Type AF by Lindapter 1226
Type AF by Lindapter 1226
Type AF
A heavy duty clamp offering the highest load capacities
of all Lindapter’s High Slip Resistance clamps.
Hot dip galvanised corrosion protection.
Recess
Type AF + AFW
Type AFW (page 16)
GIRDER CLAMPS
HIGH SLIP
RESISTANCE
RAIL FIXINGS
V1 V2
Y X
LIFTING POINTS
• High slip resistance for tensile, frictional and combined load applications.
• 70kN static slip resistance or 250kN tensile (AF24 with 4 x property
class 10.9 fasteners.
• Recess holds the bolt head captive (property class 8.8).
HOLLO-BOLT
Packings are available to increase the clamping range, see page 16. Location plate / end plate details can be found on page 17.
Lindapter recommends the use of DTI Washers conforming to EN14399-9 with the Type AF.
For further information please refer to page 70.
USA Seismic Approval
See ESR-3976
FLOOR FIXINGS
Product Size Property Tensile / 1 Bolt Slip 1) / 2 Bolts Tightening Tail Y X T T Width
Code Z Class4) (FOS 5:1) (FOS 2:1) Torque* Length
Painted Galvanised short medium Type Type AF
Steelwork2) Steelwork V1 V2 AF with AFW
kN kN kN Nm mm mm mm mm mm mm mm
SUPPORT FIXINGS
For Characteristic Resistances when designing a connection to Eurocode 3, please refer to DoP No.004 on the website www.Lindapter.com/About/CE
®
+44 (0) 1274 521444 www.Lindapter.com © Lindapter International 2019
16 | Girder Clamps by Lindapter ®
AFP2 / AAFP3 T
T T
Z Z Z
Mild steel, hot dip galvanised. Mild steel, hot dip galvanised. SG iron, mild steel, hot dip galvanised.
RAIL FIXINGS
Product Bolt Size Dimension Product Bolt Size Dimension Product Bolt Size Dimension
Code Z T (mm) Code Z T (mm) Code Z T (mm)
* Also compatible with Type AAF clamp. AF24P1 M24 5 AFW24 M24 10
Note: The AFCW has a slight bend along its centre AF12P2* M12 10 Note: The Type AFW is used to fill the recess in the
LIFTING POINTS
line which flattens out during installation. Type AF to convert it into a flat top clamp to enable
AF16P2* M16 10 the bolt head or nut to be rotated on a hardened
AF20P2 M20 10 washer. The Type AFW is also required when using
pre-loadable bolts to BS EN 14399 due to their
AF24P2 M24 10 larger hexagon heads.
AAF20P3* M20 20
* Also compatible with Type AAF clamp.
HOLLO-BOLT
Flange M12 M16 M20 M24 Flange M12 M16 M20 M24
Thickness Thickness
mm AF AFCW AFP1 AFP2 AF AFCW AFP1 AFP2 AF AFCW AFP1 AFP2 AF AFP1 AFP2 mm AF AFCW AFP1 AFP2 AF AFCW AFP1 AFP2 AF AFCW AFP1 AFP2 AF AFP1 AFP2
5 S - - - - - - - - - - - - - - 28 M - 1 1 S - - 2 M - - 1 M - -
6 S - - - - - - - - - - - - - - 29 M 1 1 1 M - 1 1 M - - 1 M - -
7 S 1 - - S - - - - - - - - - - 30 S - 1 2 M - 1 1 M 1 - 1 M - -
8 S 1 - - S - - - - - - - - - - 31 S - 1 2 M - 1 1 M 1 - 1 M - -
9 S 2 - - S - - - S - - - - - - 32 M - - 2 M 1 1 1 M - 1 1 M 1 -
10 S - 1 - S 1 - - S - - - - - - 33 M - - 2 M 1 1 1 M - 1 1 M 1 -
11 S 3 - - S 1 - - S - - - - - - 34 M 1 - 2 M - - 2 M - 1 1 M 1 -
SUPPORT FIXINGS
12 S 1 1 - S 2 - - S 1 - - S - - 35 S - - 3 M - - 2 S - 1 2 M 1 -
13 M - - - S - 1 - S 1 - - S - - 36 S - - 3 M - - 2 M 1 1 1 M 1 -
14 M 1 - - S 3 - - S 2 - - S - - 37 M - 1 2 M 1 - 2 M - - 2 M 1 -
15 S - - 1 M - - - S - 1 - S - - 38 M - 1 2 S - - 3 M - - 2 M - 1
16 M 2 - - M - - - S 3 - - S - - 39 M 1 1 2 M - 1 2 M - - 2 M - 1
17 M - 1 - M 1 - - M - - - S - - 40 S - 1 3 M - 1 2 M 1 - 2 M - 1
18 M - 1 - S - - 1 M - - - S 1 - 41 S - 1 3 M - 1 2 M 1 - 2 M - 1
19 M 1 1 - M - 1 - M - - - S 1 - 42 M - - 3 M 1 1 2 M - 1 2 M - 1
20 S - 1 1 M - 1 - M 1 - - S 1 - 43 M - - 3 S - 1 3 M - 1 2 M 1 1
21 M 2 1 - M - 1 - M 1 - - S 1 - 44 M 1 - 3 M - - 3 M - 1 2 M 1 1
22 M 2 1 - M 1 1 - M 2 - - S 1 - 45 S - - 4 M - - 3 M 1 1 2 M 1 1
DECKING FIXINGS
23 M - - 1 M 1 1 - M - 1 - S - 1 46 S - - 4 M - - 3 M 1 1 2 M 1 1
24 M 1 - 1 M - - 1 M 1 1 - S - 1 47 M - 1 3 M 1 - 3 M - - 3 M 1 1
25 S - - 2 M - - 1 M 1 1 - S - 1 48 M - 1 3 S - - 4 M - - 3 M - 2
26 M 2 - 1 M - - 1 S 1 1 1 S - 1 49 S - 1 4 M - 1 3 M - - 3 M - 2
27 M 2 - 1 M 1 - 1 S 1 1 1 M - - 50 S - 1 4 M - 1 3 M 1 - 3 M - 2
AF = Type AF | AFCW = Type AFCW | AFP1 = Type AFP1 | AFP2 = Type AFP2 | S = AF short | M = AF medium
®
+44 (0) 1274 521444 www.Lindapter.com © Lindapter International 2019
Girder Clamps by Lindapter ® | 17
Location Plate
GIRDER CLAMPS
What is it?
Location plates are simple fabricated PLATE DIMENSIONS
items designed to sit between the L1 = Plate Length, L2 = Plate Width,
B1, B2 = Flange Width, C1, C2 = Hole Centres, d = Hole Ø
two sections to be clamped together
to ensure the bolts are fixed at the
L1
correct centres.
C1
RAIL FIXINGS
Material: Structural steel grade S355 JR, JO or J2.
For other grades contact Lindapter.
LIFTING POINTS
M12 14 10 12 B1 + 14 B1 + 90 B2 + 14 B2 + 90
M16 18 15 15 B1 + 18 B1 + 110 B2 + 18 B2 + 110 d
M20 22 20 20 B1 + 22 B1 + 150* B2 + 22 B2 + 150*
M24 26 25 25 B1 + 26 B1 + 180 B2 + 26 B2 + 180 B1
* Plate length / width for Type AF size M20 can be reduced to 130mm if required.
HOLLO-BOLT
End Plate
What is it?
End plates are simple fabricated PLATE DIMENSIONS
items that are pre-welded to support L1 = Plate Length, L2 = Plate Width,
B = Flange Width, C1, C2 = Hole Centres, d = Hole Ø
frames, bracket or sections, allowing
connection to the supporting structure
L1
FLOOR FIXINGS
with standard Lindapter clamps.
C1
C2 L2
d 8.8 10.9 C1 min L1 min C2 min L2
mm mm mm mm mm mm mm
d
M12 14 15 20 B + 14 B + 90 80 C2 + 80
M16 18 20 25 B + 18 B + 110 100 C2 + 100
M20 22 25 25 B + 22 B + 150* 180 C2 + 180
M24 26 30 30 B + 26 B + 180 200 C2 + 200 B
DECKING FIXINGS
* Plate length for Type AF size M20 can be reduced to 130 if required.
1) Depending on the type of connection and associated end plate use, the thickness may need to be modified to comply with accepted local design codes.
To calculate the bolt length, add up the total distance that the bolt will pass through, plus half of the bolt diameter.
Then round up the total to the nearest available bolt length. An example can be found on page 6.
®
© Lindapter International 2019 www.Lindapter.com +44 (0) 1274 521444