PERTEMUAN KE LIMA
TENTANG GAS PREHEATER
DODY GUNTAMA, ST., M.Eng
GAS PREHEATER
Stream containing 10% CH4 and 90% air by volume is to be
heated from 20 C to 300 C.
Calculate the required rate of heat input in kilowatts if the flow
rate of the gas is 2000 liters (STP)/min.
Substances a b c d
CH4(v) 0,03431 5,469x10-5 0,3661x10-8 -11x10-12
Air(v) 0,02894 0,000004147 3,191E-09 -1,965E-12
JAWABAN 300
5
5 , 469 x 10
8,93[(34,31x10 3 )(300 20) (300 2 20 2 )
2
0,3661x10 8 11 x10 12
(3003 203 ) (300 4 20 4 )]
3 4
5
0 , 4147 x10
80,37[(28,94 x10 3 )(300 20) (300 2 20 2 )
2
0,3191x10 8 1,965 x 10 12
(3003 203 ) (300 4 20 4 )]
3 4
Q 776 kJ/min 12,93 kJ/sec 12,93 kW
JAWABAN
DENGAN CARA 2
CEK CARA DI EXCEL
OUTPUT : INPUT :
SOAL TUGAS KERJAKAN MENGGUNAKAN EXCEL KIRIM JAWABAN DI EMAIL DAN FORUM
HASIL AKHIR SAJA
Stream containing 20% C2H4 and 80% air by volume is to be heated from 10 C to
260 C. Calculate the required rate of heat input in kilowatts if the flow rate of the
gas is 3000 liters (STP)/min.
Substances a b c d
C2H4(v) 0,04075 0,0001147 -6,891E-08 1,766E-11