0% found this document useful (0 votes)
50 views1 page

22.02.2021 - CB - Floor Plan-Wd 05-Second Floor (Terrace) Layout

The document appears to be a technical drawing containing various labels, measurements, and geometric shapes. Key details include labels for different levels and areas identified by letters and numbers. Dimensions are provided in unspecified units of measurement between different points. Lines and shapes are used to demarcate different sections or components across multiple levels.

Uploaded by

Pratik Haripara
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
50 views1 page

22.02.2021 - CB - Floor Plan-Wd 05-Second Floor (Terrace) Layout

The document appears to be a technical drawing containing various labels, measurements, and geometric shapes. Key details include labels for different levels and areas identified by letters and numbers. Dimensions are provided in unspecified units of measurement between different points. Lines and shapes are used to demarcate different sections or components across multiple levels.

Uploaded by

Pratik Haripara
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Y0 G 1 F E D C 2 B A Y

16085

14035

12195

9705

7185

6195

4945

1915

0000
16315

2050 1840 2490 2520 990 1250 3030 1915


230
1200 6590

X 0000 0000 X
1430

1430
1 1430 1430 1
11890

C C
TERRACE
4200

4200
3970
U.F. LVL + 8020 MM
F.F. LVL + 8170 MM

2V
01 170

100
7800

2 5630 5630 2
12415

2D

230
1200 1200 6360
01
1430

1430
2290 2010 2800
STORE 230 CABIN 230
2630

2170

2170

2170

2630
1970
U.F. LVL + 8020 MM U.F. LVL + 8020 MM
3 7060 F.F. LVL + 8270 MM F.F. LVL + 8270 MM
STAIRCASE 170 X 110 GROOVE 7060 3
AS / DETAIL
3830

3830
EXPOSED R.C.C
970

970
230
1050 3990

4 8030 8030 4
230
2D

100
170
1430

1430
01

1200

1200
230
2900 8990
4100 3280 4050

5 9460 9460 5

TERRACE
2030

2030
1950

U.F. LVL + 8020 MM


B F.F. LVL + 8170 MM
B
170

EXPOSED
R.C.C.
6 11490 11490 6

24215
230

A A
4500

4500
RAILING
AS / DETAIL

C SECTIONS
ALL SIDE

4050

7 15990 15990 7
2030

2030
8 18020 18020 8
11800

6080

6080

X0 24100 24100 X0
2750

2050 1840 2490 2520 990 1250 3030 1915

10555 5760
16085

14035

12195

9705

7185

6195

4945

1915

0000

Y0 G 1 F E D C 2 B A Y

NOTE LEGENDS REV. REMARKS DATE MR. CHANDRAKANT BHAI RESIDENCE.


1. DIMENSIONS ARE IN MILLIMETER. R0 ---- ----
2. ALL MEASUREMENTS ARE FROM UNFINISHED SURFACE TO UNFINISHED BEAM DEPTH 600 MM (BEAM BOTTOM + 2700 MM) AT AHMEDABAD
SURFACE.
3. ALL DIMENSIONS ARE TO BE READ AND NOT TO BE MEASURED.
4. DRIP MOULD IS TO BE PROVIDED AT ALL EXTERNAL WINDOW LINTELS. SLAB THICKNESS 150 MM (SLAB BOTTOM + 3150 LVL)
5. A NICHE FOR RAIN WATER PIPES TO BE PROVIDED DURING WALL
CONSTRUCTION, AT POSITIONS INDICATED IN DRAWINGS.
6. CHICKEN MESH TO BE PROVIDED AT EVERY JUNCTION OF BRICK AND
EXPOSED SLAB WORKING LAYOUT
CONCRETE,TO BE PLASTERED.
7. RAIN WATER DRAIN PIPES THROUGH BEAMS AND CURBING TO BE INSTALLED SECOND FLOOR (TERRACE) WORKING
WHILE CASTING AS PER THE POSITIONS SHOWN IN DRAWING.(LEVEL TO BE
DECIDED ON SITE WITH REFERENCE TO AVAILABLE FLOOR GRADIENT.)
SLAB THICKNESS 125 MM (SLAB BOTTOM + 3175 LVL)
8. ALL DOORS & WINDOWS LINTEL ARE AT LVL.**** MM UNLESS OTHERWISE
REFERENCE EXECUTION
SPECIFIED.
9. IN CASE OF ANY DISCREPANCY BET'N ARCHITECTURAL DRGS. AND OTHER
230 MM THK MASONRY PURPOSE FOR. EXTRA COPY -
DRGS.,DISCREPANCY SHOULD BE BROUGHT TO THE NOTICE OF THE
ARCHITECT BEFORE COMMENCEMENT OF THE WORK.
120 MM THK MASONRY CODE P-1030 1111,Binori B square 02,Iscon
10. IN CASE OF ANY AMBIGUITIES ON SITE,THE ARCHITECT SHOULD BE INFORMED.
11. IT IS MUST TO INFORM AND TO HAVE PRIOR PERMISSION OF ARCHITECT
DRG. NO. WD-05 ambali road, Ahmedabad. INDIA
BEFORE MAKING ANY CHANGES ON SITE.
12.
13.
REFER THE LATEST REVISED DRAWING.
DIMENSIONS OF STRUCTURAL STEEL SECTION. AND JUNCTION DETAILS TO BE
E-MAIL:[email protected]
SCALE 1:100
14.
APPROVED FROM STRUCTURAL ENGINEER BEFORE EXECUTION.
BEFORE COMMENCING THE WORK IT IS MUST TO OBTAIN PRIOR PERMISSION
(M) +91 7574 832 648
FROM AUDA OR MUNICIPAL CORPORATION. DRG. BY. ---------- www.adityapaelarchitects.com
15. SOIL TESTING TO BE CARRIED OUT BEFORE COMMENCEMENT OF THE
FOUNDATION.
16. FOUNDATION & U.G.W.T DETAILS TO BE APPROVED FROM STRUCTURAL CHECKED ADITYA
ENGINEER .
17. IT IS MUST FOR RESPECTIVE SITE ENGINEER TO CHECK AND CO-RELATE THE
STRUCTURAL DRAWINGS WITH ARCHITECTURAL DRAWINGS. DATE 22.02.2021 ADITYA PATEL ARCHITECTS