CONSORTIUM
6 LV
FT FT 0006A
7 12" 0007
0008 10m ground
7.1m
elevation change
8
8"
9 GRADE
LV
10 103 P-103A/B 0006B
P = 0 .06barg
11
12 2.8m
143-T-102
13
14 13.5m
15 EL = +40m
16
17 Pump Duty
18
19 Flowrate Min 142.2 m3/hr
20 Norm 237.0 m3/hr
21 Rated 260.7 m3/hr
22 Density Norm 842 kg/m3
23 Max 842 kg/m3
24 Vapour Pressure @ 70 C
o
3.5 bara
25
26
27
28 Suction Conditions
29
30 Suction Vessel Pressure 2.50 barg
31 Suction Vessel Elevation 6.5 m
32 LSLL above base or Tan line 300 mm
33 Elevation of Pump Centreline 0.7 m ( or suction impeller for Vertical Centrifugal Pump )
34 Suction Line Pressure Drop 0.086 bar
35 Suction Pressure 2.92 barg
36 Vapour Pressure 3.5 bara
37 Density of Fluid 842 kg/m3
38 Calculated NPSH 5.22 m
39 Margin 1.0 m
40 Available NPSH 4.2 m