Amendments To The Code of Practice For Structural Use of Steel 2011 Item Clause/ Annex Current Version Amendments Remarks

The document summarizes proposed amendments to the Code of Practice for Structural Use of Steel 2011. Several clauses and terms are amended for consistency, including replacing instances of "oscillation" and "vibration" with simply "vibration". Standards referenced are also updated, such as increasing the characteristic strength of reinforcement bars to 500N/mm2. Tables are revised with corrected values. Overall the amendments aim to improve consistency and accuracy in the code.

Uploaded by

shifuka
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
55 views

Amendments To The Code of Practice For Structural Use of Steel 2011 Item Clause/ Annex Current Version Amendments Remarks

The document summarizes proposed amendments to the Code of Practice for Structural Use of Steel 2011. Several clauses and terms are amended for consistency, including replacing instances of "oscillation" and "vibration" with simply "vibration". Standards referenced are also updated, such as increasing the characteristic strength of reinforcement bars to 500N/mm2. Tables are revised with corrected values. Overall the amendments aim to improve consistency and accuracy in the code.

Uploaded by

shifuka
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Amendments to the Code of Practice for Structural Use of Steel 2011

Item Clause/ Current Version Amendments Remarks


Annex
1 Clause The terms “oscillation” and “vibration” are
1.1 – para. collectively read as “vibration” for
9 consistency.

2 Clause
1.2.5 –
para. 3

3 Clause 2.2 The terms “Vibration” and “Wind induced


- Table 2.1 oscillation” stated in Table 2.1 are amended
to “Human induced vibration” and “Wind
induced vibration” respectively.

4 Clause The terms “oscillation” and “vibration” are


2.3.3 – collectively read as “vibration” for
para. 3 consistency.

5 Clause
2.4 – para.
1

Legends : revision/addition
1
6 Clause 5.2 The terms “oscillation” and “vibration” are
- Table 5.1 collectively read as “vibration” for
consistency hence the word “oscillation” is
deleted.

7 Clause 5.3

8 Clause The terms “oscillation” and “vibration” are


5.3.2 collectively read as “vibration” for
consistency.

9 Clause The terms “oscillation” and “vibration” are


5.3.3.1 collectively read as “vibration” for
consistency hence the word “oscillation” is
deleted.
10 Clause
5.3.5

11 Clause For second-order direct analysis,


6.8.3 – imperfections in both axes should be
equation considered for members in bending about
6.14 strong axis and sensitive to lateral torsional
buckling.

Legends : revision/addition
2
12 Clause Torsional restraint requirement of beams at
8.2 – the ends to prevent lateral torsional buckling
para.1 is revised from full restraint to nominal
restraint
13 Clause Typo error on designation of buckling curves
8.7.6 - for the grade of hot-finished structural hollow
Table 8.7 section less than or equal to S460 is rectified.

Legends : revision/addition
3
14 Clause Typo error on the upper bound of equation
9.3.6.1.6 – 9.23 in calculating the reduction factor β p is
equation rectified.
9.23

15 Clause The characteristic strength of reinforcement


10.1.3 bar is changed to 500N/mm2 to meet with the
latest reinforcement bar standard CS2:2012

16 Clause (a) The column “Nominal height” is


10.3.2.2 - deleted.
Table 10.7 (b) The minimum as-welded height of
25mm shank diameter shear stud is
amended.
(c) The corresponding characteristic
resistances of headed shear stud for
various concrete cube strengths are
revised.

Legends : revision/addition
4
17 Clause The design strength of reinforcement bar is
12.1 changed to 500N/mm2 to meet the latest
reinforcement bar standard CS2:2012

18 Clause A table extracted from BS EN 1992-1-2:2004


-
12.1.4 - showing the strength reduction factors for hot
Table rolled bars at elevated temperatures is added.
12.2e
(added)

19 Clause The terms “oscillation” and “vibration” are


13.2.5 collectively read as “vibration” for
consistency.

Legends : revision/addition
5
20 Clause The terms “oscillation” and “vibration” are
13.2.6 collectively read as “vibration” for
consistency.

Legends : revision/addition
6
21 Clause The terms “oscillation” and “vibration” are
13.2.8 collectively read as “vibration” for
consistency.

Legends : revision/addition
7
22 Clause The terms “oscillation” and “vibration” are
13.5.5 collectively read as “vibration” for
consistency.

23 Paragraph The terms “oscillation” and “vibration” are


13.6.4 collectively read as “vibration” for
consistency hence the word “oscillation” is
deleted.

24 Annex The Chinese standard GB/T 700-2006 is


A1.1.3 added in the Acceptable Standard List.

Legends : revision/addition
8