DIESEL GENERATOR SET

STANDBY
600 ekW 750 kVA
50 Hz 1500 rpm 400 Volts
Caterpillar is leading the power generation
marketplace with Power Solutions engineered
to deliver unmatched flexibility, expandability,
reliability, and cost-effectiveness.
Image shown may not
reflect actual package.

FEATURES
EMISSIONS / FUEL STRATEGY CAT® 3412C TA DIESEL ENGINE
• Low BSFC
• Reliable, rugged, durable design
FULL RANGE OF ATTACHMENTS • Field-proven in thousands of applications
• Wide range of bolt-on system expansion worldwide
attachments, factory designed and tested • Four-stroke-cycle diesel engine combines
consistent performance and excellent fuel
ENCLOSURES (optional) economy with minimum weight
• Weather protective and sound attenuated
CAT SR4B GENERATOR
SINGLE-SOURCE SUPPLIER • Matched to the performance and output
• Fully prototype tested with certified torsional characteristics of Caterpillar engines
vibration analysis available • Optimum winding pitch for minimum total
harmonic distortion and maximum efficiency
WORLDWIDE PRODUCT SUPPORT
• Segregated low voltage, AC/DC accessory box
• Caterpillar® dealers provide extensive post sale
provides single point access to accessory
support including maintenance and repair
connections
agreements
• UL 1446 Recognized Class H insulation
• Caterpillar dealers fill 99.7% of parts orders within
24 hours
CAT CONTROL PANELS
• Caterpillar dealers have over 1,798 dealer branch
stores operating in 200 countries • Four levels of controls to meet individual
• The Cat® S•O•SSM program cost effectively detects customer needs:
internal engine component condition, even the - EMCP II offers digital monitoring, metering, and
presence of unwanted fluids and combustion protection
by-products - EMCP II+ offers EMCP II features plus
full-featured power metering and protective
relaying
- EMCP II+ Auto-Paralleling offers EMCP II+
features plus synchronization and load sharing
- Switchgear conversion offers easy interface for
remote switchgear
• UL 508A Listed
®

STANDBY 600 ekW 750 kVA


50 Hz 1500 rpm 400 Volts

FACTORY INSTALLED STANDARD & OPTIONAL EQUIPMENT

System Standard Optional


Air Inlet •Single element canister type air cleaner •Dual element air cleaner
•Service indicator •Heavy-duty air cleaner
Cooling • Radiator with guard and duct flange • Jacket water heater with shutoff valves
• Coolant drain line with valve • Heat exchanger and expansion tank
• Fan and belt guards
• Caterpillar® Extended Life Coolant
• Low coolant level alarm or shutdown
Exhaust • Stainless steel exhaust flex and ANSI outlet flange • Mufflers (20, 25, or 30 dBA)
• Elbow kit and through-wall installation kit
• Manifold and turbocharger guards
Fuel • Primary and secondary fuel filters • Manual transfer pump
• Water separator • Choice of three Automatic Transfer Systems
• Fuel priming pump • Low fuel level alarm
• Flexible fuel lines
• Fuel pressure gauge
Generator • Permanent magnet excited • Self excited
• Class H insulation • Digital Voltage Regulator
• Class F temperature rise (105°C prime/130°C standby) • Digital Voltage Regulator with KVAR/PF control
• VR6 Voltage Regulator, 3-phase sensing, 2:1 Volts/Hz • Anti-condensation space heater
• Reactive droop • Oversize and premium generators (648 ekW
• Extension box Prime/720 ekW Standby)
• Bus bar connection • Circuit breakers, UL Listed, 3-pole with shunt trip
• Circuit breakers, IEC Compliant, 3-pole or 4-pole with
shunt trip
• Multiple breaker capability
Generator • Permanent magnet excited • Self excited
• Class H insulation • Digital Voltage Regulator
• Class F temperature rise (105°C prime/130°C standby) • Digital Voltage Regulator with KVAR/PF control
• VR6 Voltage Regulator, 3-phase sensing, 2:1 Volts/Hz • Anti-condensation space heater
• Reactive droop • Oversize and premium generators (648 ekW
• Extension box Prime/720 ekW Standby)
• Bus bar connection • Circuit breakers, UL Listed, 3-pole with shunt trip
• Circuit breakers, IEC Compliant, 3-pole or 4-pole with
shunt trip
• Multiple breaker capability
Governor • PEEC - Cat Electronic • Electronic isochronous
• Electronic load sharing
Control Panels • EMCP II • EMCP II+
• Voltage adjustment potentiometer • Switchgear conversion
• Auto start/stop control switch • Customer Communication Module
• Emergency stop pushbutton • Local alarm and remote annunciator modules
• Panel lights
• Digital AC meter - 3 phase True RMS
• Digital Indicators
• Safety Shutdown protection with LED Lights
Lube • Lubricating oil and filter • Manual sump pump
• Oil drain line with valves
• Fumes disposal
Mounting • Formed steel base • Integral fuel tank base
• Linear vibration isolators between base and • Sub base fuel tank
engine-generator • Wide base
• Skid base
Starting/Charging • 45 amp charging alternator • Heavy-duty starting system
• Energized to run (ETR) fuel shutoff solenoid • 5 or 10 amp battery charger
• 24 volt starting motor • Oversize batteries
• Batteries with rack and cables • Ether starting aid
• Battery disconnect switch
General • Enclosures - sound attenuated, weather protective
• Automatic transfer switches (ATS)
• Floor standing circuit breakers
• CSA Certification
Note Standard and optional equipment may vary for UL
2200 Listed packages. UL 2200 Listed packages may
have oversized generators with a different
temperature rise and motor starting characteristics.
2 24 March 2006 4:01 PM
®

STANDBY 600 ekW 750 kVA


50 Hz 1500 rpm 400 Volts

SPECIFICATIONS

CAT SR4B GENERATOR CAT CONTROL PANELS

• EMCP II
Frame Size.........................................................................596
• 24 Volt CD Control
Excitation................................................ Permanent Magnet
• NEMA 1, IP22 enclosure
Pitch.............................................................................. 0.8667
• Electronically dead front
Number of poles...................................................................4
• Lockable hinged door
Number of bearings...................................... Single Bearing
• Generator instruments meet ANSI C-39-1
Insulation....................... UL 1446 Recognized Class H with
• Generator terminal box mounted
tropicalization and antiabrasion
IP Rating.........................................................Drip Proof IP22 • Single location customer connection point
Alignment.............................................................. Pilot Shaft • UL508A Listed
Overspeed capability - % of rated................................... 180 • Panel illuminating lights
Wave form....................................... Less than 5% deviation • Auto start/stop control
Paralleling kit/Droop transformer.......................... Standard • Voltage adjust potentiometer
Voltage regulator.3 Phase sensing with selectible volts/Hz • True RMS AC metering
Voltage regulation............Less than +/- 1/2% (steady state) • Digital indications for:
Less than +/- 1% (no load to full load) - RPM
Telephone Influence Factor.............................. Less than 50 - Operating hours
Harmonic distortion......................................... Less than 5% - Oil pressure
CAT DIESEL ENGINE - Coolant Temperature
- System DC volts
- AC volts, phase amps, Hz
3412C TA V-12, 4-stroke-cycle watercooled diesel • Shutdowns with indicating lights for:
Bore - mm................................................ 137.20 mm (5.4 in) - Low oil pressure
Stroke - mm............................................. 152.40 mm (6.0 in) - High coolant temperature
Displacement - L................................... 27.02 L (1648.86 in3) - Overspeed
Compression Ratio....................................................... 13.0:1 - Emergency Stop
Aspiration........................................................................... TA - Failure to start (overcrank)
Fuel system..................................................Pump and Lines
Governor type..................................... PEEC - Cat Electronic

3 24 March 2006 4:01 PM


®

STANDBY 600 ekW 750 kVA


50 Hz 1500 rpm 400 Volts

TECHNICAL DATA

Open Generator Set - - 1500 rpm/50 Hz/400 Volts DM0629


Package Performance
Genset Power rating @ 0.8 pf 750 kVA
Genset Power rating with fan 600 ekW
Fuel Consumption
100% load with fan 158.9 L/hr
75% load with fan 121.6 L/hr
50% load with fan 85.3 L/hr
Cooling System1
Ambient air temperature 57 ° C
Air flow restriction (system) 0.12 kPa
Air flow (max @ rated speed for radiator arrangement) 1236 m³/min
Engine coolant capacity 59.0 L
Exhaust System
Combustion air inlet flow rate 45.6 m³/min
Exhaust stack gas temperature 536.0 ° C
Exhaust gas flow rate 129.8 m³/min
Exhaust flange size (internal diameter) 203.2 mm
Exhaust system backpressure (maximum allowable) 6.7 kPa
Heat rejection
Heat rejection to coolant (total) 359 kW
Heat rejection to exhaust (total) 591 kW
Heat rejection to atmosphere from engine 96 kW
Heat rejection to atmosphere from generator 28.9 kW
Alternator2
Motor starting capability @ 30% voltage dip 1732 skVA
Frame 596
Temperature Rise 130 ° C
Lube System
Sump refill with filter 139.0 L
Emissions3
NOx mg/nm3 2947.9 mg/nm³
CO mg/nm3 170.2 mg/nm³
HC mg/nm3 109.5 mg/nm³
PM mg/nm3 45.1 mg/nm³
1
Ambient capability at 200 m (660 ft) above sea level. For ambient capability at other altitudes, consult your Caterpillar dealer.
2
Footnotes: 1. UL 2200 Listed packages may have oversized generators with a different temperature rise and motor starting
characteristics. Generator temperature rise is based on a 40 degree C ambient per NEMA MG1-32.
3
Emissions data measurement is consistent with those described in EPA CFR40 Part 89, Subpart D and ISO8178-1 for measuring HC, CO,
PM, NOx. Data shown is based on steady state operating conditions of 77° F, 28.42 in HG and number 2 diesel fuel with 35° API and LHV
of 18,390 btu/lb.

4 24 March 2006 4:01 PM


®

STANDBY 600 ekW 750 kVA


50 Hz 1500 rpm 400 Volts

RATING DEFINITIONS AND CONDITIONS

Meets or Exceeds International Specifications: ABGSM Ratings are based on SAE J1995 standard conditions.
TM3, AS1359, AS2789, BS4999, BS5000, BS5514, These ratings also apply at ISO3046/1, DIN6271, and
DIN6271, DIN6280, EGSA101P, IEC34/1, ISO3046/1, BS5514 standard conditions.
ISO8528, JEM1359, NEMA MG 1-22, VDE0530, Fuel Rates are based on fuel oil of 35º API (16º C or 60º F)
89/392/EEC, 89/336/EEC gravity having an LHV of 42 780 kJ/kg (18,390 Btu/lb)
Standby - Output available with varying load for the when used at 29º C (85º F) and weighing 838.9 g/liter
duration of the interruption of the normal source power. (7.001 lbs/U.S. gal).
Standby power in accordance with ISO8528. Fuel stop Additional Ratings may be available for specific
power in accordance with ISO3046/1, AS2789, DIN6271, customer requirements. Consult your Caterpillar
and BS5514. Standby ambients shown indicate ambient representative for details.
temperature at 100 percent load which results in a
coolant top tank temperature just below the shutdown
temperature.

5 24 March 2006 4:01 PM


®

STANDBY 600 ekW 750 kVA


50 Hz 1500 rpm 400 Volts

DIMENSIONS

Package Dimensions
Note: Do not use for installation design.
Length 4523.9 mm See general dimension drawings for
Width 1827.4 mm detail (Drawing #1863619).
Height 1960.4 mm
Weight 6700 kg

www.CAT-ElectricPower.com
© 2006 Caterpillar
All rights reserved.
Performance No.: DM0629
Materials and specifications are subject to change without notice.
Feature Code:: 412DE7H The International System of Units (SI) is used in this publication.
CAT, CATERPILLAR, their respective logos and "Caterpillar Yellow," as
Source:: U.S. Sourced well as corporate and product identity used herein, are trademarks of
Caterpillar and may not be used without permission.
24 March 2006 6287420
6