Eave Detail @Lean-To Gable End Closure Detail

The document provides details for roof sheeting and flashing for a building including: - 210 panel Lokseam run with standard lapping at 80mm from steel line - Double standard metal downspouts located at specified distances along the roof - 08 panel Pebroof run with standard lapping and 500mm lap at last panel - Gable trim and end flashing trim specified at locations along the roof

Uploaded by

LUUVANDONG48XF
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
210 views1 page

Eave Detail @Lean-To Gable End Closure Detail

The document provides details for roof sheeting and flashing for a building including: - 210 panel Lokseam run with standard lapping at 80mm from steel line - Double standard metal downspouts located at specified distances along the roof - 08 panel Pebroof run with standard lapping and 500mm lap at last panel - Gable trim and end flashing trim specified at locations along the roof

Uploaded by

LUUVANDONG48XF
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

98570 (OUT TO OUT OF STEEL LINE / BLOCKWALL LINE)

210 PANEL LOKSEAM RUN W/STD LAP


START/END OF SHEETING
80MM FROM STEEL LINE
DOUBLE STD METAL DOWNSPOUTS
CANOPY CANOPY CANOPY CANOPY
DOWNSPOUTS 500 6385 6600 6600 6100 7600 5900 5900 7400 5500 7260 6140 6100 7600 6100 6385 500
LOCATION
EAVE TRIM & EAVE GUTTER
53335 (OUT TO OUT OF STEEL LINE / BRICKWALL LINE)

SLOPE 10%

SLOPE 10%

SLOPE 10%
GABLE TRIM

GABLE TRIM
DETAIL ROOF PANEL INSULATION FOR LOK SEAM

CONCRETE
"TRANFORMER YARD"
(BY OTHER)
(LEAN-TO AREA)
SEALANT

START/END OF SHEETING
SC-5001

00MM FROM STEEL LINE


(BY PEB)

08 PANEL PEBROOF RUN W/STD LAP


END FLASHING TRIM @LEAN-TO
FL-0818A FL+12040 @500
SC-7001

LAP 500MM @LAST PANEL


GABLE TRIM SC-0001@250 @500

& EAVE GUTTER


CL-0007

90
7500 (O/O)
EAVETRIM
CL-0004
10%
SLOP 10%

GABLE TRIM

Bend Ridge At Site


END FLASHING TRIM (WITH BRICKWALL)
5000 INSULATION 250
CONCRETE AREA (O/O) CL-0403
BLOCKWALL
(BY OTHER)
PEB
STEEL BUILDINGS

CL-0001 BEND PANEL AT END TR-0027@500


BLOCKWALL SC-7001@500 LOK SEAM PANEL 0.5MM THK; COLOR: TBE
PEBROOF PANEL 250 SC-1001@500
SC-5001@500 END FLASHING TRIM DETAIL @MAIN ROOF
FL-0818A

SC-0001@250

2xSC-2002@500 SC-0001@125 PURLIN

SC-1001@500

SC-1002@500
O PE
SL
SC-4001@50
FL-0801
SC-1001@500
EAVE PURLIN
ROOF PANEL FL-0401
TR-0006
FL-0802A
TR-0003A
BLOCK SIDEWALL FL-0402
TR-0012A

EAVE DETAIL @LEAN-TO GABLE END CLOSURE DETAIL


250
SC-1001@500 CONCRETE
80 80 2xSC:1002
TR-0003A TR:0005@470 SC:1001@80 (BY OTHER)
LOCK SEAM PANEL SC:1001@500
CL:0003 PEBROOF PANEL
FL-0401A FL-0401A SC:1001@470 SEALANT
0-100 SC:2002@1500
TR:0025 0% SC-5001
GABLE TRIM
(2)M12x30 MSB SC:0001@500 SLOP 1 FL-0043A (BY PEB)
@500
TR-0012A FL:0001
SC-2002 @ HI-RIB FL+3960
FL-0401
@ 250

40
SC:0001@150 TR:0007
90 ROOF PANEL
SC:1001@500 PURLIN END
TR-0003 START PE -1000
START OF END OF SC:4001@500 SC:1002
SHEETING SHEETING
EAVE TRIM
FL:0802 TR:0006 GABLE ANGLE
FL-0402 EAVE GUTTER 150
SC:0001@500 TR:0003 STEEL RAFTER SC-1003@ LOW-RIB
SC-0001@300 SC-1002 PURLIN FL:0801B
CL:0002 SC:1002@1500
BEND END PANEL AT SITE
EAVE PURLIN
CL-0006 WALL WALL PANEL

GABLE DETAIL @MAIN ROOF EAVE DETAIL @MAIN ROOF GABLE DETAIL @LEAN-TO END FLASHING TRIM DETAIL @LEAN-TO B