C and 90% Relative Humidity Manufactured by Any One of The Manufacturers As Specified in Annexure "A" or Equivalent

1. The document provides specifications for electrical and allied works including the provision, installation, and commissioning of mechanical lifts. 2. Technical details of the lifts are given including machine type, safety features, speed, motor, operation type, travel distance, car dimensions and materials, door types, controls, and indicators. 3. One passenger lift with a 1000kg capacity is required to serve 7 floors from the ground floor to the roof. Technical compliance with relevant EN and IEC standards is specified.

Uploaded by

Abdul Hayee
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
838 views3 pages

C and 90% Relative Humidity Manufactured by Any One of The Manufacturers As Specified in Annexure "A" or Equivalent

1. The document provides specifications for electrical and allied works including the provision, installation, and commissioning of mechanical lifts. 2. Technical details of the lifts are given including machine type, safety features, speed, motor, operation type, travel distance, car dimensions and materials, door types, controls, and indicators. 3. One passenger lift with a 1000kg capacity is required to serve 7 floors from the ground floor to the roof. Technical compliance with relevant EN and IEC standards is specified.

Uploaded by

Abdul Hayee
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Electrical BOQ

ELECTRICAL & ALLIED WORKS

S. No. Description Qty Unit Rate Amount


1.0 LIFTS
Providng, Installation, complete commisioning and
testing of mechnical Lift at designated location of
appropriate cabin size (as mentioned below); suitable for
operation at 50°C and 90% relative humidity
manufactured by any one of the manufacturers as
specified in annexure “A” or equivalent.

Assembled in accordance with their provided drawings /


manuals and consisting of painted welded steel bed
plate; frame work to accommodate the with all imported
material of desired specification including the cost of ERD
"emergency rescue device" and fire rated doors (with 02
hour minimum capacity to reduntand the fire).

It includes the connection of necessary control & power


cables with suitable arragements duly approved by the
electro-mechanical consultant in all respect. complete
with electronic safeties to given regulation to BS EN 81
will apply to all new installations; Safety requirements for
passenger and goods electric lifts to safeguard
passengers and maintenance personnel against injury.

Technical Specification of Lifts


1 Type: Machine Room Type / Traction Type
2 Equipped with following:
1-Emergency Landing Device (ELD)
2- Emergency Rescue Device (ERD)
3 Speed: 1.0 meter/second (m/s)
4 Machine & Drive system: Synchronous permanent
magnet with two independent brake system and Variable
voltage variable frequency (VVVF) drive.
5 Motor Starts per Hour: 240 Starts per hour.
6 Operation: Full collective duplex group.
7 Travel: As per architectural drawings
8 Hoistway Size: As per manufacturer and structure
engineer recommendationan
9 Pit Depth: As per architectural drawings.
10 Overhead Height: As per architectural drawings.
11 Location of Machine Room Rooftop as per architectural
drawings
12 Elevator car ceiling,lighting and ventilation :
13 Satin Stainless steel from manufacturer’s
standard range. Ventilation by means of
electric blower.
14 Car walls: Etched finish stainless steel in pattern selected
to consultant’s choice from manufacturer’s standard
range of designs.
Page 1 of 3
Electrical BOQ

ELECTRICAL & ALLIED WORKS

S. No. Description Qty Unit Rate Amount


15 Car door: Etched finish stainless steel in pattern selected
to consultant’s choice from manufacturer’s standard
range of designs
16 Car Cabin Flooring: 20 mm recess will have to be
provide in the cabin platform to take local flooring
(local flooring by main contractor to Consultants
choice).
17 Car sill: Extruded hard Aluminum
18 Indicators: Horizontal on Ground Floor, Vertical on Other
Floor combined unit comprising of digital led dot-display
hall position indicator with direction arrows and hall call
buttons which will illuminate on registration of a call.
Face plate will be in satin stainless steel from
manufacturer’s standard range.
19 Landing Doors: On All Floors in Etched finish stainless
steel in pattern selected to consultant’s choice from
manufacturer’s standard range of designs.

20 Architraves: On All Floors Lintel and splayed door


frame to cover full wall thickness in hairline finished
stainless steel.
21 Entrance landing sills: Extruded hard aluminum.
22 Door Operation: AC / DC motor with electronic control .

23 Type of hoistway, doors at all floors: Power operated


2 panel automatic sliding center opening. Doors shall be
UK 2 Hrs fire rated.
24 Door Opening size: As per manufacturer
recommandation.
25 Control: Group control.
26 Cabin Indicators: Built – in digital led dot – display car
position indicator with direction arrows will have to be
incorporated on top of the car operating panel to
facilitate better view of the position of car comfortably
even during crowded condition.
27 Car operating panel: Car operating panel with call
buttons of micro stroke click type, which will illuminate
on registration of a call will be located on the side wall of
the Car. Faceplate will be in satin finished stainless steel.

28 ELD Device & Protections: Automatic Emergency


Landing Device per EN standard 81-1,2 & relevant
standards.

a Passenger Lift : 1000 KG


Estimated Shaft Dimension : 2134mm x 1753mm
1 Nos -
GF+1F to 5F+Roof
7 Steps / Floors

Page 2 of 3
Electrical BOQ

ELECTRICAL & ALLIED WORKS

S. No. Description Qty Unit Rate Amount


Important Note:
1 The Bidder shall provide the complete Technical
Literature for the system offered.
2-Contractor / supplier to enure the integeration of entire
system with
3-Contractor / manufacturer to duly ensure the size of
elevators, well size & cabin size from approved layouts
and from site under the presence of engr.incharge prior
to the procurement.

4-Above item shall be complete in all respects complying


with revelent EN / IEC standards.
5-Items required for the completion of the job shall
Make: Canny China/Fujizy China/ OTIS China/ Mitsubishi
China/ Hyundi China