Features OMNI 6000 OMNI 6000E OMNI 7000: Data Sheet Omni Flow Computer Product Comparison
Features OMNI 6000 OMNI 6000E OMNI 7000: Data Sheet Omni Flow Computer Product Comparison
®
OMNI Flow Computer Product Comparison
1
Data Sheet
®
OMNI Flow Computer Product Comparison
ETHERNET CONNECTIVITY
Maximum Ethernet Ports 3 (3 SE Cards) 3 (3 SE Cards) 4 (2 DE Cards)
Maximum Ethernet Virtual Connections 24 24 32
Each virtual connection can have a separate
virtual Port number
No No
Ethernet Port Turnaround response time 100ms 100ms 6ms
RS-485 repeater ports can be used as RS-485
2-wire normal ports
No No
Ethernet Speed 10BaseT 10BaseT 10/100BaseT
Onboard Ethernet RJ-45 Connector Yes(100BaseT)
Automatic Ethernet RX/TX & Polarity Detection
Mix Modicon and Non-Modicon on same
physical Ethernet Port
Full Password Handling Over Ethernet
Software Selectable Termination on Ethernet
module RS-485 Ports
Secure Socket Layer (SSL) Connections
2
Data Sheet
®
OMNI Flow Computer Product Comparison
3
Data Sheet
®
OMNI Flow Computer Product Comparison
OMNICOM
OMNICOM OMNICONNECT
Enhanced
SOFTWARE
Modbus Database Browser
Custom User Defined Database Mappings (10)
Operate Menu - Real Time Data Screens
Operate Menu - OMNI Initialization Report
Diagnostics Menu - I/O Overview - Remote
Inputs Display
Diagnostics Menu - I/O Overview - Virtual
Inputs Display
Diagnostics Menu - Calibration
Diagnostics Menu - Checksums Display
Diagnostics Menu - Task Timings
Diagnostics Menu - Boolean/Variable
Statement Results
Diagnostics Menu - Reset Date/Time
Diagnostics Menu - Reset I/O Calibrations
Diagnostics Menu – Reset Prove Hist. Data
Diagnostics Menu - Reset Application Mode
Diagnostics Menu - Reset RAM
Diagnostics Menu - Reset Totalizers for Meters
and Stations
User Security Configuration Settings
Requests User Password to Gain Online Entry
SSL Connection Available
Software License Required
4
Data Sheet
®
OMNI Flow Computer Product Comparison
Descriptions for the Licensing Features in the OMNI 7000 STANDARD Firmware:
Gas & Liquid Combo Application
Offers a combination of gas and liquid meters used simultaneously. The user can select which meters are liquid and
which meters are gas. The liquid and gas meters are K-Factor curve application only. There are two stations that can be
configured: Station 1 is dedicated for the gas meters and Station 2 is for the liquid meters .
User Defined Database Mapping
Custom Database mapping is used when a client needs to access the OMNI using a different Modbus register set than
the native Modbus register addresses. It can also be used as a security measure to limit the registers available to a client
as read-only. There are 10 configurable maps available to the system. Each map contains a maximum of 1000
configurable points. The maps may be assigned to a serial or Ethernet port such that access via those ports are limited to
the points configured for the map.
Dual Stations
Only for all liquid applications or all gas applications, the user can have two stations in which to group meters. This may
be useful if two different station totals are required or customers are sharing an OMNI, each with their own meter set. For
the Combo applications, one station is automatically allocated for liquid and one station for gas.
SSL Security
Secure socket layer protocol or transport layer security – cryptographic protocols that provide communications security
over a computer network. The connection is private because the data is encrypted, the identity of the communicating
parties can be authenticated, and each message includes an authentication code to prevent undetected loss or alteration
of the data during transmission.
5
Data Sheet
®
OMNI Flow Computer Product Comparison
6
Data Sheet
®
OMNI Flow Computer Product Comparison
7
Data Sheet
®
OMNI Flow Computer Product Comparison
8
Data Sheet
®
OMNI Flow Computer Product Comparison
9
Data Sheet
®
OMNI Flow Computer Product Comparison
10
Data Sheet
®
OMNI Flow Computer Product Comparison
11
Data Sheet
®
OMNI Flow Computer Product Comparison
13
Data Sheet
®
OMNI Flow Computer Product Comparison
OMNI Flow Computers, Inc., pursuant to a policy of product development and improvement, may make any necessary changes to these specifications
without notice.
The OMNI Flow logo, “OMNI”, “OMNICOM”, “OMNICONNECT”, “OMNIPANEL”, and ”Measure the Difference”, are registered trademarks of OMNI Flow
Computers, Inc., in the United States and other countries. All other trademarks are the property of their respective owners.