API 692 Seal Gas Filters & Separators
API 692 Seal Gas Filters & Separators
API 692
Seal Gas Filters
& Separators
1. Introduction
This document is intended to aid and guide in making filter other specific design parameters resulting in a significantly
and separator selections to be used for or part of a seal gas changed base design.
system in accordance with the first edition of the API 692 The requirements for transfer valves which are to be used
design standard as published in June 2018. It should serve as on all duplex components of a seal gas system have become
a useful reference guide for application and sales engineers more specific in API 692. As a standard all metallic parts
but is not a substitute for careful engineering analysis or must be made from stainless steel 316/316L as a minimum.
experience. This guide delivers the main changes between Also, the valves need to meet a leakage class as specified
the API 614 and API 692 design standard for (seal) gas filters in the ANSI/FCI 70-2. Other details influence the internal
and separators, the interpretation of those requirements design and material selection of the transfer valve which
and the standard requested deviations on the Indufil product between others is used in duplex gas filter arrangements.
line provided by John Crane.
API 614 Separation/ Although John Crane may recommend in its standard offering of
4 microns ß 85 = 98.8%
5th edition Buffer Gas filters and separators some deviations to the API 692, it should
API 692 Separation/ be emphasized that if a full compliance to the API 692 standard
10 microns ß 1,000 = 99.9%
1st edition Buffer Gas is preferred, this will be available as an option as well.
API 614
Seal Gas Filter 4 microns ß 85 = 98.8%
5th edition
API 692
Seal Gas Filter 1 micron ß 1,000 = 99.9%
1st edition
2
4. Key interpretations and Deviations
Seal Gas Filter
Most of the API 692 requirements are part of the standard gas coalescing filter is not limited by differential pressure
Indufil product design already and do not lead to an drop, but by the maximum gas velocity through the filter
alternative filter design. The new requirements result in element, in order to ensure a correct coalescence of liquids
finer filter elements with a higher filter efficiency tested in from the gas. Filter sizing based on three times normal flow
accordance with the ISO 12500 standard. The Indufil range of with a differential pressure limit of 10 kPa measured over the
filter elements include filter elements in compliance to the complete filter assembly can lead to significantly oversized
new requirements. gas filters based on a flow condition which in practice would
As a standard deviation to API 692, Indufil filters are sized at not occur.
three times normal flow calculated over the filter element not In case the deviation on filter sizing is not acceptable,
to exceed 10 kPa (0.10 bar) and at one time normal flow with then a sizing in full accordance to the API 692 is available,
a maximum drain layer gas velocity of 0.15 m/s, whichever but typically results in a larger filter system.
comes first. In practice, the maximum allowable flow for a (Continued on back)
API
API Text John Crane Considerations
Chapter
7.6.1 Filters for seal gas supply, secondary seal gas supply, and John Crane range of coalescing filter elements include
separation gas supply for contacting bushing-type seals are 99.9% efficient filters for 1 micron and larger particles.
coalescing and have a minimum efficiency of 99.9 % on particles
larger than or equal to 1 micron (Beta Ratio, ß 1 > 1,000).
7.6.2 Filters in separation seal gas supply and buffer gas supply to John Crane range of coalescing filter elements include
seals are coalescing and have a minimum efficiency of 99.9% 99.9% efficient filters for 10 microns and larger particles.
on particles larger than or equal to 10 microns (Beta Ratio,
ß 10>1,000)
7.6.5 Each filter is sized for a maximum clean pressure John Crane sizes the filter based on a maximum clean pressure drop
drop of 10 kPa (0.10 bar; 40 in. of water) at three times of 10 kPa at three times normal flow over the filter element. The filter
normal flow of all systems supplied. system clean pressure drop is calculated at one time normal flow
separately. Filter sizing is limited by the gas velocity measured at the
drain layer which might be reached before the pressure drop limitation.
Full compliance is available on request.
3
4. Key interpretations and Deviations (Continued)
North America Europe Latin America Middle East & Africa Asia Pacific
United States of America The Netherlands Brazil United Arab Emirates Singapore
Tel: 1-281-848-4469 Tel: 31-2631-90800 Tel: 55-11-3371-2500 Tel: 971-481-27800 Tel: 65-6518-1800
Fax: 1-281-293-9304 Fax: 31-2631-90808 Fax: 55-11-3371-2599 Fax: 971-488-62830 Fax: 65-6518-1803
If the products featured will be used in a potentially dangerous and/or hazardous process, your John Crane representative should be
consulted prior to their selection and use. In the interest of continuous development, John Crane companies reserve the right to alter
designs and specifications without prior notice. It is dangerous to smoke while handling products made of PTFE. Old and new PTFE
products must not be incinerated. ISO 9001 and ISO 14001 Certified, details available on request.