0% found this document useful (0 votes)
27 views

Task 3 - Second Data

The document analyzes the performance of an off-grid PV system with a 450 Wp solar panel and 550 Wh battery in a location at 25.285 latitude and 51.193 longitude. It provides monthly estimates of average daily energy production and energy not captured, as well as the percentage of days the battery was fully charged or empty. It also shows the probability distribution of the battery's state of charge at the end of each day.

Uploaded by

Nascent Onr
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
27 views

Task 3 - Second Data

The document analyzes the performance of an off-grid PV system with a 450 Wp solar panel and 550 Wh battery in a location at 25.285 latitude and 51.193 longitude. It provides monthly estimates of average daily energy production and energy not captured, as well as the percentage of days the battery was fully charged or empty. It also shows the probability distribution of the battery's state of charge at the end of each day.

Uploaded by

Nascent Onr
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Performance of off-grid PV systems

PVGIS-5 estimates of solar electricity generation


Provided inputs Outline of horizon at chosen location:
Latitude/Longitude: 25.285, 51.193 Slope angle: 35 °
Horizon: Calculated Azimuth angle 0°
Database used: PVGIS-SARAH Simulation outputs
PV installed: 450 Wp Percentage days with full battery: 99.52 %
Battery capacity: 550 Wh Percentage days with empty battery: 0.5 %
Cutoff limit: 40 % Average energy not captured: 1642.61 Wh
Consumption per day: 390 Wh Average energy missing: 45.77 Wh

Power production estimate for off-grid PV:

Monthly average performance


Month E_d E_l f_f f_e
January 389.0 1428.3 98.7 1.6
February 389.9 1611.1 99.4 0.6
March 390.0 1668.4 99.7 0.3
Battery performance for off-grid PV system: April 390.0 1617.3 99.7 0.3
May 390.3 1650.3 100.0 0.0
June 390.1 1654.7 100.0 0.0
July 390.0 1631.7 100.0 0.0
August 389.7 1722.3 100.0 0.0
September 389.9 1854.3 100.0 0.0
October 389.7 1825.4 100.0 0.0
November 389.7 1516.3 99.2 1.1
December 388.5 1439.5 97.6 2.1
E_d: Average energy production per day [Wh/day].
E_l: Average energy not captured per day [Wh/day].
f_f: percentage of days when battery became full [%].
f_e: percentage of days when battery became empty [%].

Probability of battery charge state at the end of the day: Cs Cb


40-46 0.0
46-52 1.0
52-58 11.0
58-64 15.0
64-70 11.0
70-76 5.0
76-82 4.0
82-88 5.0
88-94 4.0
94-100 43.0

Cs: Charge state at the end of each day [%].


Cb: percentage of days with this charge state [%].

The European Commission maintains this website to enhance public access to information about its initiatives and European
Union policies in general. Our goal is to keep this information timely and accurate. If errors are brought to our attention, we will PVGIS ©European Union, 2001-2021.
try to correct them.
Reproduction is authorised, provided the source is acknowledged,
However, the Commission accepts no responsibility or liability whatsoever with regard to the information on this site.
save where otherwise stated.
This information is:

i) of a general nature only and is not intended to address the specific circumstances of any particular individual or entity,
Report generated on 2021/04/06
ii) not necessarily comprehensive, complete, accurate or up to date,

iii) sometimes linked to external sites over which the Commission services have no control and for which the Commission
assumes no responsibility,

iv) not professional or legal advice (if you need specific advice, you should always consult a suitably qualified professional).

You might also like