Weight Transmitter Weight Transmitter: Description
Weight Transmitter Weight Transmitter: Description
WEIGHT TRANSMITTER
Instrument
Manager
EURO
170,00
Weight transmitter suitable for back panel mounting on Omega/DIN Connections to:
rail or junction box (on request). - PLC via analog output;
Dimensions: 123x92x50 mm. - PC/PLC via RS485 (up to 99 instruments with line repeaters, up
6-digit semi-alphanumeric red LED display (8 mm height). to 32 without line repeaters);
6 signalling LED. - remote display via RS485;
4-key keyboard. - up to 8 load cells in parallel by junction box.
The instrument can be configured and managed using the free Digital filter to reduce the effects of weight oscillation.
“Instrument Manager” PC software, which you can download from Theoretical calibration (via keyboard) and real calibration (with sample
www.laumas.com. weights and the possibility of weight linearization up to 8 points).
Tare weight zero setting.
Automatic zero setting at power-on.
INPUTS/OUTPUTS AND COMMUNICATION Gross weight zero tracking.
Semi-automatic tare (net/gross weight) and preset tare.
RS485 serial port for communication via protocols ModBus RTU, Semi-automatic zero.
ASCII Laumas or continuous one way transmission. Displaying of the maximum weight value reached (peak).
Current or voltage 16 bit optoisolated analog output. Direct connection between RS485 and RS232 without converter.
2 optorelay outputs controlled by the setpoint values or via protocols. Hysteresis and setpoint value setting.
2 optoisolated PNP digital inputs: status reading via serial
communication protocols.
4 load cell dedicated inputs.
CERTIFICATIONS
UL Recognized component - Complies with the United States and Canada standards
LAUMAS Elettronica srl • Phone: (+39) 0521 683124 • Fax (+39) 0521 681091 ISO 9001
UFFICIO VENDITE ITALIA: [email protected] • EXPORT SALES DEPARTMENT: [email protected] ISO 14001 www.laumas.com
TLS
WEIGHT TRANSMITTER
TECHNICAL FEATURES
Linearity • Analog output linearity <0.01% full scale • <0.01% full scale
Thermal drift • Analog output thermal drift <0.0005% full scale/°C • <0.003% full scale/°C
Divisions (with measurement range ±10 mV and sensitivity 2 mV/V) ±999999 • 0,01 μV/d
Measurement range ±19.5 mV
Usable load cells sensitivity ±3 mV/V
Conversions per second 80/s
Display range ±999999
Decimals • Display increments 0÷4 • x1 x2 x5 x10 x20 x50 x100
Digital filter • Readings per second 10 levels • 5÷80 Hz
OPTIONS ON REQUEST
The Company reser ves the right to make changes to the technical data, drawings and images without notice.
LAUMAS Elettronica srl • Phone: (+39) 0521 683124 • Fax (+39) 0521 681091 ISO 9001
UFFICIO VENDITE ITALIA: [email protected] • EXPORT SALES DEPARTMENT: [email protected] ISO 14001 www.laumas.com