The 6 Main Components of A Refrigeration System: K.F.Bartlett LTD - Catering Equipment, Refrigeration & Air-Conditioning

The document discusses the six main components of a refrigeration system: thermostatic expansion valve, evaporator, capacity control system, compressor, condenser, and receiver. It also mentions that Bartlett offers refrigeration, air conditioning, and catering equipment in Cornwall and the UK.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
51 views4 pages

The 6 Main Components of A Refrigeration System: K.F.Bartlett LTD - Catering Equipment, Refrigeration & Air-Conditioning

The document discusses the six main components of a refrigeration system: thermostatic expansion valve, evaporator, capacity control system, compressor, condenser, and receiver. It also mentions that Bartlett offers refrigeration, air conditioning, and catering equipment in Cornwall and the UK.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 4

K.F.

Bartlett Ltd - Catering equipment, refrigeration & air-conditioning

Plymouth01752 360077 Redruth01209 218334 Paignton01803 526222 Exeter01392 203000


  
 Home
 Catering Equipment
 Refrigeration
 Air Conditioning
 Domestic Appliances
 Laundry
 Repairs & Maintenance
 Projects
 Blog
 Contact Us
  

 Home 
 Blog

The 6 Main Components of a


Refrigeration System

When we hear the word refrigeration, we usually think of it as a unit that makes our food cold and fresh.
Luckily, one of the greatest engineering accomplishments over the centuries has been the development
and evolution of refrigeration.

Refrigeration involves the removal of heat from spaces, objects or materials while maintaining their
temperature below the surrounding atmosphere. Refrigeration would not exist without these basic
components:

The 6 Main Components of a Refrigeration System

THERMOSTATIC EXPANSION VALVE (TXV)

Before the evaporator, this is located at the end of the liquid line. TXV is a device that controls the amount
of refrigerant that flows to the evaporator. There you will find the floodback that is essential to maximise
the productivity of the evaporator, while stopping the extra liquid refrigerant from going back to the
compressor.

This device also helps to separate the high pressure and the low pressure sides of an air conditioning
system. Through the system’s liquid line, high pressured liquid refrigerant enters the valve but with the
TVX’s presence, the amount of liquid refrigerant entering the evaporator will be abridged.

EVAPORATOR

The sole purpose of the evaporator is to remove the unwanted heat from the product through liquid
refrigerants. The liquid refrigerant must be at a low-pressure. This low-pressure can be determined by two
factors – one is the heat being absorbed from the product to the liquid refrigerant and the other is the
removal of low-pressure vapour by the compressor.

CAPACITY CONTROL SYSTEM

As its name might suggest, the capacity control system regulates the power and energy consumption,
although it can also manage dehumidification or decrease compressor cycling. The on/off cycling of the
compressor is the simplest form of capacity control.
COMPRESSOR

This draws low-temperature and low-pressure vapour from the evaporator through the suction line; the
vapour will automatically be compressed once diverted – there will also be a rise in the temperature if the
vapour is compressed. In simple terms, a compressor can convert low-temperatures to high-
temperatures, which can be the cause of an increase in pressure. Through a compressor, heat can be
easily released.

CONDENSER

This device can extract heat from the refrigerant. Fans placed above the condenser unit draw air over the
condenser coils. The temperature of condensation should range from around -12°C to -1°C; vapour will
be cooled until it becomes a liquid refrigerant again, whereby it will retain some heat.

RECEIVER

As a temporary storage and a surge tank for liquid refrigerant, the receiver acts as a vapour seal. With a
primary purpose of preserving the vapour moving down the liquid line to the expansion valve, receivers
can be made for both horizontal and vertical installation.

Bartlett offers high quality refrigeration equipment in Cornwall and the rest of the UK. We also supply air
conditioning and catering equipment. For enquiries, you may email us at [email protected].

FacebookTwitterGoogle+Share
AuthorBartlettPosted onApril 13, 2016

Post navigation
PREVIOUS Previous post:5 Facts about Air Conditioning in the United Kingdom

NEXTNext post:Energy Saving Tips for Refrigeration Equipment

Search for:SEARCH

RECENT POSTS

 Fish and Chip Friday: Where it all Began


 Just One Cornetto
 Dinnerladies
 EastEnders: The Launderette
 Levi’s 501: The Launderette
SHARE THIS POST:

FacebookTwitterGoogle+Share
 

Payments accepted via: American Express, Visa, Visa Electron, Maestro,


Mastercard, JCB, Worldpay, PayPal

Our accociates: cedabond, Refcom, Gas safe, retra

© 2019 K.F.Bartlett Ltd - Catering equipment, refrigeration & air-conditioning

 Repairs & Maintenance


 Laundry|
 Domestic Appliances|
 Air Conditioning|
 Refrigeration|
 Catering Equipment|
 Home|
 Contact Us
 Sitemap|
 Terms & Conditions|
 Privacy|
 Support|
 Services|
 Brands|
 Latest Projects|
 Blog|
 About Us|
Website Design & Technology by Createanet

You might also like