CIVL-CKL-04-02-01 Earthworks (Buildings) Checklist
CIVL-CKL-04-02-01 Earthworks (Buildings) Checklist
YES NO N/A
1. DESIGN
1.1 Survey available (Drawing and DTM Files)
1.2 WGS co-ordinates system and MSL levels
1.3 Bench marks (at least 2, preferably 3)
Does survey show features on adjoining sites that may affect
1.4
design?
1.5 Are services shown – consider independent check on services:
1.5.1 Sewer (invert)
1.5.2 Roads
1.5.3 Water
1.5.4 Stormwater (invert)
1.5.5 Electricity above / below ground
1.5.6 Telephone above / below ground
1.5.7 Gas / Fuel / oil pipeline
1.6 Check for servitudes over site
1.7 Any other legal restriction or notarial deeds relating to use
1.8 Cadastral boundaries shown and co-ordinates available
1.9 All existing structures shown
1.10 Large trees shown
1.11 Are all watercourses shown?
1.12 Have Geotechnical Engineers been appointed?
1.13 Test pits location given
1.14 Test pits logged
1.15 Indication tests on representative in-situ material
1.16 Depth of refusal
1.17 Observed water table / seepage
1.18 Wet areas
Is material needed to be stockpiled for roads or filling under
1.19
slabs?
1.20 Access point known
1.21 Any natural features to be retained?
Are levels dictated by earthworks balance or are terrace levels
1.22
determined by Architect?
1.23 Spoil site available
1.24 Extra fill material from where?
1.25 Compaction / bulking factor (0,85 – 0,90)
1.26 Depth of topsoil strip (usually 0,1m)
Date:
Rev No. 04 Page 1 of 2
October 2016
1.27 Benching on steep slopes
1.28 Sub-soil drains
1.29 Is temporary drainage needed?
1.30 Does platform terrace slope into hillside?
1.31 Berm provided at top of high fill/cut bank
1.32 Topsoil and grassing specified
1.33 Earthwork quantities (from Civil Designer)
1.34 Compliance with Geotechnical Engineers recommendations
Has an environmental report been carried out and approved by
1.35
LA?
Date:
Rev No. 04 Page 2 of 2
October 2016