ROHS Test Report For Solar Street Light
ROHS Test Report For Solar Street Light
:
Client Company Shenzhen Alishine Energy Technology Co., Ltd
***********************************************************************************************************************************
***********************************************************************************************************************************
Test item:
(1)Cd,Pb,Hg
(2)Cr(VI)
(3)PBBs, PBDEs
Test standard :
(1) With reference to IEC 62321, Ed.1 111/95/CDV, EPA3050B:1996,EPA3052:1996 Analysis was
performed by ICP
(2) With reference to IEC 62321, Ed.1 111/95/CDV, EPA3060A:1996, EPA 7196A:1992,
ISO3613:2000(E), Analysis was performed by UV
(3) With reference to IEC 62321, Ed.1 111/95/CDV, EPA3540C:1996, Analysis was performed by
GC-MS
Conclusion: The delivery sample complied with ROHS directive
Date:2018-03-21
TEST REPORT
REPORT No.: CTB180314001C Date:2018-03-21 Page 3 of 8
SAMPLE COMPONENTS Item Results Results Chemical Conclusion
NO. of of testing (P/F)
EDXRF testing limit
(P/F/D) (mg/kg) (mg/kg)
1
The shell Cd P N.D. < 100 P
Cr P N.D. <1000 P
Hg P N.D. <1000 P
Pb P N.D. <1000 P
PBBs P N.D. <1000 P
PBDEs P N.D. <1000 P
2
Black plastic Cd P N.D. <100 P
Cr P N.D. <1000 P
Hg P N.D. <1000 P
Pb P N.D. <1000 P
PBBs P N.D. <1000 P
PBDEs P N.D. <1000 P
3
PCB Cd P N.D. <100 P
Cr P N.D. <1000 P
Hg P N.D. <1000 P
Pb P N.D. <1000 P
PBBs P N.D. <1000 P
PBDEs P N.D. <1000 P
4
Cable Cd P N.D. <100 P
Cr P N.D. <1000 P
Hg P N.D. <1000 P
Pb P N.D. <1000 P
PBBs P N.D. <1000 P
PBDEs P N.D. <1000 P
5
Lamp bead Cd P N.D. <100 P
Cr P N.D. <1000 P
Hg P N.D. <1000 P
Pb P N.D. <1000 P
PBBs P N.D. <1000 P
PBDEs P N.D. <1000 P
6
Transparent Cd P N.D. <100 P
Cr P N.D. <1000 P
plastic
Hg P N.D. <1000 P
Pb P N.D. <1000 P
PBBs P N.D. <1000 P
PBDEs P N.D. <1000 P
TEST REPORT
REPORT No.: CTB180314001C Date:2018-03-21 Page 4 of 8
Remark:
(1) It is the result on total Br while test PBBs and PBDEs by EDXRF. It is the result on total Cr while test Hexavalent
Chromium by EDXRF 。
(2) Results are obtained by EDXRF for primary screening, and chemical testing by ICP (for Cd, Pb, Hg),UV-VIS (Cr(VI)) and
GCMS (for PBBs, PBDEs) is recommended to be performed, if the
concentration exceeds the below warning value according to IEC 62321:2013 (unit:mg/kg)
Element Polymer
Cd P≤ σ < < P ≤ 70-3 σ < D <
70-3 D P≤ σ< <
50-3 D
σ≤
130+3 130+3σ≤F
F σ≤
150+3 F
Pb ≤ σ< <
P 700-3 P≤700-3σ<D<
D ≤ σ< <
P 500-3 D
σ≤
1300+3 1300+3σ≤F
F σ≤
1500+3 F
Hg ≤ σ< <
P 700-3 P≤700-3σ<D<
D ≤ σ< <
P 500-3 D
σ≤
1300+3 1300+3σ≤F
F σ≤
1500+3 F
Br ≤ σ<
P 300-3 ------
D ≤ σ<
P 250-3 D
Cr ≤ σ<
P 700-3 P≤700-3σ<D
D ≤ σ<
P 500-3 D
; ;
P = PASS F = FAIL D = DETECTED ;
;
(3) mg/kg = ppm N.D. = NOT DETECTED (< ) : : ;
MDL Pb, Cd, Hg 10 mg/kg; Cr(VI) 2mg/kg PBBs, PBDEs 5mg/kg :
(4) According to IEC 62321:2013, result on Cr(VI) for metal sample is shown as Positive/Negative. Positive = Presence of
Cr(VI) coating, Negative = Absence of Cr(VI) coating
TEST REPORT
REPORT No.: CTB180314001C Date:2018-03-21 Page 6 of 8
Photo documentation
TEST REPORT
REPORT No.: CTB180314001C Date:2018-03-21 Page 7 of 8
Photo documentation
TEST REPORT
REPORT No.: CTB180314001C Date:2018-03-21 Page 8 of 8
Photo documentation