Instructions For Using USB To CAN
Instructions For Using USB To CAN
CAN Settings
Work patterns include normal mode, Loop back mode, silent mode, Loop
Loop back mode: send data CAN be sent to CAN bus, and at the same
Silent mode: CAN normal accept data, but CAN only send recessive
position, and CAN't really send message, often is applied to the analysis
namely online self test. Like a ring back mode that self test, but does not
29 ID)
CAN baud rate: CAN the direct selection CAN communication commonly
1M,800K,500K,400K,250K,200K,125K,100K,50K,20K,10K,5K
f it CAN be directly set the baud rate and you CAN equipment baud rate
Fixed 20 bytes to send and receive: CAN converter internal there are
is not selected
Manual set bps: After the choice will jump out of a custom baud rate
dialog box
The title will show the formula for the calculation of the CAN baud rate
The top position CAN baud rate calculation formula, and at the same time
set phase buffer 1, phase buffer 2, and preassigned frequency is ok
Filter ID and Mask ID: are hexadecimal data filtering the IDs and Mask ID
standard frames low 11 (range: 0x00000000 to 0x000007ff) extended frame
filter ID and Mask ID 29 (range 0x00000000 to 0x1fffffff)
automatic repeat, if have been circulating send data, CAN set banned