0% found this document useful (0 votes)
137 views

Weight Transmitter Weight Transmitter: Description

The TLS weight transmitter is a device suitable for mounting on a DIN rail or junction box that measures weight transmitted from up to 8 load cells. It displays the weight on a 6-digit LED display and outputs the data through an analog output or RS485 serial port. It can be configured using free PC software and performs functions like tare settings, peak hold, and filtering of weight readings.

Uploaded by

phat nguyen minh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
137 views

Weight Transmitter Weight Transmitter: Description

The TLS weight transmitter is a device suitable for mounting on a DIN rail or junction box that measures weight transmitted from up to 8 load cells. It displays the weight on a 6-digit LED display and outputs the data through an analog output or RS485 serial port. It can be configured using free PC software and performs functions like tare settings, peak hold, and filtering of weight readings.

Uploaded by

phat nguyen minh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

TLS

WEIGHT TRANSMITTER

Instrument
Manager

EURO

170,00

DESCRIPTION MAIN FUNCTIONS

 Weight transmitter suitable for back panel mounting on Omega/DIN  Connections to:
rail or junction box (on request). - PLC via analog output;
 Dimensions: 123x92x50 mm. - PC/PLC via RS485 (up to 99 instruments with line repeaters, up
 6-digit semi-alphanumeric red LED display (8 mm height). to 32 without line repeaters);
 6 signalling LED. - remote display via RS485;
 4-key keyboard. - up to 8 load cells in parallel by junction box.
 The instrument can be configured and managed using the free  Digital filter to reduce the effects of weight oscillation.
“Instrument Manager” PC software, which you can download from  Theoretical calibration (via keyboard) and real calibration (with sample
www.laumas.com. weights and the possibility of weight linearization up to 8 points).
 Tare weight zero setting.
 Automatic zero setting at power-on.
INPUTS/OUTPUTS AND COMMUNICATION  Gross weight zero tracking.
 Semi-automatic tare (net/gross weight) and preset tare.
 RS485 serial port for communication via protocols ModBus RTU,  Semi-automatic zero.
ASCII Laumas or continuous one way transmission.  Displaying of the maximum weight value reached (peak).
 Current or voltage 16 bit optoisolated analog output.  Direct connection between RS485 and RS232 without converter.
 2 optorelay outputs controlled by the setpoint values or via protocols.  Hysteresis and setpoint value setting.
 2 optoisolated PNP digital inputs: status reading via serial
communication protocols.
 4 load cell dedicated inputs.

CERTIFICATIONS

UL Recognized component - Complies with the United States and Canada standards

Complies with the Eurasian Custom Union standards


Re v. 0. 0

LAUMAS Elettronica srl • Phone: (+39) 0521 683124 • Fax (+39) 0521 681091 ISO 9001
UFFICIO VENDITE ITALIA: [email protected] • EXPORT SALES DEPARTMENT: [email protected] ISO 14001 www.laumas.com
TLS
WEIGHT TRANSMITTER

TECHNICAL FEATURES

Power supply and consumption 12÷24 VDC ±10%; 5 W


Number of load cells • Load cells supply up to 8 (350 Ω) - 4/6 wires • 5 VDC/120 mA

Linearity • Analog output linearity <0.01% full scale • <0.01% full scale

Thermal drift • Analog output thermal drift <0.0005% full scale/°C • <0.003% full scale/°C

A/D Converter 24 bit (16000000 points) - 80 Hz

Divisions (with measurement range ±10 mV and sensitivity 2 mV/V) ±999999 • 0,01 μV/d
Measurement range ±19.5 mV
Usable load cells sensitivity ±3 mV/V
Conversions per second 80/s
Display range ±999999
Decimals • Display increments 0÷4 • x1 x2 x5 x10 x20 x50 x100
Digital filter • Readings per second 10 levels • 5÷80 Hz

Optorelay outputs 2 - max 24 VDC/60 mA

Optoisolated digital inputs 2 - 5÷24 VDC PNP


Serial ports RS485
Baud rate 2400, 4800, 9600, 19200, 38400, 115200 (bit/s)
16 bit = 65535 divisions. 0÷20 mA; 4÷20 mA (up to 300 Ω)
Optoisolated analog output
0÷10 V; 0÷5 V; ±10 V; ±5 V (min 10 kΩ)
Humidity (condensate free) 85%
Storage temperature -30 °C +80 °C
Working temperature -20 °C +60 °C

Optorelay outputs 2 - max 24 VDC/60 mA

Equipment to be powered by 12-24 VDC LPS or Class 2 power source

OPTIONS ON REQUEST

DESCRIPTION CODE EURO

IP67 polycarbonate box; dimensions: 170x140x95 mm


(four fixing holes Ø4 mm; centre distance: 152x122 mm)

- transparent cover CASTL 50,00


- transparent cover; 4+2 M16x1.5 cable glands - plugs CASTLPG9 70,00
- transparent cover; 4+2 PVC end-fittings for sheath CASTLGUA 70,00

- external keyboard CASTLTAST 100,00


- external keyboard; 4+2 M16x1.5 cable glands - plugs CASTLTASTPG9 120,00
- external keyboard; 4+2 PVC end-fittings for sheath CASTLTASTGUA 120,00

ATEX II 3GD (zone 2-22) version


CASTLTASTATEX 150,00
- external keyboard; 4+2 PG9 cable glands - plugs
Re v. 0. 0

The Company reser ves the right to make changes to the technical data, drawings and images without notice.

LAUMAS Elettronica srl • Phone: (+39) 0521 683124 • Fax (+39) 0521 681091 ISO 9001
UFFICIO VENDITE ITALIA: [email protected] • EXPORT SALES DEPARTMENT: [email protected] ISO 14001 www.laumas.com

You might also like