Draeger Safety

Draeger HazMat Simultest Kit


l This visual presentation is
intended to help the user
understand use of the
Draeger HazMat Simultest
Kit.
l Pictures may not represent
suitable respiratory
equipment and protective
clothing for every
situation. Proper
protection level should
always be determined by
the specifics of an event.

DSI Training ©2001


June 30, 2001 Page 1 HazMat Simultest Kit
Draeger Safety
D

Intended Use
l The Draeger HazMat
Simultest Kit is
designed to provide a
rapid identification
and quantification of
an unknown chemical
substance via the use
of specially designed
and calibrated
detector tube sets

DSI Training ©2001


June 30, 2001 Page 2 HazMat Simultest Kit
Draeger Safety
D

Intended Use
l Primary users of the
HazMat Simultest would
include:
w HazMat Squads
w Fire Service
w Industrial Emergency
Response Teams
w Confined Space Entry
Personnel
w Post Fire
Investigators
DSI Training ©2001
June 30, 2001 Page 3 HazMat Simultest Kit
Draeger Safety
D

Components of HazMat Simultest


l accuro® Bellows Pump
l 10 Simultest Tube Sets
l Simultest Set Adapter w/
Extension Hose
l Simultest Set and Deluxe
Tube Openers
l Laminated Instruction Cards
l Air Current Kit
l Pelican® Case/Custom Foam
l Space for additional boxes of
chemical specific Draeger-
Tubes is provided

DSI Training ©2001


June 30, 2001 Page 4 HazMat Simultest Kit
Draeger Safety
D

accuro® Pump
l The Draeger accuro®
pump is the standard unit
used for sampling with
Draeger-Tubes.
l It is used to draw a
calibrated 100 cc of air
through the Simultaneous
Test Sets on each pump
stroke
l Bellows design allows for
easy one-hand operation

DSI Training ©2001


June 30, 2001 Page 5 HazMat Simultest Kit
Draeger Safety
D

The Simultaneous Test Sets


l The HazMat Simultest Kit contains 3
separate semi-quantitative Simultest Sets
l Each set consists of 5 different specially
designed and calibrated detector tubes
l Sampling procedures and ambient
condition criteria are the same for all 3
test sets
w This system allows for a very rapid
screening of 15 chemicals or chemical
families when testing for unknowns
DSI Training ©2001
June 30, 2001 Page 6 HazMat Simultest Kit
Draeger Safety
D

HazMat Simultest Set I


l Simultaneous Test Set I detects the following:
¬ Acid Gases (Hydrochloric Acid, Nitric Acid, etc.)
- Hydrocyanic Acid
® Carbon Monoxide
¯ Basic Gases (Ammonia, Butylamine, etc.)
° Nitrous Gases (NO + NO2)
l 3 of Set I are provided in the HMS Kit

w Additional detail on chemicals detected with these tubes is


provided in the “Instructions for Use”

DSI Training ©2001


June 30, 2001 Page 7 HazMat Simultest Kit
Draeger Safety
D

HazMat Simultest Set II


l Simultaneous Test Set II detects the following:
¬ Sulfur Dioxide
- Chlorine
® Hydrogen Sulfide
¯ Carbon Dioxide
° Phosgene
l 3 of Set II are provided
in the HMS Kit

w Additional detail on chemicals detected with these


tubes is provided in the “Instructions for Use”

DSI Training ©2001


June 30, 2001 Page 8 HazMat Simultest Kit
Draeger Safety
D

HazMat Simultest Set III


l Organic compounds are all grouped in this set
l Simultaneous Test Set III detects the following:
¬ Ketones (Acetone, Methyl Ethyl Ketone, etc.)
- Aromatics (Benzene, Toluene, etc.)
® Alcohols (Methanol, Ethanol, etc.)
¯ Aliphatic Hydrocarbons
(Hexane, Octane, etc.)
° Chlorinated Hydrocarbons
(Perchloroethylene, TCE, etc.)
l 4 of Set III are provided
in the HMS Kit
w Additional detail on chemicals detected with these tubes is
provided in the “Instructions for Use”
DSI Training ©2001
June 30, 2001 Page 9 HazMat Simultest Kit
Draeger Safety
D

Simultest Set Adapter and Hose


l A special adapter is
used to connect the
Simultest Sets to the
accuro® bellows
pump
l This adapter consists
of a 5 slot manifold for
the tube sets, 1 meter
extension hose and
quick connect to
pump

DSI Training ©2001


June 30, 2001 Page 10 HazMat Simultest Kit
Draeger Safety
D

Using the Kit


l To determine what
substance(s) are
present, all three
Simultest Sets should
be used
l The order in which the
tests are taken does not
matter
l However, Draeger
recommends that the
tests be taken in the
order of I, II then III for
consistency in use
DSI Training ©2001
June 30, 2001 Page 11 HazMat Simultest Kit
Draeger Safety
D

Opening the Simultest Sets


l Scrape ceramic edge of the Flow Indication Arrow

Simultest Set Opener at


multiple times to score the
glass tips
l Push opener completely over
rubber block with ceramic
cutter up and apply pressure Ceramic cutter “up”
down until all tube tip break off
l Insert the tube set into the
adapter (flow arrow pointing in)
and then break tips on other
side of set
DSI Training ©2001
June 30, 2001 Page 12 HazMat Simultest Kit
Draeger Safety
D

Assembling the System


l Assemble the Tube
Set, Extension Hose
and accuro Pump as
shown

DSI Training ©2001


June 30, 2001 Page 13 HazMat Simultest Kit
Draeger Safety
D

Operation of the accuro® Pump


l Grip the pump as
shown
l Squeeze the pump until
it will no longer
compress (the stroke
indicator will have
advanced)
l Allow the bellows to re-
expand by itself until
reappearance of the
white dot on top
indicates end of stroke
DSI Training ©2001
June 30, 2001 Page 14 HazMat Simultest Kit
Draeger Safety
D

Operation of the Kit


l When in the area of
the suspected
contamination...
l Take 10 complete
pump strokes
w Each stroke will take
from 2 to 6 seconds
l Evaluate any color
change in the tested
tube set immediately
upon completion of
the 10 pump strokes
DSI Training ©2001
June 30, 2001 Page 15 HazMat Simultest Kit
Draeger Safety
D

Operation of the Kit


l Repeat the sampling
procedure for the other
two Simultest Sets and
evaluate results
l Complete test regimen
for all three Simultest
Sets is accomplished in
less than 5 minutes!
l Even though the
Simultest may present a
negative result the
presence of other
harmful gases cannot
be precluded
DSI Training ©2001
June 30, 2001 Page 16 HazMat Simultest Kit
Draeger Safety
D

Evaluating the Results


l Refer to the laminated cards for quick
interpretation of any color changes in the tubes

l Many of the tubes have two measurement lines to


provide a semi-quantitative determination of
contaminant present
DSI Training ©2001
June 30, 2001 Page 17 HazMat Simultest Kit
Draeger Safety
D

Evaluating the Results


Example: Set I, Tube #4 - Basic Gases

l The first line equates


to 50 ppm and the
second 250 ppm on
the calibrated
substance which is
ammonia
l Other alkaline
substances such as 50 ppm 250 ppm

amines and hydrazine


give a similar color
change, but at slightly
different sensitivities ~50 ppm
DSI Training ©2001
June 30, 2001 Page 18 HazMat Simultest Kit
Draeger Safety
D

Evaluating Color Change; Test Set I


l Tube #5 (5-25 ppm)
w Light Grey to Blue-Grey
l Tube #4 (50-250 ppm)
w Yellow to Blue
l Tube #3 (30-150 ppm)
Unused
w White to Brown-Green
l Tube #2 (10-50 ppm)
w Yellow to Red
l Tube #1 (5-25 ppm)
w Blue to Yellow

Used
DSI Training ©2001
June 30, 2001 Page 19 HazMat Simultest Kit
Draeger Safety
D

Simultaneous Test Sets


l The Test Sets have a two
year shelf life and will be
provided with a date stamp
indicating expiration date
l Old sets are ideal for
training purposes
l Test Sets cannot be reused
once opened
l Disposal of used tube sets
is per relevant governing
body. Draeger offers a
standard letter to assist in
this process if requested.