Proforma For Determining Energy Efficiency Using R1: Site Name, Address and Grid Reference EPR Permit Reference

1. This document appears to be a proforma for determining the energy efficiency of a site using the R1 factor method. It requests information such as the site name and contact details. 2. The proforma requests operational data for the reporting year, including inputs of fuels, air, flue gases and outputs of electricity, steam and heat. It provides spaces to record the quantity, units and properties of each stream. 3. The proforma will use the input and output data provided to calculate an indicative R1 factor for the site and determine its energy efficiency according to the R1 methodology.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
26 views

Proforma For Determining Energy Efficiency Using R1: Site Name, Address and Grid Reference EPR Permit Reference

1. This document appears to be a proforma for determining the energy efficiency of a site using the R1 factor method. It requests information such as the site name and contact details. 2. The proforma requests operational data for the reporting year, including inputs of fuels, air, flue gases and outputs of electricity, steam and heat. It provides spaces to record the quantity, units and properties of each stream. 3. The proforma will use the input and output data provided to calculate an indicative R1 factor for the site and determine its energy efficiency according to the R1 methodology.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 10

A B C D E F G H I

1 PROFORMA FOR DETERMINING ENERGY EFFICIENCY USING R1

Site name, address and EPR Permit


2
grid reference reference
(if known)

3 Operator name Application fee (£)

Details of who to
4
contact if we have any
queries regarding this
form

5
What data has been used in the application? → Design data
Indicative R1 factor (subject Quantity in Units Uc Properties Units Note which Reference to
6 to confirmation) #DIV/0! reporting (Average over parameters that Supporting
year reporting year) have been estimated information
7
Climate change correction
factor (optional)
R1 after CCF adjustment
8

9 1. Gross electricity meter (Electricity produced at turbine) MWh


10 2. Electricity exported - Net input/output meter MWh
11 3. Electricity imported - Net input/output meter MWh
12 4. Other fuel inputs
13 4.1 Light fuel oil litres 0.93 kg/l
14 42800 kJ/kg
15 4.2 Natural gas Nm 3
34200 kJ/Nm3
16
17 4.3 LPG Nm3 kg/Nm3
18 kJ/kg
19 4.4 Other fuels similar to light fuel oil litres kg/l
20 kJ/kg
21 5. Primary combustion air (as supplied to furnace) m3 kg/Nm3
22 °C
23 0 kJ/kg
24 6. Secondary combustion air (as supplied to furnace) m3 kg/Nm3
25 °C
26 0 kJ/kg
27 7. Recycled flue gas (as supplied to furnace) m3 kg/Nm3
28 °C
29 0 kJ/kg
30 8. Heat exported outside R1 boundary
31 8.1 steam exported tonnes °C
32 kPa
33 kJ/kg
34 condensate returned tonnes °C
35 kPa
36 kJ/kg
37 8.2 hot water exported tonnes °C
38 kPa
39 kJ/kg
40 hot water returned tonnes °C
41 kPa
42 kJ/kg
43
44 9. Internal steam use
45 9.1 for soot blowing (no backflow) tonnes °C
46 kPa
47 kJ/kg
48 9.2 for steam driven devices tonnes °C
49 kPa
50 kJ/kg
51 backflow as steam tonnes °C
52 kPa
53 kJ/kg
54 9.3 for trace heating tonnes °C
55 kPa
56 kJ/kg
57 backflow as condensate tonnes °C
58 kPa
59 kJ/kg
60 9.4 for re-heating flue gas tonnes °C
61 kPa
62 kJ/kg
63 backflow as condensate tonnes °C
64 kPa
65 kJ/kg
66 9.5 for concentration processes tonnes °C
67 kPa
68 kJ/kg
69 backflow as condensate tonnes °C
70 kPa
71 kJ/kg
72 9.6 for building, equipment, tank heating tonnes °C
73 kPa
74 kJ/kg
75 backflow as condensate tonnes °C
76 kPa
77 kJ/kg
A B C D E F G H I
78 9.7 for deaeration and demineralisation tonnes °C
79 kPa
80 kJ/kg
81 backflow as condensate tonnes °C
82 kPa
83 kJ/kg
84 9.8 other internal applications, in line with tonnes °C
85 commission guidance, to be specified kPa
86 kJ/kg
87 backflow as condensate tonnes °C
88 kPa
89 kJ/kg
90 9.9 other internal applications, in line with tonnes °C
91 commission guidance, to be specified kPa
92 kJ/kg
93 backflow as condensate tonnes °C
94 kPa
95 kJ/kg
96 10. Use of condensing energy from steam in flue gas GJ
97 11. Superheated steam at boiler outlet tonnes °C
98 kPa
99 kJ/kg
100 12. Boiler feedwater tonnes °C
101 kPa
102 kJ/kg
103 13. Boiler Efficiency (Design) ± 1.5%
104 Instructions for completing this spreadsheet
105 1. Ensure that you have completed the first three rows of the application form
2. This form should be accompanied by supporting information for the figures quoted. Where this information is in the permit application, reference to the
106
relevant sections of the application can be made.
A Sankey diagram (or equivalent) reflecting the boundaries of the installation used as well as any references to physical properties is the absolute
107
minimum that should be provided for an application based on design information
3. We have colour coded the cells in this spreadsheet to assist you in completing this form, an explanation of the colour codes is provided below. The
108
colour will disappear when data has been entered.
109
Blue cells require data that is essential for the R1 calculation, where information on uncertainty of the data is available it would be useful (but not
mandatory) for this to be included for these parameters.
Beige Cells indicate that any data entered will be used in the R1 calculation. They have been used where there is a choice of inputs but not all plants will
110
have data for all the input options.
Where you are entering data into beige cells you need to make sure that you enter data into all the beige cells associated with the input as they are all
111
needed for carrying out the calculation.
Yellow cells have been used to provide flexibility to include fuels or energy uses not identified elsewhere. Supporting information to explain why the
112
standard fields were not appropriate or adequate will need to be provided where these cells are used.
113 Data entered in uncoloured cells are not used when calculating the R1 energy efficiency factor but can be completed to provide a more complete data
set.
114 Data in the purple cell for the CCF factor is optional. If used the way it was calculated must be explained in supporting information
115 4. Ensure the temperatures entered into cells F19 and F22 (and F25) are the actual temperatures of the heated air in oC.
116 The spreadsheet uses these values to calculate the specific enthalpy associated with heating the air from ambient 25 oC in cells F20 and F23 (and F26).
117 5. Densities used in cells F18 and F21 (and F24) should be at the temperatures at which the flows quoted in C18 and C21 (and C24) are reported.
118 The spreadsheet multiplies these pairs of entries to generate a mass of air.

119
6. If you believe that any of the information that you have submitted in this application form is commercially confidential please identify the confidential
information and the grounds on which you believe it to be confidential in your covering letter
LIT 5753
120

EAD/0812/xls/v3
121
Ep (detailed) 0
Ef + Ei 0
Ew + Ef #DIV/0!
R1 #DIV/0!
CCF 0
Adjusted R1 #DIV/0!
Quantity Uc
in
reporting
year
Gross electricity meter (Electricity produced at turbine) 0 MWh
Electricity exported - Net input/output meter 0 MWh
Heat exported outside R1 boundary 0 GJ
steam exported 0 tonnes
condensate returned 0 tonnes
hot water exported 0 tonnes
hot water returned 0 tonnes

Internal steam use 0 GJ


for soot blowing (no backflow) 0 tonnes
for steam driven devices 0 tonnes
backflow as steam 0 tonnes
for trace heating 0 tonnes
backflow as condensate 0 tonnes
for re-heating flue gas 0 tonnes
backflow as condensate 0 tonnes
for concentration processes 0 tonnes
backflow as condensate 0 tonnes
for building, equipment, tank heating 0 tonnes
backflow as condensate 0 tonnes
for deaeration and demineralisation 0 tonnes
backflow as condensate 0 tonnes
other internal applications to be specified 0 tonnes
backflow as condensate 0 tonnes
other internal applications to be specified 0 tonnes
backflow as condensate 0 tonnes

Use of condensing energy from steam in flue gas 0 GJ

Backflows of condensate GJ
Condensate after cooling tonnes
Boiler feedwater tonnes

Ep 0
Average Uc Uc Uncertaint
during y
operation
over year

0 K 0 kPa 0 kJ/kg
0 K 0 kPa 0 kJ/kg
#REF! K 0 kPa 0 kJ/kg
0 K 0 kPa 0 kJ/kg

K kPa 0 kJ/kg
K kPa 0 kJ/kg
K kPa 0 kJ/kg
K kPa 0 kJ/kg
K kPa 0 kJ/kg
K kPa 0 kJ/kg
K kPa 0 kJ/kg
K kPa 0 kJ/kg
K kPa 0 kJ/kg
K kPa 0 kJ/kg
K kPa 0 kJ/kg
K kPa 0 kJ/kg
K kPa 0 kJ/kg
K kPa 0 kJ/kg
K kPa 0 kJ/kg
K kPa 0 kJ/kg
K kPa 0 kJ/kg

K kPa kJ/kg
K kPa kJ/kg
Quantity in Uc
reporting
year
Electricity imported - Net input/output mete 0 MWh
Other fuel inputs 0 GJ
Light fuel oil 0 litres 0.93 kg/l
Natural gas 0 Nm3 34200 kJ/Nm3
LPG 0 Nm3 0 kg/Nm3
Other fuels similar to light fuel oil 0 litres 0 kg/l

Ef + Ei 0 GJ
42800 kJ/kg

0 kJ/kg
0 kJ/kg
Quantity Uc Average Uc
in during
reporting operation
year over year
Superheated steam at boiler outlet 0 tonnes 0 K
Boiler feedwater 0 tonnes 0 K
Primary combustion air (heated) 0 Nm3 0 K
Secondary combustion air (heated) 0 Nm3 0 K
Recirculated flue gas 0 Nm3 0 K

Energy of steam 0 GJ per annum


Energy of feedwater 0 GJ per annum
Energy of combustion air 0 GJ per annum
Boiler Efficiency 0% ± 1.5%
Ew+Ef #DIV/0! GJ per annum
Uc Uc

0 kPa 0 kJ/kg
0 kPa 0 kJ/kg
0 kg/Nm3 0 kJ/kg #REF!
0 kg/Nm3 0 kJ/kg #REF!
0 kg/Nm3 0 kJ/kg
Version Created byChanges made Date
1 CDM Original to be used as a guide 8/19/2011
Colour coding essential cells and
2.1 CDM introducing the notes at the bottom 10/31/2011
Removed section 10, added FGR and
2.2 CDM included indicative properties 12/31/2011
Added title, and modified sections 5,6
and 7 so that they did not return negative
2.3 CDM values 9/9/2012
Amended EP tab to avoid double
counting condensate return. Added note
2.4 MBJ to input page. Cell colours amended 9/4/2015
Climate change factor added. Changes
to admin section including section on
3.0 MBJ application fee paid. 8/18/2016