0% found this document useful (0 votes)
90 views

Roof Sheeting Technical Data Sheet

This document provides specifications for composite panel systems that can be used for roof and wall cladding. It includes tables with allowable uniform load values for different panel thicknesses and spans. Panel thicknesses range from 50mm to 100mm. Higher thicknesses result in higher moment values and allowable load capacities. Load capacities decrease with increased panel spans. The document also specifies the materials, coatings, and mechanical properties that can be used for the aluminum and galvanized steel skin panels.

Uploaded by

Syed Abuthahir
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
90 views

Roof Sheeting Technical Data Sheet

This document provides specifications for composite panel systems that can be used for roof and wall cladding. It includes tables with allowable uniform load values for different panel thicknesses and spans. Panel thicknesses range from 50mm to 100mm. Higher thicknesses result in higher moment values and allowable load capacities. Load capacities decrease with increased panel spans. The document also specifies the materials, coatings, and mechanical properties that can be used for the aluminum and galvanized steel skin panels.

Uploaded by

Syed Abuthahir
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

C L A D D I N G & R O O F I N G S Y S T E M C L A D D I N G & R O O F I N G S Y S T E M

TSP 45 / 250 - Composite Panels (Roof & Wall Cladding)


(t Panel Core I x (cm4) z top z bottom Moment Moment
Thickness for 1m width for 1m width cm3 for 1m width cm3 kN m Top kN m Bottom
(mm)
50 35 9 28 1.08 3.28
75 85 18 30 2.09 3.52
100 174 31 40 3.56 4.62
based on 0.7 mm external and 0.5 mm internal Aluminium skin

Assumes bond with insulation ensures that lateral sliding of sheets does not occur & insulation does not have significant
compression

(t) Allowable Uniform Loads kN/m2


Panel
1.0 m 1.5 m 2.0 m 2.5 m 3.0 m 3.5 m 4.0 m 4.5 m 5.0 m
Thick-
ness
S D S D S D S D S D S D S D S D S D
(mm)
50 8.63 13.52 3.84 4.00 2.16 1.69 1.38 0.86 0.96 0.50 0.70 0.32 0.54 0.21 0.43 0.15 0.35 0.11
75 16.71 32.71 7.42 9.69 4.18 4.09 2.67 2.09 1.86 1.21 1.36 0.76 1.04 0.51 0.82 0.36 0.67 0.26
100 28.45 66.86 12.65 19.81 7.11 8.36 4.55 4.28 3.16 2.48 2.32 1.56 1.78 1.04 1.41 0.73 1.14 0.53
2
fy Al 170 N/mm permisible span - deflection ratio = 100

(t) Panel I x (cm4) z top z bottom Moment Moment


Thickness for 1m width for 1m width cm3 for 1m width cm3 kN m Top kN m Bottom
Applications (mm)
Roof and wall Panel 50 27 7 25 1.17 4.26

Specification 75 71 14 29 2.37 4.93

• Aluminium profiled sheet is 0.5 mm. up to 0.9 mm. thick Alloy A3105 - H16 100 148 24 39 4.05 6.63
Temper from tension leveled coils - different Alloy can be supplied on Based on 0.5 mm external and 0.5 mm internal GI skin
request.
• GI & Alu Zinc coated steel profile sheets 0.5 to 0.9 mm thick as per ASTM Assumes bond with insulation ensures that lateral sliding of sheets does not occur & insulation does not have significant
A 656 for GI & ASTM A 792 for Alu Zinc - Different grades Can be supplied compression
on request
• Painting is baked regular modified enamel polyester, with 5 micron
(t) Allowable Uniform Loads kN/m2
primer and 20 micron coat on the weathering side and 5/7 micron primer
Panel
on the reverse - PVDF, Silicon, Modified Polyester, Platisol & ARS coating 1.0 m 1.5 m 2.0 m 2.5 m 3.0 m 3.5 m 4.0 m 4.5 m 5.0 m
Thick-
on request is applicable.
ness
S D S D S D S D S D S D S D S D S D
(mm)
50 9.39 30.48 4.17 9.03 2.35 3.81 1.50 1.95 1.04 1.13 0.77 0.71 0.59 0.48 0.46 0.33 0.38 0.24
75 18.94 79.51 8.42 23.56 4.74 9.94 3.03 5.09 2.10 2.94 1.55 1.85 1.18 1.24 0.94 0.87 0.76 0.64
100 32.37 166.60 14.39 49.36 8.09 20.82 5.18 10.66 3.60 6.17 2.64 3.89 2.02 2.60 1.60 1.83 1.29 1.33
Permisible span-deflection ratio = 100

fy GI 250 N/mm2

t = Thickness S = Strength D = Deflection

You might also like