0% found this document useful (0 votes)
108 views

Project:-Designed By: - Building: - Checked By: - Element: - Date: - Location

This document summarizes the design of 20 reinforced concrete columns for axial load only according to ACI318M-08. It provides the dimensions, reinforcement details, calculated concrete and steel capacities, total column capacities, and validation checks for 20 columns of various sizes. The columns vary in width from 300mm to 800mm, length from 400mm to 1000mm, and number of rebar from 6 to 26 bars. The document confirms all columns meet the ACI code requirements except for columns C14 and C15.

Uploaded by

MOHAMED AITAMEUR
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
108 views

Project:-Designed By: - Building: - Checked By: - Element: - Date: - Location

This document summarizes the design of 20 reinforced concrete columns for axial load only according to ACI318M-08. It provides the dimensions, reinforcement details, calculated concrete and steel capacities, total column capacities, and validation checks for 20 columns of various sizes. The columns vary in width from 300mm to 800mm, length from 400mm to 1000mm, and number of rebar from 6 to 26 bars. The document confirms all columns meet the ACI code requirements except for columns C14 and C15.

Uploaded by

MOHAMED AITAMEUR
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 9

Design of RC Column for Axial load only According ACI318M-08

Project :- College of Designed by:- M.A.S. Rev1.0


Building :- PART C Checked by:- M.A.S.
Element:- CLOUMNS Date:- 05-Apr-21
Location:- KSA

fc' = 30 N/mm2
fy = 420 N/mm2
Concrete Steel Ast RFT. Validation
Column width Length or No. of Rebar Stirrup Total
Φ Capacity Capacity of ACI 10.9
Mark mm Dia mm bars Dia. Type Capacity KN Ratio %
KN KN (1% - 8%)

C1 300 400 6 16 Normal 0.65 1575 263 1839 1.01% Ok Valid


C2 300 600 10 18 Normal 0.65 2353 557 2910 1.42% Ok Valid
C3 300 800 12 18 Normal 0.65 3142 668 3810 1.28% Ok Valid
C4 300 1000 14 20 Normal 0.65 3920 960 4880 1.47% Ok Valid
C5 400 400 14 20 Normal 0.65 2063 960 3023 2.75% Ok Valid
C6 400 800 18 22 Normal 0.65 4153 1494 5646 2.14% Ok Valid
C7 500 500 18 22 Normal 0.65 3224 1494 4718 2.74% Ok Valid
C8 600 600 20 22 Normal 0.65 4673 1660 6333 2.11% Ok Valid
C9 800 800 26 22 Normal 0.65 8355 2158 10513 1.54% Ok Valid
C10 D 400 8 16 Normal 0.65 1645 351 1996 1.28% Ok Valid
C11 D 400 8 16 Spiral 0.75 2017 431 2447 1.28% Ok Valid
C12 D 600 12 18 Normal 0.65 3709 668 4377 1.08% Ok Valid
C13 D 600 12 18 Spiral 0.75 4547 819 5366 1.08% Ok Valid
C14 D 1000 19 20 Normal 0.65 10335 1303 11638 0.76% Not Valid
C15 D 500 20 32 Normal 0.65 2390 3512 5902 8.19% Not Valid
C16 300 400 6 16 Normal 0.65 1575 263 1839 1.01% Ok Valid
C17 300 400 6 16 Normal 0.65 1575 263 1839 1.01% Ok Valid
C18 300 400 6 16 Normal 0.65 1575 263 1839 1.01% Ok Valid
C19 300 400 6 16 Normal 0.65 1575 263 1839 1.01% Ok Valid
C20 300 400 6 16 Normal 0.65 1575 263 1839 1.01% Ok Valid
C21 300 400 6 16 Normal 0.65 1575 263 1839 1.01% Ok Valid
C22 300 400 6 16 Normal 0.65 1575 263 1839 1.01% Ok Valid
C23 300 400 6 16 Normal 0.65 1575 263 1839 1.01% Ok Valid
C24 300 400 6 16 Normal 0.65 1575 263 1839 1.01% Ok Valid
C25 300 400 6 16 Normal 0.65 1575 263 1839 1.01% Ok Valid
C26 300 400 6 16 Normal 0.65 1575 263 1839 1.01% Ok Valid
C27 300 400 6 16 Normal 0.65 1575 263 1839 1.01% Ok Valid
C28 300 400 6 16 Normal 0.65 1575 263 1839 1.01% Ok Valid
C29 300 400 6 16 Normal 0.65 1575 263 1839 1.01% Ok Valid
C30 300 400 6 16 Normal 0.65 1575 263 1839 1.01% Ok Valid

Page 1 of 9
DIA (mm) Area (mm2)
6 29
8 51
10 79
12 114
14 154
16 201 Stirrup Type
18 255 Spiral
20 314 Normal
22 380
25 491
32 804
REV 02:
Select the Element Type( Beam or Slab) in cell F1 it will affect As min
As min For Beams & SLabs

REV 03:
in Torsion check, if the tension force is huge, the concrete
resistance will neglected according ACI 11.5.1.c _cell C73
REV 04:
changing Astirrup total equation in cell C84 to equal to 0.0 if there are no stirrups needed
new equation is =IF((Av+nst*At)>0,MAX(Av+nst*At,Avmin),0)
Blue color is new part in this equation

REV 05:
1- changing Cmax to Cc in εs' calculation in cell C49
2- Calculated Φcalculated in cell(J3) beside the sheet to allow user to modify the used on according ACI 9.3.2.1 & 10.3.4
3- in shear check, if the Nu is tension force, we will use Eq. 11-3 instead of 11-4 according ACI 11.2.1.2 _cell C57
4- Special Consideration for seismic Design
3.2.1 & 10.3.4