The MC2 electronic controller is found on ABAC Genesis machines. To access the service level of the MC2 controller, press enter twice to get to the password menu, then hold down the minus, up, and reset buttons while pressing enter twice. This will provide 5 minutes of service level access to see and change additional menus to assist with technical issues involving rotary screws.

Uploaded by

Philip Shaver
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
1K views1 page

ALUP ABAC MC2 Service Access

The MC2 electronic controller is found on ABAC Genesis machines. To access the service level of the MC2 controller, press enter twice to get to the password menu, then hold down the minus, up, and reset buttons while pressing enter twice. This will provide 5 minutes of service level access to see and change additional menus to assist with technical issues involving rotary screws.

Uploaded by

Philip Shaver
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

MC2 electronic controller

Found on ABAC Genesis machines

For SERVICE LEVEL access in the controller, press ENTER (P7) twice and
scroll down (P3) to PASSWORD, press ENTER (P7) once. Now hold down
the MINUS (P8), UP (P2) and RESET (P6) all at the same time, then press
ENTER (P7) twice. You will now have SERVICE LEVEL ACCESS to the
MC2 for 5 minutes and this will enable you to see and change more menus
than in the standard user access mode.