0% found this document useful (0 votes)
143 views

Woltman Type Flow Meter

The document provides information about the DWM-A Turbine Water Meter. It can measure the volume of cold potable water passing through pipelines for industrial and municipal use. It features a hermetically sealed register, low head loss, a maximum working pressure of 16 bar, and easy maintenance. Sizing ranges from 2 to 20 inches, with maximum working temperatures of 60°C. Installation requires flushing the line and installing the meter in a straight section of pipe with sufficient upstream and downstream clearances.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
143 views

Woltman Type Flow Meter

The document provides information about the DWM-A Turbine Water Meter. It can measure the volume of cold potable water passing through pipelines for industrial and municipal use. It features a hermetically sealed register, low head loss, a maximum working pressure of 16 bar, and easy maintenance. Sizing ranges from 2 to 20 inches, with maximum working temperatures of 60°C. Installation requires flushing the line and installing the meter in a straight section of pipe with sufficient upstream and downstream clearances.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

update 03/09

DWM-A
DWM-A
Turbine Water Meter
Turbine
Applications
Water Meter
Woltman type water meter, used to measure the volume
of cold potable water passing through the pipeline.
Applications
For industrial/municipal use.
Woltman type water meter, used to measure the volume
of cold potable water passing through the pipeline.
Features use.
For industrial/municipal
Head Loss
• Meter will be installed in vertical, horizontal
Features
or inclined position 3.0
50 56 85 100 125 150 200 250 300 400

2.0
• Meter• will be installed
Hermetically in register
sealed vertical,(magnetic
horizontal or inclined
coupling)
500
position
• Low Head Loss 1.0
Head Loss (m)

0.7
• Hermetically
• Maximum sealed register
working (magnetic
pressure 16 bar coupling) 0.5
0.4
• Low •Head
EasyLoss
maintenance of the measuring unit
0.3
0.2
• Maximum working pressure 16 bar
• Dial Plate can be supplied in m3, or US gallons.
• Easy maintenance of and
Totalizer has big the clear
measuring
numeralsunit 0.1
10 20 30 40 50 70 100 200 300 400 600 1000 2000 3000 5000

• Dial Plate can be supplied in m3, or US gallons. 3


Flow Rate (m /h)
• Maximum working tempt. 60˚C
Totalizer has big and clear numerals
• Maximum working tempt. 60˚C
Options Accuracy Curve
Options
• Equiped with option for electrical output +5
• Equiped with
• Hot option
water forinelectrical
meters output
size 2” to 8” +2
• Hot water meters in size 2” to 8”
Error (%)

-2
Installation
Installation Requirements
Requirements
-5
• Prior• flushing of line
Prior flushing ofbefore water
line before meter
water meterinstallation
installation
• Meter• shall
Meterbe fullbeoffull
shall water at flow
of water measuring
at flow measuring (50% Qmax)
• Install Qmin Qt Qn Qmax
• meter in theinline
Install meter with
the line straight
with straightpipe 5xDNlength
pipe 5xDN length
Flow Rate (m3/h)
at up stream and 3xDN at down stream
at up stream and 3xDN at down stream

E V E R Y T H I N G I S U N D E R C O N T R O L
DWM-A
DWM-A
Turbine Water
Meter
Turbine Water Meter
Dimensions
inch 2” 2 1/2” 3” 4” 5” 6” 8” 10” 12” 16” 20”
Size DN
mm 50 65 80 100 125 150 200 250 300 400 500
L-Length mm 200 200 225 250 250 300 350 450 500 600 800
DN
H

H-Height mm 256 256 276 286 286 345 373 493 516 631 739

Weight kg 12 13 16 18 20 42 64 94 114 199 340

Performance data
inch 2” 2 1/2” 3” 4” 5” 6” 8” 10” 12” 16” 20”
Size DN
mm 50 65 80 100 125 150 200 250 300 400 500
Nominal Flow Rate
Dorot Qn (m3/h) (±2%)
Max. Flow Rate
15 25 40 60 100 150 250 400 600 1000 1500

Qmax (m3/h) (±2%) 30 50 80 120 250 300 500 800 1200 2000 3000
B 0 0 0 0 0 0 Transition Flow Rate
Qn 15m3/h m3 Qt (m3/h) (±2%) 3 5 8 12 20 30 50 80 120 200 300
DN 50mm 9 0 1 Min. Flow Rate
PN 16
8
7
2
3 Qmin (m3/h) (±5%) 0.65 0.7 1.2 1.8 3 4.5 7.5 12 18 30 45
6 5 4
DWM-A
Max. Register
X 0,1 Capacity (m3) 999999 999999 999999 999999 999999 999999 999999 999999 999999 999999 999999
I I I
I I I I I I I I I
I I Min. Reading Unit
9 0 1
I I I I
I I

(m3) 0.01 0.01 0.01 0.01 0.01 0.1 0.1 1 1 1 1


I I
I I I
I

I I
I I

I I
I I

8 2
I I
I I

I I I
I I I I I I I I

I I I I I I I I

7 3 X 0,01
I I I

I I
I I

6 5 4
I I
I I

I I
I I

I
I

I I I
I I I I
I I I I
I I I I I
I I II I I I I

How to Order
Model Optional Diameter Flange Standard *Outputs
Flow Sensor
DWM AF - Standard (with preparation
A small rotating “star” for Electrical Output) ISOISO
- ISO PN 16
PN16
in the center of the dial AN ANSI
- ANSI125
125
plate helps to detect AE - With Electrical Output 2” - 20” V - Volume (Electrical)
BS - BSTD
BSTD
even the smallest flow 50mm - 500mm F - Flow (Optical)
AH - Hot Water JI - JIS 10
JIS 10
through the meter. ABABNT
- ABNT PN16
PN16
AQ - Hot Water
with Electrical Output
* V - for Volume electrical out put (reed switch)
Example: Volumetric Electric output, 80mm, ANSI125 flange
* F - for Flow rate out put (optical)
DWM-AE-3-AN-V
DWM-A/7.2004

w w w. d o r o t . c o m • E - m a i l : i n f o _ d @ d o r o t . c o m
Dorot CONTROL VALVES Kibbutz Dorot, Mobile Post Hof Ashkelon 79175, Israel. Tel: 972-8-6808848, Fax: 972-8-6808751, www.dorot.com
DWM-A Turbine Water Meter
DWM-A Components
DWM-A Turbine Water Meter
Parts list

w w w. d o r o t . c o m • E - m a i l : i n f o _ d @ d o r o t . c o m

You might also like