Communication Unit 560CMR02 Communication Unit 560CMR02: RTU560 Product Line RTU560 Product Line

Uploaded by

Hammad8
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views4 pages

Communication Unit 560CMR02 Communication Unit 560CMR02: RTU560 Product Line RTU560 Product Line

Uploaded by

Hammad8
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Remote Terminal Units - Data sheet

Communication Unit 560CMR02


RTU560 product line

Communication module of the RTU560 with 32 bit


CPU
• 6x serial communication interface (RS-232 or
RS-485) for remote communication
• 2x Ethernet interface (10/100BaseT)
• 1x USB port
• 1x serial peripheral bus
• battery buffered real time clock

Application
The 560CMR02 communication unit is one of the CMU E1 E2 CP1, CP2, CP3, CP4,
CP5, CP6
10/100 MB LAN 10/100 MB LAN
modules of the RTU560 product line. RS232C or RS485

The essential tasks are:


• Managing and controlling of the I/O modules via the Ethernet Ethernet
UART
interface to the serial I/O bus. Controller Controller
• Reading Process events from the input modules.
• Send commands to the output modules.
• Communicating with control systems and local HMI
systems via the serial interface (RS232) and the Processor bus
Ethernet 10/100BaseT interfaces.
• Communication with Sub-RTU’s, IED’s or multimeter
devices via the interfaces (RS485) and the Ethernet Serial line MPU RAM/Flash
interfaces. interface ARM cortex A8 Memory

• Managing the time base for the RTU560 product line


station and synchronizing the I/O modules.
• Handling the dialog between RTU560 product line and
Web-Browser via the LAN interfaces. SPB I/O bus USB
Within the RTU560 racks the board occupies two slots.
Figure 1: Block diagram 560CMR02
The communication unit is able to handle Ethernet- and
UART-character based communication protocols.
Characteristics
The unit has a battery buffered real time clock (RTC).
On the applied ARM cortex A8 controller AM3352 a real-
The unit is available in 2 versions: time operating system is implemented. The 560CMR02
• R0001: with standard cyber security functions is responsible for the interface management, the event
• R0002: with security chip for advanced cyber security handling, the time base and the internal data base. The
functions controller acts as master for the SPB I/O bus (serial
peripheral bus). RTU560 synchronizes itself to the time
references supplied by 560RTC0x. The time information
of the 560RTC0x is provided to the 560CMR02 on the
backplane of the sub-rack.

System relevant configuration files are stored in the non-


volatile flash memory card (removable SD-card™) in order
to guarantee a valid system configuration after Power on
Reset (PoR).

A battery buffered RTC is used to keep an exact time


during power off state.

The communication unit provides the following interfaces:


• Communication Port 1 ... 6 (CP1 ... CP6): serial
interfaces according RS232C or RS485 with RJ45
connectors. CP1 and CP2 can be configured
independant as SPB I/O bus interface to the front.
• Ethernet interface 1 and 2 (E1 & E2): 10/100BaseT
with RJ45 connector.
• USB 2.0 device interface for diagnosis and
maintenance purposes.
• The SPB I/O bus is directly connected to the
backplane connector.
Technical data Current consumption for power supplied via RTU560
In addition to the RTU500 series general technical data, backplane
the following applies: 5 V DC 600 mA
24 V DC 4 mA
Main Processing Unit MPU
CPU ARM cortex A8, AM3352 @
Signaling by LEDs
800 MHz
ERR (red) ON: RTU in error state
RAM 128 MByte
Boot Flash 8 MByte Flashing: RTU in warning
state
SD card For more details see
Connector SD card slot (push push) RTU500 series Function
Description
Type SD 2.0, class 2
RUN (green) Communication module in
Capacity 4 GByte
operation
T Transmit data on serial
Real time clock RTC (Backup) communication ports CP
Battery Lithium 3 V DC, CR2032 R Receive data on serial
Time resolution 1 sec, 1ms with timesync communication ports CP
Battery lifetime > 10 years S Ethernet communication
speed:
Free running ± 50 ppm
ON: 100 Mbit/s

Serial interfaces 1, 2, 3, 4, 5 and 6 OFF: 10 Mbit/s


Connector RJ45 L Link up (ON) / Activity
Type RS232C or RS485 (Flashing) on Ethernet
interface E
RS232C:
Bit rate 200 bit/s - 38.4 kbit/s
Signal lines GND E2/102 Mechanical layout
TxD D1/103 Dimensions 160 mm x 100 mm, 3HE
euro card format
RxD D2/104 8R (40 mm) front panel
RTS S2/105 Housing type Printed circuit board
Mounting for mounting in RTU560
CTS M2/106
racks
DTR S1.2/108 Weight 0.19 kg
DCD M5/109
Level typical: ± 6V
Connection type
RS485:
RTU560 backplane 48 pole type F DIN 41612
Bit rate 200 bit/s - 38.4 kbit/s connector
Level typical: ± 6V

Immunity test
Ethernet interface E1 and E2
Electrostatic discharge 8 kV air / 6 kV contact (level
Connector RJ45
IEC 61000-4-2 3)
Type IEEE 802.3, 10/100BaseT
Performance criteria A

USB interface Radiated Radio-Frequency 10 V/m (level 3)


Electromagnetic Field
Connector micro USB Type AB IEC 61000-4-3 Performance criteria A
(female)
Electrical Fast Transient / 4 kV (level X)
Type USB 2.0 device, low, full Burst
and high speed (max. 480 IEC 61000-4-4 Performance criteria A
MBit/s)
Surge 2 kV (level 3)
Cable type to PC USB Type A <-> micro USB IEC 61000-4-5
Type B Performance criteria A
Conducted Disturbances, 10 V (level 3)
induced by Radio-
Frequency Fields Performance criteria A
IEC 61000-4-6
Immunity test
Damped oscillatory wave 2.5 / 1 kV (level 3)
IEC 61000-4-18
Performance criteria A

Environmental conditions - climatic


Operating temperature -25 °C ... 70 °C
EN 60068-2-14
Start up -40 °C
EN 60068-2-1
Max. operating temperature, +85 °C
max. 96h
EN 60068-2-2
Relative humidity 5 ... 95 %
EN 60068-2-30 (non condensing)

Ordering information
560CMR02 R0001 1KGT036300R0001

560CMR02 R0002 1KGT036300R0002

ABB Power Grids Germany AG We reserve the right to make technical We reserve all rights in this document and in the ABB is a registered trademark of ABB
changes or modify the contents of this subject matter and illustrations contained therein. Asea Brown Boveri Ltd. Manufactured by/
1KGT 150 937 V006 1

P.O. Box 10 03 51 document without prior notice. With regard Any reproduction, disclosure to third parties or for a Hitachi Power Grids company.
68128 Mannheim, Germany to purchase orders, the agreed particulars utilization of its contents – in whole or in parts – is
shall prevail. Hitachi ABB Power Grids does forbidden without prior written consent of Hitachi
not accept any responsibility whatsoever ABB Power Grids.
for potential errors or possible lack of © 2020 Hitachi Power Grids
hitachiabb-powergrids.com/rtu information in this document. All rights reserved