Design procedures in seismic load computation are based from the National Structural
Code of the Philippines 2015, 7th Edition, Section 208. The step-by-step seismic load
Seismic Parameters:
Occupancy Category
IV (Standard Occupancy Structures) (Table 103-1, NSCP 2015)
Soil Profile Type
SD (Table 208-2, NSCP 2015)
Seismic Importance Factor
I=1 (Table 208 – 1, NSCP 2015)
Seismic Zone Factor
z = 0.4 (Zone 4) (Table 208-3, NSCP 2015)
Seismic Source Type
Type C (Table 208-4, NSCP 2015)
Near Source Factor;
Na = 1.0 (Table 208-5, NSCP 2015)
Nv = 1.0 (Table 208-6, NSCP 2015)
Seismic coefficient;
Ca = 0.44Na (Table 208-7, NSCP 2015)
Cv = 0.64Nv (Table 208-8, NSCP 2015)
R = 8.5 (Table 208-11C, NSCP 2015)
Frame Material Factor;
Ct = 0.0731 (Section 208.5.2.2, NSCP 2015)
Dead Load:
Ground Floor = 5406.23 kN
Second Floor = 5455.69 kN
Third Floor = 5455.69 kN
Fourth Floor = 5455.69 kN
Roof Deck = 2440.92 kN
Total Dead Load = 24214.24 kN
T = 0.0731 (13.3) ¾
Cv I (0.64)(1)(1)
V actual = (W ) = ( 24214.24 ) = 3581.18 kN
RT (8.5)(0.5091)
2.5CaI (0.25)(0.44)(1)(1)
V max = ( W )= ( 24214.24 ) = 3133.61 kN
R ( 8.5)
( 3133.61−0 )(32464.26)
F i 5= =519.07 kN
195986.63
( 3133.61−0 ) (65468.27)
F i4 = =1046.77 kN
195986.63
( 3133.61−0 )(49101.20)
F i 3= ¿ 785.07 kN
195986.63
( 3133.61−0 ) (32734.14 )
F i 2= ¿ 523.38 kN
195986.63
( 3133.61−0 ) (16218.77)
F i 1= ¿ 259.32 kN
195986.63
Vx=Ft + Fx
V 5=0+519.07=519.07 kN
V 4 =519.07+1046.77=1565.84 kN
V 3=1565.84 +785.07=2350.91kN
V 2=2350.91+523.38=2874.29 kN
V 1=2874.29+259.32=3133.61 kN
M 5=519.07(3)=1556.20 kN .m
M 4 =519.07 ( 6 ) +1565.83(3)=7811.9 0 kN .m
The summary of the calculation of seismic forces for the proposed four-storey dwelling
unit is shown in Table #.
Table #
Calculation of Seismic Forces
Level hx (m) Wx (kN) Wxhx Fx +Ft Vx Mx
Roof Deck 13.3 2440.92 32464.56 519.07 519.07 1557.20
4 12 5455.69 65468.27 1046.77 1565.84 7811.90
3 9 5455.69 49101.20 785.07 2350.91 21119.31
2 6 5455.69 32734.14 523.38 523.38 43049.60
1 3 5406.26 16218.77 259.32 3133.61 59132.84
∑ - 24214.24 195986.63 - - -
Table # shows the summary of seismic analysis for the proposed four-storey dwelling
unit obtained from the given parameters based on NSCP 2015. The calculation shows the
summation of total dead load, calculated weight, shear force and moment in different floor
levels.