PCN information, contact the
product manager at your local Huawei office.
Table 29-1 describes the version of the OPM8 board.

Issue 02 (2020-07-30) Copyright © Huawei Technologies Co., Ltd. 2722


OptiX OSN 1800
Hardware Description 29 Spectrum Analyzer Board

Table 29-1 Version description of the OPM8 board

Product Applicable-System Control Board-Initial Board


Board Version Supported by System Control Board

TNF1OPM8 1800 I&II Compact-TNF3SCC-V100R006C00


1800 V-TNF5UXCM/TNF5UXCME/TNF5XCH-V100R006C00
1800 V-TNZ5UXCMS-V100R006C10
1800 V-TNZ8XCH-V100R009C00SPC700
1800 II Enhanced-TNZ1UXCL-V100R007C10
1800 II Enhanced-TNZ2UXCL-V100R008C00SPC600
1800 II TP-TMB1SCC-V100R019C10SPC600
1800 II Pro-TMK2UXCL-V100R019C10SPC600
1800 V Pro-TMK5SXCH-V100R019C10SPC600

29.1.2 Update Description


This section describes the hardware updates as well as the reasons for the
updates.

Hardware Updates in V100R019C10SPC600


Hardware Update Reason for the Update

The functions of the board The board newly supports the 1800 II TP
are enhanced. TMB1SCC.
The board newly supports the 1800 II Pro
TMK2UXCL.
The board newly supports the 1800 V Pro
TMK5SXCH.

Hardware Updates in V100R019C10SPC300


Hardware Update Reason for the Update

The functions of the board The board newly supports optical-layer ASON.
are enhanced.

29.1.3 Application
The OPM8 board provides eight ports and each of the ports supports optical
power monitoring of up to 80 wavelengths.

For the position of the OPM8 board in the WDM system, see Figure 29-1.

Issue 02 (2020-07-30) Copyright © Huawei Technologies Co., Ltd. 2723


OptiX OSN 1800
Hardware Description 29 Spectrum Analyzer Board

Figure 29-1 Position of the OPM8 board in the WDM system

NOTE

The OPM8 board is usually configured at the receive end. If supervision is required at the
receive and transmit ends, you can configure the OPM8 boards at each end for supervision.

29.1.4 Functions and Features


The OPM8 board is mainly used for optical power monitoring.
For detailed functions and features, refer to Table 29-2.

Table 29-2 Functions and features of the OPM8


Function and Description
Feature

Basic function Provides eight ports and each of the ports supports optical
power monitoring of up to 80 wavelengths.

Monitoring Supports 10 Gbit/s, 100 Gbit/s, and 200 Gbit/s@16QAM


function signal OSNR detection and fixed-wavelength OSNR
detection on the TNF1OPM8 board after the OD license is
installed and OD functions are configured.
Detects optical power of each wavelength and reports to
the system control board.
The results are reported to the SCC and can be displayed
on the NMS.
NOTE
The range of modulation formats supported by a spectrum
analyzer board varies depending on the software version of the
spectrum analyzer module. To determine whether the spectrum
analyzer board supports a modulation format, contact Huawei
engineers for help.

Optical-layer When working with TNZ5UXCMS/TNZ8XCH, the board


ASON supports this function.

Issue 02 (2020-07-30) Copyright © Huawei Technologies Co., Ltd. 2724


OptiX OSN 1800
Hardware Description 29 Spectrum Analyzer Board

29.1.5 Working Principle and Signal Flow


The OPM8 board consists of the 1x8 optical switch, optical power monitor module,
driving and control module, control and communication module, and power
supply module.
Figure 29-2 shows the functional modules and signal flow of the OPM8 board.

Figure 29-2 Functional modules and signal flow of the OPM8 board

Signal Flow
The 1x8 optical switch selects one channel of optical signals from the board it is
connected to, and sends the channel to the optical power monitor module. After
being analyzed and converted, the optical power value is sent to the control and
communication module through a data interface. The control and communication
module reports the value to the system control board and the NMS. The final
optical power detection results are displayed on the NMS.

Module Function
● 1x8 optical switch
Selects one channel of optical signals from the accessed eight channels of
optical signals for optical power detection.

Issue 02 (2020-07-30) Copyright © Huawei Technologies Co., Ltd. 2725


OptiX OSN 1800
Hardware Description 29 Spectrum Analyzer Board

● Optical power monitor module


Monitors channel optical power and reports the data to the driving and
control module.
● Driving and control module
– Drives and scans spectrum.
– Instructs the 1x8 optical switch to select one channel of optical signals for
spectrum analysis.
● Control and communication module
– Controls operations on the board.
– Controls operations on each module of the board.
– Collects information about alarms, performance events, working states
and voltage detection from each functional module on the board.
– Communicates with the system control and communication board.
● Power module
– Converts the DC power supplied by the backplane into the power
required by each module on the board.

29.1.6 Front Panel


There are indicators and interfaces on the front panel of the OPM8 board.

Appearance of the Front Panel


Figure 29-3 shows the front panel of the OPM8 board.

Figure 29-3 Front panel of the OPM8 board

Indicators
Two indicators are present on the front panel:
● Board hardware status indicator (STAT) - dual-colored (red, and green)
● Service alarm indicator (SRV) - dual-colored (red, and green)
● For details on the indicators, see 31.1 Board Indicators.

Interfaces
Table 29-3 lists the type and function of each interface.

Issue 02 (2020-07-30) Copyright © Huawei Technologies Co., Ltd. 2726


OptiX OSN 1800
Hardware Description 29 Spectrum Analyzer Board

Table 29-3 Types and functions of the interfaces on the OPM8 board

Interface Type Function

IN1-IN8 LC Connects to the "MON" interfaces of other


boards to receive optical signals for analysis.
The interfaces can be connected to eight
"MON" interfaces of other boards at the same
time.

29.1.7 Valid Slots


The OPM8 board occupies two slot.
Table 29-4 shows the slots that can house the OPM8 board.

Table 29-4 Mapping between the slots for housing the OPM8 board and the
logical slots on the NMS

Product Valid Slot Logical Slot

1800 I chassis Slots 1 and 3 Slot 1

1800 II Compact Chassis Slots 1 and 3 Slot 1

Slots 3 and 5 Slot 3

Slots 5 and 7 Slot 5

Slots 2 and 4 Slot 2

Slots 4 and 6 Slot 4

1800 II Enhanced Chassis Slots 1 and 3 Slot 1

Slots 3 and 5 Slot 3

Slots 2 and 4 Slot 2

Slots 4 and 6 Slot 4

1800 V Chassis Slots 1 and 2 Slot 1

Slots 2 and 3 Slot 2

Slots 4 and 5 Slot 4

Slots 5 and 6 Slot 5

Slots 6 and 7 Slot 6

Slots 8 and 9 Slot 8

Slots 9 and 10 Slot 9

Slots 11 and Slot 11


12

Issue 02 (2020-07-30) Copyright © Huawei Technologies Co., Ltd. 2727


OptiX OSN 1800
Hardware Description 29 Spectrum Analyzer Board

Product Valid Slot Logical Slot

Slots 12 and Slot 12


13

Slots 13 and Slot 13


14

Slots 19 and 8 Slot 19

1800 II TP Chassis Slot 1 and 3 Slot 1

Slot 3 and 5 Slot 3

Slot 2 and 4 Slot 2

Slot 4 and 6 Slot 4

Slot 6 and 8 Slot 6

1800 II Pro chassis Slots 1 and 3 Slot 1

Slots 3 and 5 Slot 3

Slots 2 and 4 Slot 2

Slots 4 and 6 Slot 4

1800 V Pro chassis Slots 1 and 3 Slot 1

Slots 3 and 5 Slot 3

Slots 2 and 4 Slot 2

Slots 4 and 6 Slot 4

Slots 7 and 9 Slot 7

Slots 9 and 11 Slot 9

Slots 11 and Slot 11


13

Slots 8 and 10 Slot 8

Slots 10 and Slot 10


12

Slots 12 and Slot 12


14

29.1.8 Optical Interfaces


This topic describes the interface information on the NMS.

Issue 02 (2020-07-30) Copyright © Huawei Technologies Co., Ltd. 2728


OptiX OSN 1800
Hardware Description 29 Spectrum Analyzer Board

Display of Optical Interfaces


The serial numbers of the optical interfaces on the front panel of the board
displayed on the NMS are listed in Table 29-5.

Table 29-5 Serial numbers of the interfaces of the OPM8 board displayed on the
NMS.
Interface on the Panel Interface on the NMS

IN1-IN8 1 to 8

29.1.9 OPM8 Parameters on the NMS


This section lists the board parameters that can be set or queried by using the
NMS.
For parameters of the OPM8, see Table 29-6.

Table 29-6 OPM8 parameters


Field Value Description

Optical Interface/ - Displays the position of the optical


Channel interface.

Optical Interface - Sets and queries the Optical


Name Interface Name.
An Optical Interface Name contains
a maximum of 64 characters. Any
characters are supported.

Optical Enabled, Disabled Sets the optical interface monitoring


Monitoring Default: Enabled state. When the monitoring of an
optical interface is set to Disabled,
the spectrum analyzer board does
not analyze the wavelength on this
interface.

Actual Band - Displays the actual working band of


the board.

Actual Working - Queries the parity of the actual


Band Parity working band of the board.

Issue 02 (2020-07-30) Copyright © Huawei Technologies Co., Ltd. 2729


OptiX OSN 1800
Hardware Description 29 Spectrum Analyzer Board

Field Value Description

Wavelength No Monitor, Sets whether to monitor the current


Monitor Status Monitor wavelength. You are advised to set
Default: No the monitor status of wavelengths
Monitor that bear services to Monitor.
When the parameter is set to
Monitor for a wavelength, the NMS
will report a CHAN_LOS if the NMS
cannot detect the wavelength.
However, when the parameter is set
to No Monitor, the NMS will not
report this alarm.

Monitor Interval 5 to 49995 The Monitor Interval (min.)


(min.) Default: 10 parameter provides an option to set
the supervisory channel for the
current board and to analyze the
time interval of the channel status.

29.1.10 OPM8 Specifications


Specifications include optical specifications, dimensions, weight, and power
consumption.

Optical Specifications
Table 29-7 lists the optical specifications of the OPM8 board.

Table 29-7 Optical specifications of the OPM8 board

Item Unit Value

Operating wavelength range nm 1529 to 1561

Detect range for single channel optical dBm -30 to -10


power

Detected accuracy for optical power dB ±1.5

Channel spacing GHz 50/100

Numbers of optical interface pcs 8

Mechanical Specifications
● Dimensions (H x W x D, unit: mm/in.): 40.1 x 193.8 x 205.9 (1.6 x 7.6 x 8.1)
● Weight: 0.78 kg (1.72 lb.)

Issue 02 (2020-07-30) Copyright © Huawei Technologies Co., Ltd. 2730


OptiX OSN 1800
Hardware Description 29 Spectrum Analyzer Board

Power Consumption
Board Typical Power Consumption (W) Maximum
Power
Consumption
a (W)

TNF1OPM8 4.8 5.3

a: The maximum power consumption is the power consumed by the board


when it works normally under the highest ambient temperature.

29.2 TMB1OPM8
OPM8: 8-channel optical power monitor board

29.2.1 Version Description


The available functional version of the OPM8 board is TMB1.

Version
The following provides the board(s) supported by the device. However, the
availability of the board(s) is subject to PCNs. For PCN information, contact the
product manager at your local Huawei office.

Table 29-8 describes the version of the OPM8 board.

Table 29-8 Version description of the OPM8 board

Product Applicable-System Control Board-Initial Board


Board Version Supported by System Control Board

TMB1OPM8 1800 I&II Compact-TNF3SCC-V100R009C00SPC700


1800 II Enhanced-TNZ1UXCL/TNZ2UXCL-
V100R009C00SPC700
1800 V-TNF5UXCM/TNF5UXCME/TNF5XCH/TNZ5UXCMS/
TNZ8XCH-V100R009C00SPC700
1800 II TP-TMB1SCC-V100R019C10SPC300
1800 II Pro-TMK2UXCL-V100R019C10SPC600
1800 V Pro-TMK5SXCH-V100R019C10SPC600

Substitution Relationship
Table2 lists the substitution relationship for TMB1OPM8 boards.

Issue 02 (2020-07-30) Copyright © Huawei Technologies Co., Ltd. 2731


OptiX OSN 1800
Hardware Description 29 Spectrum Analyzer Board

Table 29-9 Substitution relationship of the TMB1OPM8 boards

Original Substitute Substitution Rules


Board Board

TNF1OPM TMB1OPM8 The TMB1OPM8 board can be created as the


8 F1OPM8 board on the NMS to function as a
TNF1OPM8 board. The NE software must be
upgraded to V100R09C00SPC700 or a later version
for replacement.

NOTE

The TMB1OPM8 board can be used only with the TNF3SCC board on the OSN 1800 I&II
compact devices.

29.2.2 Update Description


This section describes the hardware updates as well as the reasons for the
updates.

Hardware Updates in V100R019C10SPC600


Hardware Update Reason for the Update

The functions of the board The board newly supports the 1800 II Pro
are enhanced. TMK2UXCL.
The board newly supports the 1800 V Pro
TMK5SXCH.

Hardware Updates in V100R019C10SPC300


Hardware Update Reason for the Update

The functions of the board The board newly supports optical-layer ASON.
are enhanced. The board newly support the 1800 II TP TMB1SCC.

Hardware Updates in V100R009C00SPC700


Hardware Update Reason for the Update

Added the TMB1OPM8 A spectrum analyzer Board is added to provide


board. eight ports and each of the ports supports optical
power monitoring of up to 80 wavelengths.

Issue 02 (2020-07-30) Copyright © Huawei Technologies Co., Ltd. 2732


OptiX OSN 1800
Hardware Description 29 Spectrum Analyzer Board

29.2.3 Application
The OPM8 board provides eight ports and each of the ports supports optical
power monitoring of up to 80 wavelengths.

For the position of the OPM8 board in the WDM system, see Figure 29-4.

Figure 29-4 Position of the OPM8 board in the WDM system

NOTE

The OPM8 board is usually configured at the receive end. If supervision is required at the
receive and transmit ends, you can configure the OPM8 boards at each end for supervision.

29.2.4 Functions and Features


The OPM8 board is mainly used for optical power monitoring.

For detailed functions and features, see Table 29-10.

Table 29-10 Functions and features of the OPM8

Function and Description


Feature

Basic function Provides eight ports and each of the ports supports optical
power monitoring of up to 80 wavelengths.

Monitoring Supports 10 Gbit/s, 100 Gbit/s, 200 Gbit/s@16QAM, and


function 200 Gbit/s@e16QAM signal OSNR detection and fixed-
wavelength OSNR detection on the OPM8 board after the
OD license is installed and OD functions are configured.
Detects optical power of each wavelength and reports to
the system control board.
The results are reported to the SCC and can be displayed
on the NMS.

Optical-layer When working with TNZ5UXCMS/TNZ8XCH, the board


ASON supports this function.

Issue 02 (2020-07-30) Copyright © Huawei Technologies Co., Ltd. 2733


OptiX OSN 1800
Hardware Description 29 Spectrum Analyzer Board

29.2.5 Working Principle and Signal Flow


The OPM8 board consists of the 1x8 optical switch, optical power monitor module,
driving and control module, control and communication module, and power
supply module.
Figure 29-5 shows the functional modules and signal flow of the OPM8 board.

Figure 29-5 Functional modules and signal flow of the OPM8 board

Signal Flow
The 1x8 optical switch selects one channel of optical signals from the board it is
connected to, and sends the channel to the optical power monitor module. After
being analyzed and converted, the optical power value is sent to the control and
communication module through a data interface. The control and communication
module reports the value to the system control board and the NMS. The final
optical power detection results are displayed on the NMS.

Module Function
● 1x8 optical switch
Selects one channel of optical signals from the accessed eight channels of
optical signals for optical power detection.

Issue 02 (2020-07-30) Copyright © Huawei Technologies Co., Ltd. 2734


OptiX OSN 1800
Hardware Description 29 Spectrum Analyzer Board

● Optical power monitor module


Monitors channel optical power and reports the data to the driving and
control module.
● Driving and control module
– Drives and scans spectrum.
– Instructs the 1x8 optical switch to select one channel of optical signals for
spectrum analysis.
● Control and communication module
– Controls operations on the board.
– Controls operations on each module of the board.
– Collects information about alarms, performance events, working states
and voltage detection from each functional module on the board.
– Communicates with the system control and communication board.
● Power module
– Converts the DC power supplied by the backplane into the power
required by each module on the board.

29.2.6 Front Panel


There are indicators and interfaces on the front panel of the OPM8 board.

Appearance of the Front Panel


Figure 29-6 shows the front panel of the OPM8 board.

Figure 29-6 Front panel of the OPM8 board

Indicators
Two indicators are present on the front panel:
● Board hardware status indicator (STAT) - red, green, yellow
● Service alarm indicator (SRV) - red, green, yellow
● For details on the indicators, see 31.1 Board Indicators.

Interfaces
Table 29-11 lists the type and function of each interface.

Issue 02 (2020-07-30) Copyright © Huawei Technologies Co., Ltd. 2735


OptiX OSN 1800
Hardware Description 29 Spectrum Analyzer Board

Table 29-11 Types and functions of the interfaces on the OPM8 board

Interface Type Function

IN1-IN8 LC Connects to the "MON" interfaces of other


boards to receive optical signals for analysis.
The interfaces can be connected to eight
"MON" interfaces of other boards at the same
time.

29.2.7 Valid Slots


The OPM8 board occupies two slots.

Table 29-12 shows the slots that can house the OPM8 board.

Table 29-12 Mapping between the slots for housing the OPM8 board and the
logical slots on the NMS

Product Valid Slot Logical Slot

1800 I Compact Slots 1 and 3 Slot 1

1800 II Compact Slots 1 and 3 Slot 1

Slots 3 and 5 Slot 3

Slots 5 and 7 Slot 5

Slots 2 and 4 Slot 2

Slots 4 and 6 Slot 4

1800 II Enhanced Slots 1 and 3 Slot 1

Slots 3 and 5 Slot 3

Slots 2 and 4 Slot 2

Slots 4 and 6 Slot 4

1800 II TP Slots 1 and 3 Slot 1

Slots 3 and 5 Slot 3

Slots 2 and 4 Slot 2

Slots 4 and 6 Slot 4

Slots 6 and 8 Slot 6

1800 V Slots 1 and 2 Slot 1

Slots 2 and 3 Slot 2

Slots 4 and 5 Slot 4

Issue 02 (2020-07-30) Copyright © Huawei Technologies Co., Ltd. 2736


OptiX OSN 1800
Hardware Description 29 Spectrum Analyzer Board

Product Valid Slot Logical Slot

Slots 5 and 6 Slot 5

Slots 6 and 7 Slot 6

Slots 8 and 9 Slot 8

Slots 9 and 10 Slot 9

Slots 11 and 12 Slot 11

Slots 12 and 13 Slot 12

Slots 13 and 14 Slot 13

Slots 19 and 8 Slot 19

1800 II Pro chassis Slots 1 and 3 Slot 1

Slots 3 and 5 Slot 3

Slots 2 and 4 Slot 2

Slots 4 and 6 Slot 4

1800 V Pro chassis Slots 1 and 3 Slot 1

Slots 3 and 5 Slot 3

Slots 2 and 4 Slot 2

Slots 4 and 6 Slot 4

Slots 7 and 9 Slot 7

Slots 9 and 11 Slot 9

Slots 11 and 13 Slot 11

Slots 8 and 10 Slot 8

Slots 10 and 12 Slot 10

Slots 12 and 14 Slot 12

29.2.8 Optical Interfaces


This topic describes the interface information on the NMS.

Display of Optical Interfaces


The serial numbers of the optical interfaces on the front panel of the board
displayed on the NMS are listed in Table 29-13.

Issue 02 (2020-07-30) Copyright © Huawei Technologies Co., Ltd. 2737


OptiX OSN 1800
Hardware Description 29 Spectrum Analyzer Board

Table 29-13 Serial numbers of the interfaces of the OPM8 board displayed on the
NMS.
Interface on the Panel Interface on the NMS

IN1-IN8 1 to 8

29.2.9 OPM8 Parameters on the NMS


This section lists the board parameters that can be set or queried by using the
NMS.
For parameters of the OPM8, see Table 29-14.

Table 29-14 OPM8 parameters


Field Value Description

Optical Interface/ - Displays the position of the optical


Channel interface.

Optical Interface - Sets and queries the Optical


Name Interface Name.
An Optical Interface Name contains
a maximum of 64 characters. Any
characters are supported.

Optical Enabled, Disabled Sets the optical interface monitoring


Monitoring Default: Enabled state. When the monitoring of an
optical interface is set to Disabled,
the spectrum analyzer board does
not analyze the wavelength on this
interface.

Actual Band - Displays the actual working band of


the board.

Actual Working - Queries the parity of the actual


Band Parity working band of the board.

Wavelength No Monitor, Sets whether to monitor the current


Monitor Status Monitor wavelength. You are advised to set
Default: No the monitor status of wavelengths
Monitor that bear services to Monitor.
When the parameter is set to
Monitor for a wavelength, the NMS
will report a CHAN_LOS if the NMS
cannot detect the wavelength.
However, when the parameter is set
to No Monitor, the NMS will not
report this alarm.

Issue 02 (2020-07-30) Copyright © Huawei Technologies Co., Ltd. 2738


OptiX OSN 1800
Hardware Description 29 Spectrum Analyzer Board

Field Value Description

Monitor Interval 5 to 49995 The Monitor Interval (min.)


(min.) Default: 10 parameter provides an option to set
the supervisory channel for the
current board and to analyze the
time interval of the channel status.

29.2.10 OPM8 Specifications


Specifications include optical specifications, dimensions, weight, and power
consumption.

Optical Specifications

Table 29-15 Optical specifications of the OPM8 board


Item Unit Value

Operating wavelength range nm 1529 to 1561

Detect range for single channel optical dBm -30 to -10


power

Detected accuracy for optical power dB ±1.5

Channel spacing GHz 50/100

Numbers of optical interface pcs 8

Mechanical Specifications
● Dimensions (H x W x D, unit: mm/in.): 40.1 x 193.8 x 205.9 (1.6 x 7.6 x 8.1)
● Weight: 0.8 kg (1.76 lb.)

Power Consumption
Board Typical Power Consumption (W) Maximum
Power
Consumption
a (W)

TMB1OPM8 7 8

a: The maximum power consumption is the power consumed by the board


when it works normally under the highest ambient temperature.