0% found this document useful (0 votes)
102 views2 pages

5 300 HP - 3 PHASE, 50/60 HZ

The document summarizes a 300 HP, 3 phase AC to DC converter packaged drive system. It consists of a Pacemaster 12 power module, DC contactor, fuses, and control transformer. It provides fully regenerative motor control in all four quadrants up to 300 HP. Standard features include NEMA power code C compliance, isolated feedback, electronic overload protection, and remote fault indication.

Uploaded by

tu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
102 views2 pages

5 300 HP - 3 PHASE, 50/60 HZ

The document summarizes a 300 HP, 3 phase AC to DC converter packaged drive system. It consists of a Pacemaster 12 power module, DC contactor, fuses, and control transformer. It provides fully regenerative motor control in all four quadrants up to 300 HP. Standard features include NEMA power code C compliance, isolated feedback, electronic overload protection, and remote fault indication.

Uploaded by

tu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

5 - 300 HP .

3 PHASE, 50/60 Hz

STANDARD FEATURES
. PACEMASTER 12 POWER MODULE - Fully regenerative,
AC to DC converter including:
.. NEMA power codeC .. Phase sequence insensitivity

.. Reconnectable operation
Horsepower calibration ..Isolated feedback
Direct line operation

.. Heatsink thermostat
Current surge protection .Electronic motor overload
LED fau" i(ldicators

..Vo"age transient protection.


Field current regulator
Separate potentiometer
..
Remote fau" indication
Fau" relay output
Many User selectable
board functions
For a complete Pacemaster 12 power module description
refer to data sheet DS-PM12.

GENERAL DESCRIPTION . DC ARMATURE CONTACTOR designed to break full load


The Pacemaster 12 packaged DC drive IS a three phase, full current
wave, AC to DC converter for precise control of motor speed . HIGH SPEED CURRENT LIMITING SCR TYPE FUSES for
and torque. The drive package consists of a panel mounted both the incoming AC line and DC motor armature.
Pacemaster 12 power module, DC loop contactor, current
limiting fuses for both the AC line and DC motor armature and . FUSED 115 VAC CONTROL TRANSFORMER
115VACcontrol transformer.
The Pacemaster 12 packaged drive is an armature reversing,
. DEADBACK 12 GAUGE MOUNTING PANEL

fully regenerative unit providing control in all four quadrants. . WIRING OF ALL COMPONENTS TO TERMINAL STRIPS
Available in six (6) basic packaged drives through 300 HP, it for easy customer interface.
has been developed for powering high speed automatic
. HORSEPOWER CALIBRATION - Jumper selectable horse-
machinery where controlled torque, starting, stopping, direction
and speed changing are critical factors. Its fast response to power calibration to any standard rating within a packaged
machine requirements helps to provide improved productivity. drive range.
The Pacemaster 12 is a high performance unit with
conservatively rated power components. Each packaged drive
. COMPLETE OFFERING OF PACKAGED DRIVE OPTIONS

is selectable for operation by either 230 or 460 volts AC. In


addition, horsepower, armature voltage feedback, scaling and
PACKAGED DRIVE ACCESSORIES
field current are jumper selectable to match the requirements
. WOUND FIELD DC MOTORS - 5-300 HP constant torque
of the DC motor.
Pretested logic semi-conductors, high frequency and transient and constant horsepower integral frame DC motors supplied
voltage protection, adjustable current limit and solid state motor with a variety of enclosures and options to meet the application
overload protection assist in providing reliability of the system
and protection of the driven equipment.
Pacemaster 12 packaged drives are designed and manufac-
. requirements.
ISOLATION TRANSFORMERS - 7.5-330 KVA drive isolation
transformers, three phase, delta primary, wye secondary, in
tured to comply with applicable standards established by the a NEMA 1 enclosure to provide drive isolation and/or AC
National Electrical Code and NEMA for industrial motor and line voltage matching.
control equipment. Standard Pacemaster 12 power modules
. OPERATOR CONTROLS - Standard and custom operator
are UL Recognized. These Pacemaster 12 packaged drives
can be supplied as UL Listed. Consult your CMC representative control stations, operating devices and meters to provide
for further information. control and visual indication of the driven equipment.
AVAILABLE OPTIONS
..AC Line Inductors .. AC Line Circuit Breaker
.. Regenerate to a Stop
DynamicBraking .. FusedBlowerMotorStarter
Speedand Load Meters
.. Isolated
Reversingby Relays
PresetSpeedBoard
Integral Test Meter (increases size of A module to a B)

.. 240 Voltage/ProcessFollower
VDC Field Supply .
. NEMA 1 Enclosure
NEMA 12 Ventilated Enclosure

. High CurrentField Supply(25 amps DC)


FieldWeakeningfor ConstantHorsepowerOperation
.
.
Interlocked Through-the-Door Circuit Breaker Handle
Enclosure Mounted Operator Controls

SPECIFICATIONS

RATINGS PERFORMANCE CHARACTERISTICS


HorsepowerRange .... 5-150 HP or 230 VAC Speed Range:
5-300 HP or 460 VAC with Armature Voltage Feedback. . . 30:1
AC Line InputVoltage. . . . . . 230or460V with Tach Feedback ............. 100:1
AC Line Frequency. . . . . . . 50or60Hz
3 Phase Speed Regulation:
with Armature Voltage Feedback. . . 2%
DC OutputVoltages
230 VAC Supply:
Armature ......... " ~ 'e'A
'.~';';l: 0-240VDC
with Tach Feedback. . . . . . . . . . . .
Minimum Load
0.1101%

Field. .......... .. ~ ~ 150VDC forstableoperation ............. 5%


460 VAC Supply: " i;.~ Efficiency
Armature ......... O-SOOVDC (Rated Speed/Rated Load) ....... ...96%
Field. . . . . . . . . . . . , 300VDC Displacement Power Factor. . . . . . . . . ...88%
ServiceFactor ........... 1.0
Duty ................... Continuous (Typical)
Maximum Load Capacity. . . . . . . . . 150% for 1 minute
Power Conversion. . . . . . . . . .. NEMA Power Code C
ADJUSTMENTS
Maximum Field Amperes (DC! Size A & B-5A. Size C-10A Accel/Decel............ . . . . . . . 2-20 sec (Linear Time)

Size D-25A CurrentLimit........... . . . . . . . . 0-150% (of Full Load)


Maximum Speed. . . .. . . . 70-110% (of Base Motor Speed}
OPERATING CONDITIONS IR (Load! Compensation. . . . 0-10% (of Rated DC Voltage)
Line Voltage Variation. ... ..... + 10% to -5% of Nominal
Line Frequency Variation. . ... ................ :t: 3 Hz
Speed Adjustment
Ambient Temperature. . . . 0" to 55" C (320 to 1310 F) with External 1000 Ohm.
Relative Humidity. .. . . .. 5 to 95% (without condensation) 2WaIlPot.......... , 010100%
Altitude . t03300Fl(1000M) (of Raled Speed)

TYPICAL CONTROLLER RATINGS OUTLINE DIMENSIONS


DIMENSIONS IN INCHES
230 VAC INPUT 460 VAC INPUT
3 PHASE 3 PHASE
Field
Arm Max Arm
Motor Input DC DC Input DC
Horse AC Amps Amps AC Amps
Power Amps (240V) (150V) Amps (500V)

5 16 20 5 8 10
75 25 29 5 12 14
10 32 38 5 16 18
15 47 55 5 22 27
20 61 72 5 30 34
25 77 89 5 36 43
30 89 106 5 43 51
40 114 140 10 55 67
50 145 173 10 70 83
60 170 206 10 80 99
75 211 255 10 105 123
100 284 341 10 135 164
125 349 425 25 170 205
150 414 508 25 200 246
200 270 330
250 332 405
300 398 480

DATA SUBJECT TO CHANGE WITHOUT NOTICE.


REPRESENTED BY:

INDUSTRIAL PRODUCTS DIVISION


ClevelandMotionControls
.
7550 Hub Parkway. Cleveland,OH 44125-5794
Phone216-524-8800 Fax 216-642-2121
An ~ c.....-
c 1997 Cleveland Motion Controls. All Rights R_rved. Printed in U.S.A. 2M698CR IPD-DSPP12