This document provides instructions for installing software and configuring a single HMI system. It involves pre-installing Windows and .NET frameworks, installing loopback and HMI software, configuring the HMI node and folders, and rebuilding the menu file.

Uploaded by

Kiên Nguyễn
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
185 views

Software Installation and HMI Configuration

This document provides instructions for installing software and configuring a single HMI system. It involves pre-installing Windows and .NET frameworks, installing loopback and HMI software, configuring the HMI node and folders, and rebuilding the menu file.

Uploaded by

Kiên Nguyễn
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

2.

Software installation
(Single HMI)

1/
GE Confidential
May 2007
Pre installation
• Windows XP SP2 or above
• Microsoft..net Framework 1.1 or above

dotnetfx2.exe

2/
GE Confidential
May 2007
Microsoft loopback adapter Installation

• Reason
Ms loopback adapter with WinXp is a useful tool for software learning and
commisioning. It is a virtual card. In software learning and
commisioning, we use a OC6000e network like:

•steps HMI MPC VDPU VDPU

1.Start_setting_control panel_add
hardware……
2.Set the virtual card
IP: 192.168.101.81
sub mask: 255.255.255.0

3/
GE Confidential
May 2007
HMI software installation
Steps:
1. Install the HMI software, then run MPC

4/
GE Confidential
May 2007
MPC interface

GPS

HMI
(HSU)

Controller Controller
(UCSA A) (UCSA B)

IO Net A
IO Net B

IO module IO module IO module IO module


(AI) (AO) (DI) (DO)

5/
GE Confidential
May 2007
HMI node configuration

Steps:
1. Set net A’s IP, etc
2. Save current setting. Close MPC and start
again.
6/
GE Confidential
May 2007
Main folder D:\OC_6000e

MPC.exe HMI software console


AlmAction.exe Alarm action
AlmHist.exe Alarm history
AlmList.exe Alarm list
Diagnostics.exe System diagnostics
EgdMonitor.exe Egd status monitor
FigEdit.exe Figure edit
FigView.exe Figure view
HistDataSrv.exe History data collect
HistReportCnfg.exe History report configuration
NTPDiag.exe NTP diagnostics
PrtRpt.exe Print history report
ReportSrv.exe History report collect
SoftKbd.exe Soft-keyboard
SystemCFG.exe System configuration
TagInfo.exe Query a point from global database
TagList.exe List the whole global database
Trend.exe Call a group of trend
VirtualCtrl.exe Virtual controller
7/
GE Confidential
May 2007
Data folder D:\OC_6000e\Data
Steps:
1. View folder \controller, backup files of DPU configuration, DPU**.txt
2. View folder \Fig, monitoring figure files of operator, ***.tig

8/
GE Confidential
May 2007
Replace Data folder
Steps:
1. Rename the installing data folder
2. Copy the project data folder to D:\OC6000e.
3. Close Figview and run again.

9/
GE Confidential
May 2007
Add training example files to current data
Steps:
1. Copy example\controller\*.txt to data\controller
2. Copy example\fig\*.tig to data\fig
3. Edit the file Data\fig\config\Hierarchy.xls
4. Start FigEdit, Rebuild Menu File
5. Close Figedit, FigView. Then restart Figview

10 /
GE Confidential
May 2007
Rebuild Menu File

11 /
GE Confidential
May 2007

You might also like