KRISHNEEL DUTT
ID: 2018001114
DECLARATION
I, Krishneel Dutt declare that the Design of roofing structures (resilient timber bolt connection) is my
own piece of work. The whole report writing and details are my own work.
SIGNATURE:
BACKGROUND
Timber connections are now being designed considering both ductile and brittle failure modes using
the detailed method in the proposed new connection chapter yet to be codified.
For the truss connection shown in Figure 1, design the specified joints, determining the number of
bolts, sizes, spacings and design also the steel plates.
DELIVERABLES:
Submit your design report showing sketches with all dimensions and grades of materials to be used
so that a draft person can make a final drawing.
Submit your calculations in an Appendix.
DESIGN JOINTS:
Joint 2, 3, and 4. These are all steel-wood-steel joints. Assume a size & grade for the steel plates.
The plates will be cut from one piece (no welding calcs needed). State any required assumption and
verify its validity.
BASE INFORMATION
DESIGN JOINT 2
STEEL PLATE
MATERIAL PROPERTIES OF GRADE 300 STEEL PLATE
BOLTS
Bolts of grade 4.6 fuf = 400 Mpa
SECTION PROPERTIES
Diameter of bolt d= 20 mm
Number of bolts n= 6
Bolt spacing a1 90 mm 4d 80 OK
Row spacing a2 70 mm 3d 60 OK
Loaded end distance a3t 110 mm 5d 100 OK
Unloaded edge distance a4c 70 mm 3d 60 OK
DETAILED DESIGN
DUCTILE MODE
JOINT RESISTANCE
1. YIELDING RESISTANCE (N a,y,u)
Mean density of LVL 11 p= 570 kg/m3
Depth of timber section t2 = 180 mm
Load combination k1 = 0.8
Tensile Strength fuf = 440 Mpa
Thickness of Plate t1 = 8 mm
Diameter of Bolt d= 20 mm
STEEL
Fi = ᵩs 3.2 fuf ᵩs = 0.9
F1 (Side member, steel plate) F1 = 1267.2
LVL 11 Øy = 0.8
F2 = Øy (0.075p(1-0.0037d))K1 k1 = 1
F2 = 31.6692
Ƀ = F2/F1 0.024991
FAILURE MODE A
Na,y,u = f 1dt1
Na,y,u = 202.752 Kn
FAILURE MODE B
Na,y,u = (F2dt2)/2
Na,y,u = 57.00456 KN
FAILURE MODE C
Na,y,u =
F1dt1= 202752
2+Ƀ = 2.024991
2*Ƀ 0.049983 Nax = 27.701 kN Nax = 27.701 LH Term
1+Ƀ 1.024991 Nax = 6.92525 Nax = 75.4 Axial resistance
4*Ƀ 0.099966 Na,y,u = 34.63 Nax = 31.4 Bearing resistance
F1dt12 1622016
FAILURE MODE D
Na,y,u = 28.06269
FINALLY
Na,y,u = Na,y,u n ns Na,y,u = 28.06269
Na,y,u = 336.7523 Kn number of bolts= n= 6
number of shear planes
ns= 2
N*= 320 kN
Reduction factor for wood фw = 0.7 AGT net = Critical area between outer rows
1 row, 2 shear planes Rs1 = 437.4 AGTnet = a2-(d+2)t2
1 row, 2 shear planes Rs2 = 437.4 AGT net = Critical
21240areamm2
between outer rows
Tensile stress parallel to grain ft = 30
Diameter of bolt d= 20 GT = 0.5(RS1+RS2) + 1.25ft AGT
Depth of timber section t2 = 180 GT= 1233.9 Kn
Row spacing a2 = 140
Load combination k1 = 1 No gt = фw GT k1 k12
dry timber k12 = 1 No gt = 863.73 kN
DESIGN OF BOLTS
Capacity of 1 BOLT
SO ф Vf = 106.9376 > Vf* 26.66667 kN OK
DESIGN OF STEEL PLATE
ф Nt = ф (Ag.fy) ф Nt = ф (0.85kt.An.fup)
ф Nt = 460.8 KN ф Nt = 420.0768 KN
LVL 11 TIMBER
Breadth of the timber section b= 360
depth of timber section t2 = 180
MATERIAL PROPERTIES
Tensile stress parallel to grain ft = 30 Mpa
Tensile stress perpendicular to grain ftp = 1.45 Mpa
shear stress fs = 6 Mpa
Fracture parameter Cfp 16 Nmm
Modulus of Elasticity E = 11000 Mpa
Modulus of Rigidity G= 550 Mpa
Mean Density of LVL 11 P= 570 kg/m3
Load combination K1 = 1
STEEL PLATE
MATERIAL PROPERTIES OF GRADE 300 STEEL PLATE
BOLTS
Bolts of grade 4.6 fuf = 400 Mpa
SECTION PROPERTIES
Diameter of bolt d= 24 mm
Number of bolts n= 6
Bolt spacing a1 100 mm 4d 96 OK
Row spacing a2 80 mm 3d 72 OK
Loaded end distance a3t 130 mm 5d 120 OK
Unloaded edge distance a4c 80 mm 3d 72 OK
DETAILED DESIGN
DUCTILE MODE
JOINT RESISTANCE
1. YIELDING RESISTANCE (N a,y,u)
Mean density of LVL 11 p= 570 kg/m3
Depth of timber section t2 = 180 mm
Load combination k1 = 1
Tensile Strength fuf = 440 Mpa
Thickness of Plate t1 = 10 mm
Diameter of Bolt d= 24 mm
STEEL
Fi = ᵩs 3.2 fuf ᵩs = 0.9
F1 (Side member, steel plate) F1 = 1267.2
LVL 11 Øy = 0.8
F2 = Øy (0.075p(1-0.0037d))K1 k1 = 1
F2 = 31.16304
Ƀ = F2/F1 0.024592
FAILURE MODE A
Na,y,u = f 1dt1
Na,y,u = 304.128 Kn
FAILURE MODE B
Na,y,u = (F2dt2)/2
Na,y,u = 67.31217 KN
FAILURE MODE C
Na,y,u =
F1dt1= 304128
2+Ƀ = 2.024592
2*Ƀ 0.049184 Nax = 39.81 kN Nax = 39.81 LH Term
1+Ƀ 1.024592 Nax = 9.9525 Nax = 108.6 Axial resistance
4*Ƀ 0.098368 Na,y,u = 34.63 Nax = 45 Bearing resistance
F1dt12 3041280
FAILURE MODE D
Na,y,u = 38.6582
FINALLY
Na,y,u = Na,y,u n ns Na,y,u = 38.6582
Na,y,u = 463.8984 Kn number of bolts= n= 6
number of shear planes
ns= 2
N*= 405 kN
Reduction factor for wood фw = 0.7 AGT net = Critical area between outer rows
1 row, 2 shear planes Rs1 = 486 AGTnet = a2-(d+2)t2
1 row, 2 shear planes Rs2 = 486 AGT net = Critical
9720areamm2
between outer rows
Tensile stress parallel to grain ft = 30
Diameter of bolt d= 24 GT = 0.5(RS1+RS2) + 1.25ft AGT
Depth of timber section t2 = 180 GT= 850.5 Kn
Row spacing a2 = 80
Load combination k1 = 1 No gt = фw GT k1 k12
dry timber k12 = 1 No gt = 595.35 kN
DESIGN OF BOLTS
Capacity of 1 BOLT
ф Vf = 153.9584 > Vf* 33.75 kN OK
DESIGN OF STEEL PLATE
ф Nt = ф (Ag.fy) ф Nt = ф (0.85kt.An.fup)
ф Nt = 345.6 KN ф Nt = 228.888 KN
STEEL PLATE
MATERIAL PROPERTIES OF GRADE 300 STEEL PLATE
BOLTS
Bolts of grade 4.6 fuf = 400 Mpa
SECTION PROPERTIES
Diameter of bolt d= 12 mm
Number of bolts n= 6
Bolt spacing a1 50 mm 4d 48 OK
Row spacing a2 40 mm 3d 36 OK
Loaded end distance a3t 70 mm 5d 60 OK
Unloaded edge distance a4c 40 mm 3d 36 OK
BRITTLE MODE
Loaded end distance a3t = 70 mm
1. ROW SHEAR RESISTANCE Row spacing a1 = 50 mm
Shear stress fy = 6 Mpa
depth of timber section t2 = 180 mm
no. of column of bolts nfi = 3
acri = 50
no. of rows of bolts nr = 2
wood as an internal member KLS = 1
RSI= Design Shear Capacity along shear planes
Reduction factor for wood фw = 0.7 AGT net = Critical area between outer rows
1 row, 2 shear planes Rs1 = 243 AGTnet = a2-(d+2)t2
1 row, 2 shear planes Rs2 = 243 AGT net = Critical
4680areamm2
between outer rows
Tensile stress parallel to grain ft = 45
Diameter of bolt d= 12 GT = 0.5(RS1+RS2) + 1.25ft AGT
Depth of timber section t2 = 180 GT= 506.25 Kn
Row spacing a2 = 40
Load combination k1 = 1 No gt = фw GT k1 k12
dry timber k12 = 1 No gt = 354.375 kN
NET TENSION
N o,t = ф Nt K1 K12
984.96 kN
DESIGN OF BOLTS
Capacity of 1 BOLT
SO ф Vf = 37.53728 > Vf* 10.25 kN OK
JOINT IN COMPRESSION
THUS: Ns = Kf.An.fy
Ns = 124.8891 KN
фNs = 112.4002 kN
N* < фNs
N* 61.5 KN < фNs 112.4002 KN OK