This document contains instructions for two assignments on transformer connections and calculations. The first assignment involves calculating currents and power for a V-connected transformer supplying a star-connected load. It asks the student to draw phasor diagrams for the primary and secondary currents for both a V-connected and delta-delta connected transformer. The second assignment involves calculating line currents for a Scott-connected transformer supplying two single-phase loads from a three-phase supply. It asks the student to draw a phasor diagram showing the primary currents.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
56 views

Assignment-2 - SC 2

This document contains instructions for two assignments on transformer connections and calculations. The first assignment involves calculating currents and power for a V-connected transformer supplying a star-connected load. It asks the student to draw phasor diagrams for the primary and secondary currents for both a V-connected and delta-delta connected transformer. The second assignment involves calculating line currents for a Scott-connected transformer supplying two single-phase loads from a three-phase supply. It asks the student to draw a phasor diagram showing the primary currents.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Assignment

Submission Due on: 14.04.2021

1. Consider a V-connected (open delta) 3 phase transformer with the following details:
6600 V (Line-Line), 50 Hz three phase supply with A-B-C phase sequence. Star
connected 415 V (line-Line) load with (8+j6) Ω/phase of load impedance. The
transformer impedance may be neglected.
Take supply voltage phasor 𝑉 ̅̅̅̅̅
𝐴𝐵 as reference. (i) Calculate the phase (coil) current
phasors of primary and secondary winding and show them in a phasor diagram. (ii)
What is the power delivered to the load under this condition? (iii) Calculate the phase
(coil) current phasors of primary and secondary winding if it were a delta-delta
connected transformer and place them in the same phasor diagram as in (i).
Marks: 4+2+4=10

2. A Scott connected transformer is used to convert a 415 V (Line-Line), 3 phase, 50 Hz


supply to two 120 V (RMS), 50 Hz single phase supplies –SPI and SPII. The phasor
of SPI voltage leads the phasor of SPII voltage by 900. The load on SPI is 400 kW at
0.8 p.f. (lagging) and the load on SPII is 900 kW at unity p.f. Calculate the line
currents on the 3-phase side and draw the corresponding phasor diagram taking
supply voltage 𝑉̅̅̅̅̅
𝐴𝐵 as reference. Consider A-B-C phase sequence.
Marks: 6+4=10