0% found this document useful (0 votes)
900 views

S7L1D-F4 Wdg.312 - Technical Data Sheet

This technical data sheet provides specifications for an industrial alternator including standards, quality assurance, excitation and voltage regulation systems, electrical data, time constants, resistances, saturation factors, mechanical data, efficiency curves, and motor starting curves.

Uploaded by

3efoo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
900 views

S7L1D-F4 Wdg.312 - Technical Data Sheet

This technical data sheet provides specifications for an industrial alternator including standards, quality assurance, excitation and voltage regulation systems, electrical data, time constants, resistances, saturation factors, mechanical data, efficiency curves, and motor starting curves.

Uploaded by

3efoo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

S7L1D-F4 Wdg.

312 - Technical Data Sheet


Standards
STAMFORD industrial alternators meet the requirements of the relevant parts of the IEC EN 60034 and the relevant
section of other international standards such as BS5000, VDE 0530, NEMA MG1-32, IEC34, CSA C22.2-100 and
AS1359. Other standards and certifications can be considered on request.

Quality Assurance

Alternators are manufactured using production procedures having a quality assurance level to BS EN ISO 9001.

Excitation and Voltage Regulators


Excitation System
AVR Type MX341 MX322 DECS150
Voltage Regulation ± 1% ± 0.5% ± 0.25% with 4% Engine Governing
AVR Power PMG PMG PMG

No Load Excitation Voltage (V) 15.4 - 14.7


No Load Excitation Current (A) 0.68 - 0.64
Full Load Excitation Voltage (V) 64
Full Load Excitation Current (A) 2.8
Exciter Time Constant (seconds) 0.125

Page 1 S7L1D-F4_Wdg.312_A062L871_Rev.B_22.08.2019
S7L1D-F4 Wdg.312

Electrical Data
Insulation System H
Stator Winding Double Layer Concentric
Winding Pitch 2/3
Winding Leads 6
Winding Number 312
Number of Poles 4
IP Rating IP23

RFI Suppression BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N.


Refer to factory for others
Waveform Distortion NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0%
Short Circuit Ratio 1/Xd
Steady State X/R Ratio 27.41
50 Hz 60 Hz
Telephone Interference THF<2% TIF<50
Cooling Air Flow 2.52 m³/sec 3.02 m³/sec
Voltage Star (V) 380 400 415 440 416 440 460 480
Voltage Parallel Star (V) - - - - - - - -
Voltage Delta (V) - - - - - - - -

kVA Base Rating (Class H) for


1845 1900 1900 1865 2070 2212 2256 2300
Reactance Values (kVA)

Saturated Values in Per Unit at Base Ratings and Voltages


Xd Dir. Axis Synchronous 2.75 2.56 2.38 2.08 3.09 2.96 2.76 2.58
X'd Dir. Axis Transient 0.20 0.19 0.18 0.15 0.23 0.22 0.20 0.19
X''d Dir. Axis Subtransient 0.15 0.14 0.13 0.11 0.16 0.16 0.15 0.14
Xq Quad. Axis Reactance 2.02 1.88 1.75 1.52 2.27 2.17 2.02 1.90
X''q Quad. Axis Subtransient 0.24 0.22 0.20 0.18 0.26 0.25 0.24 0.22
XL Stator Leakage Reactance 0.09 0.08 0.08 0.07 0.10 0.09 0.09 0.08
X2 Negative Sequence Reactance 0.17 0.16 0.15 0.13 0.20 0.19 0.17 0.16
X0 Zero Sequence Reactance 0.03 0.03 0.03 0.02 0.04 0.03 0.03 0.03
Unsaturated Values in Per Unit at Base Ratings and Voltages
Xd Dir. Axis Synchronous 3.31 3.07 2.85 2.49 3.71 3.55 3.31 3.10
X'd Dir. Axis Transient 0.24 0.22 0.20 0.18 0.26 0.25 0.24 0.22
X''d Dir. Axis Subtransient 0.17 0.16 0.15 0.13 0.19 0.18 0.17 0.16
Xq Quad. Axis Reactance 2.08 1.94 1.80 1.57 2.34 2.23 2.09 1.95
X''q Quad. Axis Subtransient 0.28 0.26 0.24 0.21 0.32 0.30 0.28 0.27
XL Stator Leakage Reactance 0.10 0.09 0.08 0.07 0.11 0.11 0.10 0.09
Xlr Rotor Leakage Reactance 0.21 0.20 0.19 0.16 0.24 0.23 0.22 0.20
X2 Negative Sequence Reactance 0.21 0.19 0.18 0.16 0.23 0.22 0.21 0.20
X0 Zero Sequence Reactance 0.04 0.04 0.03 0.03 0.04 0.04 0.04 0.04

Page 1 S7L1D-F4_Wdg.312_A062L871_Rev.B_22.08.2019
S7L1D-F4 Wdg.312

Time Constants (Seconds)


T’d Transient Time Const. 0.15
T’’d Sub-Transient Time Const. 0.0165
T’do O.C. Field Time Const. 4.29
Ta Armature Time Const. 0.0276
T’’q Sub-Transient Time Const. 0.0102
0
Resistances in Ohms (Ω) at 22 C
Stator Winding Resistance (Ra),
0.0009
per phase for series connected
Rotor Winding Resistance (Rf) 1.95
Exciter Stator Winding Resistance 22.3
Exciter Rotor Winding Resistance per
0.065
phase
PMG Phase Resistance (Rpmg) per
1.91
phase
Positive Sequence Resistance (R1) 0.0106
Negative Sequence Resistance (R2) 0.0122
Zero Sequence Resistance (R0) 0.0106
Saturation Factors 400V 480V
SG1.0 0.281 0.304
SG1.2 1.308 1.184
Mechanical Data
Shaft and Keys
All alternator rotors are dynamically balanced to better than BS6861: Part 1 Grade 2.5 for
minimum vibration in operation. Two bearing generators are balanced with a half key.

1 Bearing 2 Bearing
SAE Adaptor SAE 0, 00 SAE 0, 00
Moment of Inertia 40.98 kgm² 40.08 kgm²
Weight Wound Stator 1518kg 1518kg
Weight Wound Rotor 1353kg 1300kg
Weight Complete Alternator 3350kg 3264kg
Shipping weight in a Crate 3399kg 3313kg
Packing Crate Size 200 x 105 x 155 (cm) 200 x 105 x 155 (cm)
Maximum Over Speed 2250 RPM for two minutes
Bearing Drive End - BALL. 6228
Bearing Non-Drive End BALL. 6319 BALL. 6319

Page 1 S7L1D-F4_Wdg.312_A062L871_Rev.B_22.08.2019
S7L1D-F4 Wdg.312

THREE PHASE EFFICIENCY CURVES

50Hz 60Hz

Page 1 S7L1D-F4_Wdg.312_A062L871_Rev.B_22.08.2019
S7L1D-F4 Wdg.312

Locked Rotor Motor Starting Curves - Separately Excited


50Hz

60Hz

Transient Voltage Dip Scaling Factor Transient Voltage Rise Scaling Factor
PF Factor
< 0.5 1 For voltage rise multiply voltage dip by 1.25
0.5 0.97
0.6 0.93
0.7 0.9
0.8 0.85
0.9 0.83

Page 1 S7L1D-F4_Wdg.312_A062L871_Rev.B_22.08.2019
S7L1D-F4 Wdg.312

Three-phase Short Circuit Decrement Curve - Separately Excited

50Hz

Sustained Short Circuit = 7046 Amps


60Hz

Sustained Short Circuit = 8246 Amps


Note 1 Note 3
The following multiplication factors should be The following multiplication factor should be used to convert the
used to adjust the values from curve between values calculated in accordance with NOTE 1 to those
time 0.001 seconds and the minimum current applicable to the various types of short circuit :
point in respect of nominal operating voltage :

50Hz 60Hz 3-phase 2-phase L-L 1-phase L-N


Voltage Factor Voltage Factor Instantaneous x 1.00 x 0.87 x 1.30
380V X 1.00 416V X 1.00 Minimum x 1.00 x 1.80 x 3.20
400V X 1.05 440V X 1.06 Sustained x 1.00 x 1.50 x 2.50
415V X 1.09 460V X 1.10 Max. sustained duration 10 sec. 5 sec. 2 sec.
440V X 1.16 480V X 1.15 All other times are unchanged
Note 4
The sustained current value is constant irrespective of Curves are drawn for Star connected machines under no-load
voltage level excitation at rated speeds. For other connection (where
Note 2 applicable) the following multipliers should be applied to
The sustained current values are for MX341 current values as shown :
AVR. For MX322 and Digital AVR 1.2 factor to Parallel Star = Curve current value X 2
be applied to the sustained short circuit Series Delta = Curve current value X 1.732

Page 1 S7L1D-F4_Wdg.312_A062L871_Rev.B_22.08.2019
S7L1D-F4 Wdg.312

Typical Alternator Operating Charts


400V/50Hz

480V/60Hz

Page 1 S7L1D-F4_Wdg.312_A062L871_Rev.B_22.08.2019
S7L1D-F4 Wdg.312

RATINGS AT 0.8 POWER FACTOR

Class - Temp Rise Standby - 163/27°C Standby - 150/40°C Cont. H - 125/40°C Cont. F - 105/40°C
Star (V) 380 400 415 440 380 400 415 440 380 400 415 440 380 400 415 440
50 Parallel Star (V) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
Delta (V) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
Hz
kVA 1975 2035 2035 1995 1920 1980 1980 1940 1845 1900 1900 1865 1715 1770 1770 1735
kW 1580 1628 1628 1596 1536 1584 1584 1552 1476 1520 1520 1492 1372 1416 1416 1388
Efficiency (%) 95.6 95.6 95.7 95.9 95.6 95.7 95.8 95.9 95.7 95.8 95.9 96.0 95.9 95.9 96.0 96.1
kW Input 1653 1702 1701 1665 1606 1655 1654 1618 1542 1587 1585 1554 1431 1476 1475 1444

Star (V) 416 440 460 480 416 440 460 480 416 440 460 480 416 440 460 480
60 Parallel Star (V) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

Hz Delta (V) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
kVA 2219 2369 2419 2469 2156 2300 2350 2400 2070 2212 2256 2300 1937 2056 2100 2144
kW 1775 1895 1935 1975 1725 1840 1880 1920 1656 1770 1805 1840 1550 1645 1680 1715
Efficiency (%) 95.6 95.6 95.7 95.8 95.7 95.7 95.8 95.8 95.7 95.8 95.8 95.9 95.8 95.9 96.0 96.0
kW Input 1857 1982 2022 2063 1803 1923 1963 2004 1730 1848 1883 1919 1617 1715 1751 1787

De-Rates
All values tabulated above are subject to the following reductions:
- 5% when air inlet filters are fitted
- 3% for every 500 meters by which the operating altitude exceeds 1000 meters above mean sea level
- 3% for every 5°C by which the operational ambient temperature exceeds 40°C @ Class H temperature rise
(please refer to applications for ambient temperature de-rates at other temperature rise classes)
- For any other operating conditions impacting the cooling circuit please refer to applications
Note: Requirement for operating in an ambient exceeding 60°C and altitude exceeding 4000 meters (for <690V) or
1500 meters (for >690V) must be referred to applications.

Dimensional and Torsional Drawing


For dimensional and torsional information please refer to the alternator General Arrangement and rotor drawings
available on our website (http://stamford-avk.com/)

Note: Continuous development of our products means that the information contained in our data sheets
can change without notice, and specifications should always be confirmed with Cummins Generator
Technologies prior to purchase.

Page 1 S7L1D-F4_Wdg.312_A062L871_Rev.B_22.08.2019
Follow us @stamfordavk

Cummins Generator Technologies

View our videos at youtube.com/stamfordavk

news.stamford-avk.com

For Applications Support:


[email protected]

For Customer Service:


[email protected]

For General Enquiries:


[email protected]

Copyright 2016. Cummins Generator Technologies Ltd. All rights reserved.


Cummins and the Cummins logo are registered trade marks of Cummins Inc.
STAMFORD is a registered trade mark of Cummins Generator Technologies Ltd.

Page 1 S7L1D-F4_Wdg.312_A062L871_Rev.B_22.08.2019

You might also like