High Voltage: Regulated
High Voltage: Regulated
Power Supplies
High Voltage
REGULATED
Output Ranges:
0-1 kVdc to 0-30 kVdc
MODULAR AC-DC & DC-DC
• Shipped Within 6 Days
• Five Year Warranty
(internal encapsulated module - One Year)
RACK MOUNTING AC-DC
• Shipped Within 9 Days
• Five Year Warranty
(internal encapsulated module - One Year)
POW ER SU P P L IE S
REGULATED
Output ranges:
0- 1 kVdc to 0 - 30 kVdc
SPECIFICATIONS
Input Voltage: 105-125 VAC, 50-400 Hz, single phase. Stability: 0.05% over eight hours, after 30 minute
warmup.
Output Polarity: Positive output is standard. For negative
output, change first letter of model number from P to N. Temperature Coefficient: 200 PPM/°C = 0.02%/°C
(Typical).
Regulation (constant voltage operation):
Line: ±0.05% Ambient Operating Temperature: –10 to +60°C.
Load: ±0.05% No derating required.
Regulation (constant current operation): Storage Temperature: –20 to +85°C.
Line: ±0.1%
Humidity: Maximum of 90% relative, non-condensing.
Load: ±0.1% plus 50 µA.
Connections: 24˝ flying lead for high side of output and
Ripple: 0.05%, peak-to-peak.
5-way binding post for return (ground) are at the rear. AC
Output Controls: Voltage and current may be controlled input connections on separate terminal strip. All other
by means of two 20-turn front panel adjustments, or by connections on pluggable terminal block.
using remotely located 1000 ohm potentiometers.
Mounting: Threaded mounting holes permit mounting to
Output Programming: Output voltage and current may a chassis, cabinet wall or bracket, or they may be used
be programmed from 0 to full rating by means of control on a test bench or tabletop. To mount from the power
voltage inputs of 0 to +5.1 Vdc. supply side of the mounting surface, see accessory
Mounting Kit GB8 on page H3.
Voltage Monitor Terminal: Permits monitoring output
voltage, stepped down by ratio shown. Accuracy is 2% of OPTIONS
maximum rated output voltage. Terminal Strip Cover: Clips on AC input terminal strip.
Current Monitor Terminal: Permits monitoring output To order, add suffix “M” to model number and $5.00 to
current at mV/mA ratio shown. Accuracy is 2% of price.
maximum rated output current. Output Connector: Models with an output of 5000 volts
Inhibit Terminal: Grounding inhibits output. or less can be provided with an MHV connector (and
8 long detachable shielded output cable with mating MHV
Input Protection: “Soft start” circuit minimizes start-up connector installed on one end) instead of the flying lead.
power stresses. To order, add suffix letter “ T” to the model number and
Output Protection: Current regulation circuit protects $50.00 to price.
power supply from short circuits, overload, and arcing. 230 Volt Input: For operation on inputs of 210-250 VAC,
Efficiency: Greater than 70% at full load. 50-400 Hz, single phase. To order, add suffix “–230” to
model number and $40.00 to price. The “–230” option
Response Time: Less than 5 mS for 100 µA load step
requires two additional days.
change.
E1 Online Ordering and Instant Quotes for ALL Acopian power supplies at www.acopian.com
131 Loomis Street, Easton, PA 18045 • Phone: (610) 258-5441 • FAX: (610) 258-2842
011519
HIGH VOLTAGE AC – DC & DC – DC
AC-DC MODELS
Output Output Output Monitor Ratio Model
($)
Range
kVdc
Current
mA Voltage
Current
mV/mA Price ( Positive
Output )* Case
Size
0-1 30 1,000:1 100:1 725 P01HA30 HA349
0-1 60 1,000:1 10:1 835 P01HA60 HA359
0-1.5 20 1,000:1 100:1 725 P01.5HA20 HA349
0-1.5 40 1,000:1 100:1 835 P01.5HA40 HA359
0-2 15 1,000:1 100:1 725 P02HA15 HA349
0-2 30 1,000:1 100:1 835 P02HA30 HA359
0-2.5 12 1,000:1 100:1 725 P02.5HA12 HA349
0-2.5 24 1,000:1 100:1 835 P02.5HA24 HA359
0-3.5 8.5 1,000:1 100:1 725 P03.5HA8.5 HA349
0-3.5 17 1,000:1 100:1 835 P03.5HA17 HA359
0-5 6 10,000:1 100:1 795 P05HA6 HA349
0-5 12 10,000:1 100:1 905 P05HA12 HA359
0-7.5 4 10,000:1 100:1 795 P07.5HA4 HA349
0-7.5 8 10,000:1 100:1 905 P07.5HA8 HA359
0-10 3 10,000:1 1,000:1 795 P010HA3 HA349
0-10 6 10,000:1 100:1 905 P010HA6 HA359
0-12 2.5 10,000:1 1,000:1 795 P012HA2.5 HA349
0-12 5 10,000:1 100:1 905 P012HA5 HA359
0-15 2 10,000:1 1,000:1 835 P015HA2 HA349
0-15 4 10,000:1 100:1 945 P015HA4 HA359
0-18 1.6 10,000:1 1,000:1 835 P018HA1.6 HA349
0-18 3.2 10,000:1 1,000:1 945 P018HA3.2 HA359
0-20 1.5 10,000:1 1,000:1 945 P020HA1.5 HA349
0-20 3 10,000:1 1,000:1 1050 P020HA3 HA359
0-22 1.3 10,000:1 1,000:1 945 P022HA1.3 HA349
0-22 2.6 10,000:1 1,000:1 1050 P022HA2.6 HA359
0-25 1.2 10,000:1 1,000:1 1050 P025HA1.2 HA349 Case Approx.
0-25 2.4 10,000:1 1,000:1 1160 P025HA2.4 HA359 Size L W M V Q R Weight
0-30 1 10,000:1 1,000:1 1050 P030HA1 HA349 HA349 8.82 4.13 6.00 3.50 2.00 3.25 6 lb. 8 oz.
0-30 2 10,000:1 1,000:1 1160 P030HA2 HA359 HA359 9.33 5.13 7.00 4.50 2.78 4.25 10 lb.
* Positive output is standard. For negative output, change first letter
of model number from P to N.
Online Ordering and Instant Quotes for ALL Acopian power supplies at www.acopian.com
131 Loomis Street, Easton, PA 18045 • Phone: (610) 258-5441 • FAX: (610) 258-2842
E2
011519
High Voltage DC-DC
MODULAR
HIGH VOLTAGE AC – DC & DC – DC
REGULATED
Output ranges:
0- 1 kVdc to 0 - 30 kVdc
SPECIFICATIONS
Input Voltage: +21.6 to 32.0 Vdc. Efficiency: Greater than 70% at full load.
Output Polarity: Positive output is standard. For negative Response Time: Less than 5 mS for 100 µA load step
output, change first letter of model number from P to N. change.
Regulation (constant voltage operation): Stability: 0.05% over eight hours, after 30 minute
Line: ±0.05% warmup.
Load: ±0.05%
Temperature Coefficient: 200 PPM/°C = 0.02%/°C
Regulation (constant current operation): (Typical).
Line: ±0.1%
Load: ±0.1% plus 50 µA. Ambient Operating Temperature: –10 to +60°C.
No derating required.
Ripple: 0.05%, peak-to-peak.
Storage Temperature: –20 to +85°C.
Output Controls: Voltage and current may be controlled
by means of two 20-turn front panel adjustments, or by Humidity: Maximum of 90% relative, non-condensing.
using remotely located 1000 ohm potentiometers. Connections: 24˝ flying lead for high side of output
Output Programming: Output voltage and current may and 5-way binding post for return (ground). All other
be programmed from 0 to full rating by means of control connections on pluggable terminal block.
voltage inputs of 0 to +5.1 Vdc. Mounting: Threaded mounting holes permit mounting to
Voltage Monitor Terminal: Permits monitoring output a chassis, cabinet wall or bracket, or they may be used
voltage, stepped down by ratio shown. Accuracy is 2% of on a test bench or tabletop. To mount from the power
maximum rated output voltage. supply side of the mounting surface or for DIN rail
mounting, see accessory Mounting Kits on page H3.
Current Monitor Terminal: Permits monitoring output
current at mV/mA ratio shown. Accuracy is 2% of OPTIONS
maximum rated output current. Output Connector: Models with an output of 5000 volts
or less can be provided with an MHV connector (and 8
Inhibit Terminal: Grounding inhibits output. long detachable shielded output cable with mating MHV
Input Protection: “Soft start” circuit minimizes start-up connector installed on one end) instead of the flying lead.
power stresses. To order, add suffix letter “ T” to the model number and
$50.00 to price.
Output Protection: Current regulation circuit protects
power supply from short circuits, overload, and arcing.
E3 Online Ordering and Instant Quotes for ALL Acopian power supplies at www.acopian.com
131 Loomis Street, Easton, PA 18045 • Phone: (610) 258-5441 • FAX: (610) 258-2842
011519
HIGH VOLTAGE AC – DC & DC – DC
OPTIONAL OUTPUT CONNECTOR
Models with an output of 5000 volts or less can be
provided with an MHV connector (and 8 long detachable
output cable with mating MHV connector installed on one
end) instead of the flying lead. To order, add suffix letter
“T” to the model number and $50.00 to price.
DC-DC MODELS
Output Output Output Monitor Ratio Model
($)
Range
kVdc
Current
mA Voltage
Current
mV/mA Price (Positive
Output )* Case
Size
0-1 30 1,000:1 100:1 615 P01HD30 HD345
0-1 60 1,000:1 10:1 720 P01HD60 HD355
0-1.5 20 1,000:1 100:1 615 P01.5HD20 HD345
0-1.5 40 1,000:1 100:1 720 P01.5HD40 HD355
0-2 15 1,000:1 100:1 615 P02HD15 HD345
0-2 30 1,000:1 100:1 720 P02HD30 HD355
0-2.5 12 1,000:1 100:1 615 P02.5HD12 HD345
0-2.5 24 1,000:1 100:1 720 P02.5HD24 HD355
0-3.5 8.5 1,000:1 100:1 615 P03.5HD8.5 HD345
0-3.5 17 1,000:1 100:1 720 P03.5HD17 HD355
0-5 6 10,000:1 100:1 680 P05HD6 HD345
0-5 12 10,000:1 100:1 790 P05HD12 HD355
0-7.5 4 10,000:1 100:1 680 P07.5HD4 HD345
0-7.5 8 10,000:1 100:1 790 P07.5HD8 HD355
0-10 3 10,000:1 1,000:1 680 P010HD3 HD345
0-10 6 10,000:1 100:1 790 P010HD6 HD355
0-12 2.5 10,000:1 1,000:1 680 P012HD2.5 HD345
0-12 5 10,000:1 100:1 790 P012HD5 HD355
0-15 2 10,000:1 1,000:1 720 P015HD2 HD345
0-15 4 10,000:1 100:1 830 P015HD4 HD355
0-18 1.6 10,000:1 1,000:1 720 P018HD1.6 HD345
0-18 3.2 10,000:1 1,000:1 830 P018HD3.2 HD355
PLUGGABLE TERMINAL
0-20 1.5 10,000:1 1,000:1 830 P020HD1.5 HD345 BLOCK CONNECTIONS
0-20 3 10,000:1 1,000:1 940 P020HD3 HD355
0-22 1.3 10,000:1 1,000:1 830 P022HD1.3 HD345
0-22 2.6 10,000:1 1,000:1 940 P022HD2.6 HD355
0-25 1.2 10,000:1 1,000:1 940 P025HD1.2 HD345 Case Approx.
0-25 2.4 10,000:1 1,000:1 1045 P025HD2.4 HD355 Size W V R Weight
0-30 1 10,000:1 1,000:1 940 P030HD1 HD345
HD345 4.13 3.50 3.25 2 lb.
0-30 2 10,000:1 1,000:1 1045 P030HD2 HD355
HD355 5.13 4.50 4.25 2 lb. 12 oz.
* Positive output is standard. For negative output, change first letter
of model number from P to N.
Online Ordering and Instant Quotes for ALL Acopian power supplies at www.acopian.com
131 Loomis Street, Easton, PA 18045 • Phone: (610) 258-5441 • FAX: (610) 258-2842
E4
011519
High Voltage AC-DC
RACK MOUNTING
HIGH VOLTAGE AC – DC & DC – DC
REGULATED
Output ranges:
0- 1 kVdc to 0 - 30 kVdc
SPECIFICATIONS
Input Voltage: 105-125 VAC, 50-400 Hz, single phase. Output Programming: Output voltage and current may
be programmed from 0 to full rating by means of control
Input Current:
voltage inputs of 0 to +5.1 Vdc, ±2%.
30 watt output ratings: 0.6A
60 watt output ratings: 1.2A Output Protection: Current regulation circuit protects
power supply from short circuits, overload, and arcing.
Output Polarity: Positive output is standard. For negative
output, change first letter of model number from P to N. Response Time: Less than 5 mS for 100 µA load step
change.
Regulation (constant voltage operation): Stability: 0.05% over eight hours, after 30 minute
Line: ±0.05% warmup.
Load: ±0.05%
Temperature Coefficient: 200 PPM/°C = 0.02%/°C
Regulation (constant current operation): (Typical).
Line: ±0.1%
Ambient Operating Temperature: –10 to +60°C.
Load: ±0.1% plus 50 µA.
No derating required.
Ripple: 0.05%, peak-to-peak. Storage Temperature: –20 to +85°C.
Output Controls: Voltage and current may be controlled Humidity: Maximum of 90% relative, non-condensing.
by means of two 10-turn front panel adjustments with
Connections:
locking vernier dials. Control linearity is 1% of full rated Input, Control and Monitoring: Screw terminals.
output. Calibration accuracy is 1% of rated output Output: High voltage connector (Type varies with
plus 1% of setting. (Remotely located 1000 ohm model number). An 8 shielded output cable, with
potentiometers may alternately be used for output control.) mating connector installed, is provided.
Metering: Voltmeter and ammeter are standard. Accuracy OPTIONS
is 2% of full scale. Terminal Strip Cover: Clips on AC input terminal strip.
Voltage Monitor Terminal: Permits remote monitoring of To order, add suffix “M” to model number and $5.00 to
output voltage, stepped down by ratio shown. Accuracy is price.
2% of maximum rated output voltage. 230 Volt Input: All models can be alternately furnished for
operation on inputs of 210-250 VAC, 50-400 Hz,
Current Monitor Terminal: Permits remote monitoring of single phase. To order, add suffix “–230” to model number
output current, at mV/mA ratio shown. Accuracy is 2% of and add $40.00 to price. The “–230” option requires two
maximum rated output current. additional days.
Inhibit Terminal: Grounding inhibits output.
Input Protection: “Soft start” circuit minimizes start-up
power stresses.
E5 Online Ordering and Instant Quotes for ALL Acopian power supplies at www.acopian.com
131 Loomis Street, Easton, PA 18045 • Phone: (610) 258-5441 • FAX: (610) 258-2842
011519
HIGH VOLTAGE AC – DC & DC – DC
AC-DC MODELS
Output Output Output Monitor Ratio Model
($)
Range
kVdc
Current
mA Voltage
Current
mV/mA Price (Positive
Output )* Voltage Adjust Current Adjust
Online Ordering and Instant Quotes for ALL Acopian power supplies at www.acopian.com
131 Loomis Street, Easton, PA 18045 • Phone: (610) 258-5441 • FAX: (610) 258-2842
E6
011519
WALL MOUNTING KITS ...$10
These kits provide a way of mounting power supplies on a wall or panel when the other side of the .375
1.5
1.125
.125
mounting surface is inaccessible. Each kit consists of four aluminum brackets and four machine screws
for fastening them to the power supply, effectively adding mounting flanges to the power supply. .75
OTHER PRODUCTS & INFO
For ‘Gold Box’ and (modular) ‘High Voltage’ power supplies: .171 dia .375
*
LH35DIN Mounting Kit (Horizontal mounting)
Can be used on these case sizes: LM6A, LM8A, LM10A Locking
*
Screw
All DIN Kits for LM cases $20
NPH35DIN Mounting Kit (Horizontal mounting)
Can be used on these case sizes:
CN8H DN6A F6T N8H TN6T WN6A
GR35DIN LR35DIN NPV35DIN
CN8T DN6B F8T N8T TN8H WN6B
DN8 WN8
DN8A WN8A
WN8B
NPR35DIN Mounting Kit (Rear mounting)
Can be used on these case sizes:
CN8H F6T N8H TN6T
CN8T F8T N8T TN8H WLH35DIN WH35DIN NPR35DIN
H3 Online Ordering and Instant Quotes for ALL Acopian power supplies at www.acopian.com
131 Loomis Street, Easton, PA 18045 • Phone: (610) 258-5441 • FAX: (610) 258-2842
011519
ACOPIAN SELLS FACTORY DIRECT WORLDWIDE: We do not use representatives or distributors. Contact Acopian for technical information or a quote.
WARRANTY: Acopian power supplies are warranted to be free from defects in material and workmanship for a period of five years (encapsulated devices, for
one year) from date of original shipment. Acopian’s obligation under this warranty is limited to repairing any power supply returned to the factory Service
Department in Easton, PA or Melbourne, FL, and replacing any defective parts. Mini Encapsulated power supplies are not repairable. Authorization must be
obtained from Acopian before a power supply may be returned for repair. Units must be well packed when shipping to Acopian; the repair of any damage incurred
Online Ordering and Instant Quotes for ALL Acopian power supplies at www.acopian.com
131 Loomis Street, Easton, PA 18045 • Phone: (610) 258-5441 • FAX: (610) 258-2842
H8
011519