0% found this document useful (0 votes)
735 views

Tabulation of Building Laws

The document tabulates design standards from several Philippine laws and ordinances related to building construction. It outlines requirements for residential buildings, including foundation thickness, occupant load calculations, stair dimensions, ceiling heights, window sizes, room dimensions, exit requirements, and more. The standards cover topics such as structural design, fire safety, subdivision planning, and accessibility.

Uploaded by

Anghelikaaa
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
735 views

Tabulation of Building Laws

The document tabulates design standards from several Philippine laws and ordinances related to building construction. It outlines requirements for residential buildings, including foundation thickness, occupant load calculations, stair dimensions, ceiling heights, window sizes, room dimensions, exit requirements, and more. The standards cover topics such as structural design, fire safety, subdivision planning, and accessibility.

Uploaded by

Anghelikaaa
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Tabulation of Design Standards: P.D 1096: Building Code, P.D. 1185: Fire Code, P.D.

957: Subdivision &


Condominium Law, B.P. 220: Economic & Socialized Housing & B.P. 344: Accessibility Law

P.D 957
Subject P.D 1096 P.D 1185 Subdivision & B.P 220 B.P 220 B.P 344
Building Code Fire Code Condominium Economic Socialized Accessibility
Law Housing Housing Law
Residential
Requirements
Corner Lot Maximum of 90% of N/A N/A N/A N/A N/A
the lot
Inside Lot Maximum of 80% of N/A N/A N/A N/A N/A
the lot
At least 250 mm N/A N/A N/A N/A N/A
Foundation thick, 600 mm
below ground
surface
Occupant Load 18.6 sq. m/ person N/A 18.6 sq. m/ person No. of units No. of units N/A
Multiplied by 6 Multiplied by 6
Live Load @ 1st At least 200 kg. / N/A N/A N/A N/A N/A
floor sq. .m
Live Load @ 2nd At least 150 kg. / N/A N/A N/A N/A N/A
floor sq. m
Stair Width At least 750 mm N/A 1.10 m 600 mm 600 mm
Stair Riser Max. of 200 mm N/A 200 mm 200 mm 200 mm
Stair Tread At least 200 mm N/A 250 mm 250 mm 250 mm
Refer to Fire N/A
Entrance & Exit At least 1 entrance Code At least 1 entrance At least 1 entrance At least 1 entrance
& 1 exit Specifications & 1 exit & 1 exit & 1 exit
(Too many to
tabulate)

1
Light & P.D 957
Ventilation P.D 1096 P.D 1185 Subdivision & B.P 220 B.P 220 B.P 344
Building Code Fire Code Condominium Economic Socialized Accessibility
Law Housing Housing Law
Min. dimension of 2.00 m N/A 1.50 m 2.00 m 2.00 m N/A
court
Passageway from At least 1.20 m N/A At least 1.20 m At least 1.20 m At least 1.20 m N/A
Inner Court
Min. Ht. Clearance 1.00 m above the N/A 1.00 m above the 1.00 m above the 1.00 m above the N/A
from Firewall roof roof roof roof
Headroom 2.00 m 2.00 m 2.00 m 2.00 m 2.00 m N/A
Clearance
Min. Ceiling Ht. 2.40 m – Artificial 2.40 m – Artificial
for Habitable Ventilation 2.30 m Ventilation 2.40 m 2.40 m N/A
Rooms 2.70 m – Natural 2.70 m – Natural
Ventilation Ventilation

Min. Ceiling Ht. 2.70 m – 1st Storey


for Buildings 2.40 m – 2nd Storey 2.30 m N/A
2.10 m – Succeeding 2.00 m 2.00 m 2.00 m
Storeys 1.80 m - Mezzanine 1.80 m - Mezzanine 1.80 m - Mezzanine
1.80 m – Mezzanine 2.13 m

Sum of Areas of Less than 50% of Less than 50% of Less than 25% of Less than 25% of
Openings in any total area of the wall N/A total area of the total area of the total area of the N/A
Storey on that storey wall on that storey wall on that storey wall on that storey

Window Openings At least 10% of the N/A At least 10% of the At least 10% of the At least 10% of the N/A
floor area floor area floor area floor area
Eaves over At least 750 mm N/A N/A N/A N/A N/A
required windows

2
P.D 957
Size/ Dimension P.D 1096 P.D 1185 Subdivision & B.P 220 B.P 220 B.P 344
of Rooms Building Code Fire Code Condominium Economic Socialized Accessibility
Law Housing Housing Law
Rooms for Human 6.00 sq. m w/ min. N/A 18 sq. m for studio N/A N/A N/A
Habitation dimension of 2.00 m unit
Kitchens 3.00 sq. m w/ min N/A N/A N/A N/A N/A
dimension of 1.50 m
Toilet & Bath 1.20 sq. m w/ min. N/A N/A N/A N/A 2.25 sq. m
dimension of 0.90 m
Exits P.D 957
P.D 1096 P.D 1185 Subdivision & B.P 220 B.P 220 B.P 344
Building Code Fire Code Condominium Economic Socialized Accessibility
Law Housing Housing Law
Occupant Load of At least 1 exit At least 2 exits At least 1 exit At least 1 exit At least 1 exit N/A
less than 10
Occupant Load of At least 2 exits N/A At least 2 exits N/A N/A N/A
10-499
Occupant load of At least 3 exits N/A At least 3 exits N/A N/A N/A
500-999
Occupant Load of At least 4 exits N/A At least 4 exits N/A N/A N/A
1000-above
Distance to exits
without Sprinkle Max. of 45 m Max. of 46 m Max. of 45 m Max. of 45 m Max. of 45 m N/A
System
Distance to exits
with Sprinkle Max. of 60 m Max. of 61 m Max. of 60 m Max. of 60 m Max. of 60 m N/A
System
Min. exit door 700 mm 710 mm 700 mm 800 mm 800 mm N/A
width
Min. exit door 2.00 m 2.00 m 2.00 m 2.00 m 2.00 m N/A
height
Min. corridor 1.10 m 550 mm 1.10 m 1.20 m 1.20 m 1.20 m
width
Max. slope of 1:8 N/A 1:8 1:8 1:8
passageway
Dead ends Max. of 6.00 m Max. of 6.00 m Max. of 12.00 m Max. of 12.00 m Max. of 12.00 m N/A

3
P.D 957
Stairways for P.D 1096 P.D 1185 Subdivision & B.P 220 B.P 220 B.P 344
Buildings Building Code Fire Code Condominium Economic Socialized Accessibility
Law Housing Housing Law
Min. stair width: 750 mm N/A N/A N/A N/A N/A
Occupant load of
10-below
Min. stair width: 900 mm N/A 900 mm 900 mm 900 mm N/A
Occupant load of
10-50
Min. stair width: 1.10 m N/A 1.10 m 1.00 m 1.00 m N/A
Occupant load of
50 - above
Riser 200 mm 190 mm class A 200 mm 200 mm 200 mm N/A
200 mm class B
Tread 250 mm 250 mm class A 250 mm 250 mm 250 mm N/A
230 mm class B
Min. width 1.10 m 1.12 m 1.10 m 600 mm 600 mm N/A
Distance bet. 3.60 m 2.75 m class A 3.60 m 3.60 m 3.60 m N/A
Landings 3.70 m class B
Dimension of Equal to the width of 1.12 m Equal to the Equal to the width of Equal to the width N/A
Landings in the the stairway width of the the stairway of the stairway
direction of travel stairway
Height of 800-900 mm from 760-895 mm 800-900 mm 800-1200 mm from 800-1200 mm 700-800 mm
handrails the nosing from the nosing from the nosing the nosing from the nosing from the floor
Sidewalks & P.D 957
Arcades P.D 1096 P.D 1185 Subdivision & B.P 220 B.P 220 B.P 344
Building Code Fire Code Condominium Economic Socialized Accessibility
Law Housing Housing Law

Min. of width of 1/6 of R.O.W N/A 1.00 m for 1.00 m for major 1.00 m for major
sidewalk major road & road & 500 mm road & 500 mm N/A
minor roads minor road minor road

Plan Strip 800 mm for N/A 1.00 m for major 1.00 m for major 1.00 m for major N/A
sidewalks exceeding road & minor road & 500 mm road & 500 mm
2.00 m in width roads minor road minor road

4
Driveways,
Entrance & Exits
Slope of entryway 1:3 or 1:4 N/A 1:3 or 1:4 N/A N/A N/A

Max. slope of 1:10 10% 1:10 15% 15% 1:12 but


ramps length shall not
exceed 6.00 m
w/o landing
Open Space
Requirements
Interior Lots 50% Residential N/A 50% Residential 50% Residential 50% Residential N/A
25% others 25% Others 25% Others 25% Others
Inside Lots 20% Residential N/A 20% Residential 20% Residential 20% Residential N/A
15% others 15% Others 15% Others 15% Others

Corner/Through 10% Residential N/A 10% Residential 10% Residential 10% Residential N/A
Lot 5% others 5% Others 5% Others 5% Others
Lot bounded by 5% for all N/A 5% for all 5% for all 5% for all N/A
streets on 3 sides occupancies Occupancies Occupancies Occupancies
P.D 957
Setbacks P.D 1096 P.D 1185 Subdivision & B.P 220 B.P 220 B.P 344
Building Code Fire Code Condominium Economic Socialized Accessibility
Law Housing Housing Law
Low Density 5.00 m Front
Residential (R-1) 2.00 m Side N/A N/A N/A N/A N/A
2.00 m Rear
Medium Density 3.00 m Front
Residential (R-2) 2.00 m Side N/A N/A N/A N/A N/A
2.00 m Rear
High Density 2.00 m Front 3.00 m Front 1.5 m Front 1.5 m Front
Residential (R-3) 2.00 m Side N/A 2.00 m Side 2.00 m Side 2.00 m Side N/A
2.00 m Rear 2.00 m Rear 2.00 m Rear 2.00 m Rear

5
Parking

Size of Parking 2.40 x 5.00 m 2.40 x 5.00 m 2.40 x 5.00 m 2.40 x 5.00 m
Slot (perpendicular & (perpendicular & (perpendicular & (perpendicular &
diagonal) N/A diagonal) diagonal) diagonal) 3.70 x 5.00 m
2.00 x 6.00 m 2.00 x 6.00 m 2.00 x 6.00 m 2.00 x 6.00 m
(parallel) (parallel) (parallel) (parallel)
Low-income
single detached Pooled Parking 1 N/A Pooled Parking 1 Pooled Parking 1 Pooled Parking 1 N/A
living units w/ slot/ 10 units slot/ 10 units slot/ 10 units slot/ 10 units
individual lot size
not more than
100 sq. m
50 sq. m below 1 slot /8 units 1 slot /8 units
50-100 sq. m 1 slot/ 4 units N/A 1 slot/ 4 units 1 slot / 20 units 1 slot / 20 units N/A
100 sq. m above 1 slot/ 1 unit 1 slot/ 1 unit

You might also like