0% found this document useful (0 votes)
91 views

Luminous Factors Energy Factors: Acoustic Simulated Values

This document provides technical specifications for a glazing unit consisting of two 8 mm thick panes of Planiclear glass laminated with a 0.38 mm thick PVB interlayer. The glazing unit has a total thickness of 16.38 mm and transmits 71% of light while reflecting 7% of light both outdoors and indoors. It has a thermal transmission of 5.3 W/(m2.K) and provides a sound reduction of 39 dB. The glazing also has burglar resistance of NPD and blocks 97% of UV light.

Uploaded by

Bassaouma Archi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
91 views

Luminous Factors Energy Factors: Acoustic Simulated Values

This document provides technical specifications for a glazing unit consisting of two 8 mm thick panes of Planiclear glass laminated with a 0.38 mm thick PVB interlayer. The glazing unit has a total thickness of 16.38 mm and transmits 71% of light while reflecting 7% of light both outdoors and indoors. It has a thermal transmission of 5.3 W/(m2.K) and provides a sound reduction of 39 dB. The glazing also has burglar resistance of NPD and blocks 97% of UV light.

Uploaded by

Bassaouma Archi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Saturday, April 24, 2021

Glazing 1 PLANICLEAR 8 mm

PVB PVB STANDARD 0.38 mm

Glazing 1' PLANICLEAR 8 mm

88.1

Name: ibtissam berkane


Notes: feuilleté
Country: Other

LUMINOUS FACTORS EN410 (2011-04) ENERGY FACTORS EN410 (2011-04)

Light Transmittance (TL) 87 % Transmittance (TE) 71 %


Outdoor Reflectance (RLe) 8% Outdoor Reflectance (Ree) 7 %
Indoor Reflectance (RLi) 8% Indoor Reflectance (Rei) 7%

THERMAL TRANSMISSION EN673-2011 Absorptance A1 (AE1) 22 %

SOLAR FACTORS EN410 (2011-04)


Ug 5.3 W/(m².K)
Angle relative to the vertical 0º Solar Factor (g) 0.76

MANUFACTURING SIZES Shading Coefficient (SC) 0.88

Nominal Thickness 16.38 mm COLOR RENDERING

Weight 40.4 kg/m² Transmission (Ra) 97

ACOUSTICS EN 12758 Reflection (Ra) 97

ANTI-BURGLARY EN 356
Acoustic simulated values
Rw (C;Ctr) 39 (-1; -3) dB Burglar Resistance NPD
STC (ASTM E413) 39
OITC (ASTM E1332) 35

UV FACTORS EN410 (2011-04)

TUV 3%

SAFETY CLASS EN 12600

Pendulum Body Resistance 2B2

Calumen calculates the photometric characteristics and thermal transmission of glass using calculation algorithms which comply with the following standards: the
European standards EN 410 and EN 673, the international standard ISO9050, the Japanese standard JIS R 3106/3107 and the Korean standard KS L 2514/2525.
The functional output and calculation rules of Calumen for standards EN 410 and EN 673 have been validated by TÜV Rheinland (report 11923R-11-33705). The
technical performances obtained according to these standards are provided for information only and are subject to amendment. Only the values entered in the
performance declaration available on the CE marking site of Saint-Gobain Glass are official. The sound attenuation indices are measured under laboratory conditions
according to the standards EN ISO 10140 and EN 12758. The calculated indices are provided for information only. The accuracy for Rw index lies within a range of
+/-2dB.The glass thickness calculations comply with the 2012 version of the DTU39-P4 description. The USER is responsible for ensuring that the correct calculation
hypotheses are entered and the DTU39 is applied appropriately for the project concerned.

You might also like