This document provides information to check for overturning of a retaining wall, including unit weights of different materials, dimensions of the wall and soil, calculated pressures and moments. It then calculates the overturning moment and resisting moment to check that the factor of safety against overturning is greater than 1.4, indicating the wall design is safe.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100%(1)100% found this document useful (1 vote)
755 views
Check For Overturning
This document provides information to check for overturning of a retaining wall, including unit weights of different materials, dimensions of the wall and soil, calculated pressures and moments. It then calculates the overturning moment and resisting moment to check that the factor of safety against overturning is greater than 1.4, indicating the wall design is safe.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1
CHECK FOR OVERTURNING
Unit weight of soil, γsoil = 21 kN/m^3
Unit weight of Concrete = 25 kN/m^3 Unit weight of brick 19 kN/m^3 Unit weight of RR Masonry block = 22 kN/m^3 Surcharge load (ws) = 10 kN/m^2 Earth pressure coefficient,Ka = 0.33 Thickness of wall, step-1 (t) = 0.3 m Thickness of wall, step-2 (t) = 0.75 m Step-1, height = 1.9 m Step-2, height = 1.4 m Height of soil to be retained by RR Masonry block = 1.4 m Beam width = 0.3 m Beam depth = 0.38 m Height of soil filling = 0.38 m Soil Pressure at bottom of wall = (Ka*γsoil*h) 9.70 kN/m^2 (0.33x21x1.4) Soil Pressure at top of wall = (ws*Ka) 3.30 kN/m^2 (0.33x10) Soil Pressure at FGL beam bottom of wall = (Ka*γsoil*h) 2.64 kN/m^2 (0.33x21x(0.38))+(0.33*10) Factor of safety = 1.40
Total pressure on wall (Pa) = 0.5x(9.702+3.3+2.64)x1.4 13.26 kN/m/m length
13.26x1.4/3x(((9.702+3.3)+2x(2.64))/((9. Over turning Moment of wall (Mo) = 7.23 kN-m/m length 702+3.3)+2.64)) (0.3X1.9X19X0.15)+(0.75X22X1.4X0.3 Resisting Moment (Mr) = 11.52 kN-m/m length 75)+(0.3X0.38X25X0.15)
STABILITY CERTIFICATE FOR PATIL SADAN I Hereby Certify That I Had Inspected The Above Referred Structure With A View To Ascertain The Structural Stability of The Building
Download Complete (Ebook) Beginning gRPC with ASP.NET Core 6: Build Applications using ASP.NET Core Razor Pages, Angular, and Best Practices in .NET 6 by Anthony Giretti ISBN 9781484280072, 1484280075 PDF for All Chapters