Spesifikasi Tiang Pancang by Pt. Tripalindo Persada
Spesifikasi Tiang Pancang by Pt. Tripalindo Persada
TRIPALINDD PERSADA
Pile Foundation
DESIGN READYMIX
Mutu Beton K-450 ( CEMENT MURNI)
3
Volume: 1 m
• PERHITUNGAN
Tegangan lzinTekan Seton = 0,33 x 450 kg/cm2 = 148,5 kg/cm2
zm an .. aJa
Tegangan l"T"kB. = 0.58 x 3.900 kg/cm2 = 2.262 kg/cm2
•
I PERHITUNGAN DAYA DUKUNG STRUKTUR TRI PILE
Type Segi Empat 25 x 25 cm
• DATA - DATA:
Panjang Sisi Tiang 25 cm
Mutu Beton K-450
- Mutu Baja Tulangan BJTS 420
- Ukuran dan Jumlah Baja Tulangan 4013 mm
Luas Baja Tulangan 5,307 cm2
- Luas Penampang Beton Netto 604.1 cm2
• PERHITUNGAN
Tegangan lzin Tekan Beton = 0,33 x 450 kglcm2 = 148.5 kg/cm2
Tegangan lzin Tarik Baja = 0, 58 x 3. 900 kg/cm2 - 2.262 kg/cm2
http://itphofpenrp01.indocement.co.id/itp/erp/prd_qlt_qa_report_0126_0147_reporting_prin... 4/9/2021
Test Certificate Page 2 of 2
This Laboratory is accredited by National Accreditation Body of Indonesia, KAN conforming SNI 19-17025-2000 with
registration no. LP-287-IDN. Prohibited to copy/duplicate and/or publish part of this report without permission from Quality
Assurance and Research Division Laboratory, PT Indocement Tunggal Prakarsa Tbk.
http://itphofpenrp01.indocement.co.id/itp/erp/prd_qlt_qa_report_0126_0147_reporting_prin... 4/9/2021
Scanned by CamScanner
Scanned by TapScanner