Alicat Part Number Decoder

Elements usually present:

MCRWD-40SLPM-TFTRD-DB15-MODBUS-485-54X54-SAE-EPDM-CC
Primary Instrument
Types Communications Options Build Options
L Liquid flow meter Display Options [no notation] RS-232 over 8-pin mini-DIN [no notation] NPT threads, Viton elastomers
M Gas mass flow meter D Backlit monochrome 485 RS-485 protocol 30PSIA Low-range sensor for gas flow
P Pressure gauge O No display DB9x 9-pin D-sub with x pinout #BSP British Standard Pipe threads
RD Backlit monochrome DB15x 15-pin D-sub with x pinout CC Conformal coating
remote display DB15HD High-density 15-pin D-sub #COMP Welded compression fittings
Secondary Instrument Types TFT Backlit color DNET DeviceNet DPORT Down port connections
3 Remote pressure sense port TFTRD Backlit color EIP Ethernet/IP EPDM EPDM elastomers
AS Low-range pressure sensor remote display I 6-pin locking DIN plus 8-pin mini-DIN FFKM FFKM/Calrez elastomers
B Battery-powered IO 6-pin locking DIN only IB Integrated barometer
C Flow or pressure controller ISC 4-pin locking DIN for external sensor IP# Ingress protection rating
D Dual valves MODBUS Modbus-RTU IPC Integrated potentiometer control
E Enclosed valve PROFIBUS Profibus DP-V1 NESSI NeSSI-compatible flow body
H Hammerhead valves RJ45 8-pin RJ45 #NPT non-standard NPT threads
P Large Pneutronics valve REMOTE Remote electronics assembly
Q High pressure gas flow SAE SAE threads
R High-flow Rolamite valve Valve Options SG Separate ground
S Stainless sensor for corrosives [no notation] Default valve (controllers) SILICONE Silicone elastomers
V Enclosed valve plus pneumatic BV Integrated bleed valve TMDPORT Top-mount down port
shutoff valve DS Downstream valve position #VCR Welded VCR fittings
W Whisper™ low pressure drop NO Normally open valve #VCO Welded VCO fittings
PAR Rolamite valve parallel wound coil VITON FKM/Viton elastomers
PCA# ASCO Numatics valve orifice size X CSA Class 1 Division 2/ATEX Zone 2
Stock Instrument Ranges
PCV# Small Pneutronics valve orifice size
2INH2OD Differential pressure range
RV Detached remote valve
2INH2OG Gauge pressure range
SV Small Pneutronics stainless valve
#CCM Liquid flow range (ccm)
#X# Rolamite valve hole pattern
EXTSEN External pressure sensor
#LPM Liquid flow range (lpm)
#PSIA Absolute pressure range (psi)
#PSID Differential pressure range (psi)
#PSIG Gauge pressure range (psi)
#SCCM Gas flow range (sccm)
#SLPM Gas flow range (slpm)
alicat.com

Adders usually present: Adder Codes


/CM, 102P, RIN, CIN, GAS: CH4, RANGE: 85 SCFH, TOT (99999.99 SCF), CLV, PU: V, BAUD: 38400, STP: 20°C, CPNT (5, 10), DS, 17025LF
Analog Signals
1x 1-5 Vdc
5x 0-5 Vdc B BAUD: # Baud rate
BD Bidirectional flow or gauge pressure calibration
PROFIBUS: # Profibus unit address
PU: x Selects flow parameter on power-up
10x 0-10 Vdc PUGS: x Gas selection on power-up
Cx 4-20 mA
x2x secondary signal
C CLP Closed-loop pressure control PUL: x Pulsed analog output at x flow total
CLV Closed-loop volumetric flow control PUSP: # Setpoint on power-up
CPNT (x,y,z) Additional calibration points PUT: # Tare after x seconds on power-up
xIN Setpoint input
xM Gas mass flow output
xP Pressure output
D DB: # Deadband % preset R RANGE: x Custom calibration range
DS Downstream valve placement RCPNT (x,y,z) Replacement calibration points
xT Temperature output RTL Right-to-left flow direction
xV Gas or liquid volumetric
flow output
G GAS: x Initial gas selection
S SENIN: x External pressure sensor input signal
RIN RS-232 input selection
H HC High-accuracy flow or pressure calibration SR: # Streaming rate in milliseconds
STP: x Custom STP conditions
I ID: # RS-232/485 unit address STR Preset to streaming mode

L LIQUID: x Custom liquid calibration T TOT Integrated flow totalizer


# 17025HF 17025 (L.A.B.) high-flow certification TOT (x y, R/F/E) Custom resolution x and/or units y
17025LF 17025 (L.A.B.) low-flow certification M MAXAVG Maximum geometric running averaging E Rolls over and flashes OVR error at max count
F Freezes and flashes OVR error at max count
A A2LA 17025 (A2LA) calibration certification N NTP: x Custom NTP conditions R Rolls over at max count
ALHx: y High flow alarm above y setpoint TOTAVG Totalizer averaging
ALLx: y Low flow alarm below y setpoint O OPL: x Overpressure limit for valve closure TOTBD# Bidirectional totalizers:
5 5 Vdc analog output OXC Oxygen cleaning TOTBD1 Negative values subtract from total
12 12 Vdc analog output TOTBD2 Negative values subtract from total, and
24 24 Vdc analog output P P1: x Expected inlet pressure total can never be negative
OD 500 mA open drain P2: x Expected outlet pressure TOTBD3 Negative values have no effect
APC Absolute pressure calibration for gas flow PD (p, d) Custom PD valve tuning TOTBD4 Negative values ignored, resets at zero
APHC High-accuracy absolute pressure calibration PD2I (p, d, i) Custom PD2I valve tuning
for gas flow POP Power over Profibus V VOL: x Expected closed volume