A transmission line with an electrical length of 0.35λ is terminated with a load impedance of 60+j30 Ω. The reflection coefficient Γ is calculated to be 0.307e^j132.5, the standing wave ratio S is calculated to be 1.89, and the input impedance Zin is calculated to be 64.8-j38.3 Ω. These results are verified using circuit design software.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100%(1)100% found this document useful (1 vote)
197 views2 pages
Problem 2.28: Solution
A transmission line with an electrical length of 0.35λ is terminated with a load impedance of 60+j30 Ω. The reflection coefficient Γ is calculated to be 0.307e^j132.5, the standing wave ratio S is calculated to be 1.89, and the input impedance Zin is calculated to be 64.8-j38.3 Ω. These results are verified using circuit design software.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2
Problem 2.28 A lossless transmission line of electrical length l = 0.
35λ is terminated in a load impedance as shown in Fig. P2.28. Find Γ, S, and Zin . Verify your results using CD Modules 2.4 or 2.5. Include a printout of the screen’s output display.
l = 0.35λ
Zin Z0 = 100 Ω ZL = (60 + j30) Ω
Figure P2.28: Circuit for Problem 2.28.
Solution: From Eq. (2.59),
ZL − Z0 (60 + j30) − 100 ◦
Γ= = = 0.307e j132.5 . ZL + Z0 (60 + j30) + 100
From Eq. (2.73),
1 + |Γ| 1 + 0.307 S= = = 1.89. 1 − |Γ| 1 − 0.307 From Eq. (2.79) µ ¶ ZL + jZ0 tan β l Zin = Z0 Z0 + jZL tan β l " ¡ ¢# (60 + j30) + j100 tan 2πλrad 0.35λ = 100 ¡ ¢ = (64.8 − j38.3) Ω. 100 + j(60 + j30) tan 2πλrad 0.35λ