Diesel Generator Set C600D6: 750 kVA Standby - 60Hz
Diesel Generator Set C600D6: 750 kVA Standby - 60Hz
Diesel
generator set
C600D6
750 kVA standby - 60Hz
Description
This Cummins Power Generation commercial Cooling system – Standard integral set mounted
generator set is a fully integrated power radiator system, designed and tested for rated
generation system providing optimum ambient temperatures, simplifies facility design
performance, reliability, and versatility for requirements for rejected heat.
stationary standby, prime power, and continuous
duty applications. Control system – Standard PowerCommand®
electronic control provides total system integration
Features including remote start/stop, precise frequency and
Cummins® medium-duty engine - voltage regulation, alarm and status message
Rugged 4-cycle industrial diesel delivers reliable display, AmpSentry protection, output metering,
power, and fast response to load changes. auto-shutdown.
Power rating
cumminspower.com
©2015 Cummins Power Generation Inc. | BRS-00006a-EN (11/2015)
Generator set specifications
Governor regulation class ISO 8528 Class G3
Voltage regulation, no load to full load ± 0,5%
Random voltage variation ± 0,5%
Frequency regulation Isochronous
Random frequency variation ± 0.25%
Radio frequency emissions compliance BS EN 61000-6-4 / BS EN 61000-6-2
Engine specifications
Standby rating Prime rating
Engine manufacturer Cummins
Engine model VTA28-G5
Design 4 cycle, turbo charged and after cooled
Gross engine power output, kWm 671 608
BMEP at set rated load, kPa 1599 1448
Bore, mm (in) 139.7 (5.5)
Stroke, mm (in) 152.4 (6.0)
Displacement, L (in³) 28 (1710)
Cylinder block Cast iron with replaceable wet cylinder liners, 40° V12 cylinder
Battery capacity, Amp/hour 4 x 100
Battery charging alternator, Amp 35
Starting voltage, VDC 24, negative ground
Fuel filter Fuel filter with water separator
Lube oil capacity, L 83
Governor Type Electronic
Air
Combustion air, m3/min 64.60 58.50
Maximum air cleaner restriction, kPa 6.2
Exhaust
Exhaust gas flow at set rated load, m3/min 142.8 131.3
Exhaust gas temperature, °C 502 474
Maximum exhaust back pressure, kPa 10.2
Fuel flow
Maximum fuel flow, L/hr 337
Maximum fuel inlet restriction, mm Hg 203
Maximum fuel inlet temperature, °C 70
Fuel consumption
Standby rating Prime rating Continuous rating
Load Full 3/4 1/2 1/4 Full 3/4 1/2 1/4 Full 3/4 1/2 1/4
US Gal/h 45.7 34.5 24 13.7 40.7 31.2 22.2 13.1 32.1 24.2 17.0 10.0
L/hour 173 130 91 52 154 118 84 50 122 91 64 38
cumminspower.com
©2015 Cummins Power Generation Inc. | BRS-00006a-EN (11/2015)
Alternator specifications
Design Brushless, 4 pole, drip proof, revolving field
Stator 2/3 pitch
Rotor Direct coupled by flexible disc
Insulation system Class H
Standard temperature rise 150 ºC (302 °F) at standby
Exciter type PMG (permanent magnet generator)
Phase rotation A (U), B (V), C (W)
Alternator cooling Direct drive centrifugal blower
AC waveform total harmonic distortion (THDV) < 5% no load to full linear load
Available voltages
60 Hz line-neutral / line - line
3-phase 1-phase
• 120/208 • 230/400 • 277/480 • N/A
• 127/220 • 240/416
• 220/380 • 255/440
Weights*
Open Enclosed
Unit dry weight, kg 5630 RTF
Unit wet weight, kg 5839 RTF
* Weights represent a set with standard features. See outline drawing for weights of other configurations.
Dimensions
Dim “A” Dim “B” Dim “B”
Standard open set dimensions, mm 3934 1468 2179
Enclosed set standard dimensions, mm RTF RTF RTF
Genset outline
Open set
Enclosed set
Outlines are for illustrative purposes only. Please refer to the genset outline drawing for an exact representation of this model.
cumminspower.com
©2015 Cummins Power Generation Inc. | BRS-00006a-EN (11/2015)
Ratings definitions
Emergency standby power (ESP): Prime power (PRP):
Applicable for supplying power to varying electrical load for the Applicable for supplying power to varying electrical load for
duration of power interruption of a reliable utility source. unlimited hours. Prime Power (PRP) is in accordance with ISO
Emergency Standby Power (ESP) is in accordance with ISO 8528. 8528. Ten percent overload capability is available in accordance
Fuel Stop power in accordance with ISO 3046, AS 2789, DIN with ISO 3046, AS 2789, DIN 6271 and BS 5514.
6271 and BS 5514.
Base load (continuous) power (COP):
Limited-time running power (LTP): Applicable for supplying power continuously to a constant
Applicable for supplying power to a constant electrical load for electrical load for unlimited hours. Continuous Power (COP) in
limited hours. Limited Time Running Power (LTP) is in accordance with ISO 8528, ISO 3046, AS 2789, DIN 6271 and
accordance with ISO 8528. BS 5514.
Certifications
This generator set is designed in facilities
certified to ISO 9001 and manufactured in
facilities certified to ISO 9001.
South America North America Asia Pacific Europe, CIS, Middle East and Africa
Rua Jati, 310, Cumbica 1400 73rd Avenue N.E. 10 Toh Guan Road #07-01 Manston Park Columbus Ave.
Guarulhos, SP Minneapolis, MN 55432 USA TT International Tradepark Manston, Ramsgate
07180-900 Phone 763 574 5000 Singapore 608838 Kent CT12 5BF
Brazil Fax 763 574 5298 Phone 65 6417 2388 United Kingdom
Phone 0800 286 6467 Fax 65 6417 2399 Phone 44 1843 255000
Fax 44 1843 255902