0% found this document useful (1 vote)
2K views

EN6000B6

The document describes an EN6000B6 temperature and process scanner that features 8 or 16 input channels that can accept various sensor types including thermocouples, RTDs, voltages, currents, and resistances. It has alarm relays, communication options, accurate measurements, and flexible configuration options. Power supply options include 85-265VAC or 20-32VDC. Accessories include weatherproof enclosures for external alarm cards and relay modules.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (1 vote)
2K views

EN6000B6

The document describes an EN6000B6 temperature and process scanner that features 8 or 16 input channels that can accept various sensor types including thermocouples, RTDs, voltages, currents, and resistances. It has alarm relays, communication options, accurate measurements, and flexible configuration options. Power supply options include 85-265VAC or 20-32VDC. Accessories include weatherproof enclosures for external alarm cards and relay modules.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

TEMPERATURE / PROCESS SCANNER

EN6000B6

FEATURES
• Intelligent multi channel data acquisition/ display
• 8 / 16 Channels - Universal Input (TC/ RTD/ mA/ mV/ V/ Ω)
• Every channel is independently programmable for input, range & alarms
• Input channels are isolated for all inputs except RTD/ Ω
• Common/ Independent Low & High Alarm relays for each channel
• 24VDC Power supply for 2 wire transmitters – on 3 channels
• High accuracy (14 bit resolution), µP based
• Self Diagnosis function: Input fail safe operation
• Communication (RS485/ RS232)/ MODBUS/ Printer port
• EMI /ESD protection; CE approved

TECHNICAL SPECIFICATIONS
INPUT
• Thermocouple : S, B, T, R, K, E, J, N
• RTD : Pt100, Cu50, Cu100
• Voltage : (-)20 - 20mV DC, (-)100 -100mV DC, 0 -100mV DC, 0 - 500mV
0-1VDC, 0-5V DC, 1-5V DC, 0-10V DC
• Current Signals : 0-10mA, 4-20mA, 0-20mA
• Square root extraction : 0-5V DC, 1-5V DC, 0-10mA, 4-20mA
• Resistance Signals : 0-100 Ω, 30-350 Ω

MEASURING ACCURACY : ± 0.2% FS ±1 Digit, typical

RESOLUTION : T/C: 1°C (0.1°C Upto 999.9°C) / RTD: 0.1°C

DISPLAY Process Value - Type : 4 digit, 7 segment LED, Red


Size : 14 mm (0.56”) in 96 x 96 mm; 9 mm (0.35”) in 48 x 96 or 96 x 48
Channel No. Type : 4 digit, 7 segment LED, Green
Size : 9 mm (0.35”)

CHANNEL DISPLAY TIME : Programmable from 1 to 100 seconds

OUTPUT (Optional)
Linear Retransmission output : 4-20mA (14bit resolution), isolated, 0-20mA (option)
Accuracy : ± 0.3% FS, typical
Alarm output : None/ Common One/ Two (High / Low) Alarm Relay/s (built-in) /
Independent High & Low Alarm Relays per channel (in external
wall mount enclosure);Option: SSR drive Voltage in place of Relay
Alarm relay rating : Common alarm: 1 Amp/ 250 VAC, resistive load; 3/10 A (Optional)
Independent alarm: 3 Amp/ 250 VAC, resistive load
TRANSMITTER POWER SUPPLY : 24V DC/ 30 mA, isolated for 2 wire type; upto 3 nos. (Optional)

COMMUNICATION (Optional) : RS485 - ASCII Protocol/ MODBUS / Serial Printer Port

SIZE
Bezel (W x H), mm : 96 x 96 or 48 x 96 or 96 x 48
Panel cut out (W x H), mm : 90.5 x90.5 44.5 x 90.5 90.5 x 44.5
MODEL SELECTION
EN6000B6 - A B C D E F
Item Specification Code Details

1 8 Channel Scanner (No Alarms)


2 8 Channel Scanner (Common Alarms), 1 Am p*/ 250 VAC, res is tive load
(With upto 2 Nos Alarms outputs - Select from C & D below)
3 8 Channel Scanner (Independent Alarms)
(With 16 Open Collector Alarms through a External DIN Rail Mounted card)
For Weather Proof Enclosure for Card and Relay Outputs refer Accessories
offered below
A Model
4 16 Channel Scanner (No Alarms)
5 16 Channel Scanner (Common Alarms), 1 Am p*/ 250 VAC, res is tive load
(With upto 2 Nos Alarms outputs - Select from C & D below)
6 16 Channel Scanner (Independent Alarms)
(With 32 Open Collector Alarms through a external DIN Rail Mounted card)
For Weather Proof Enclosure for Card and Relay Outputs refer Accessories
offered below
* Models with Common Alarms are also available with Relay contact rating 3 or 10 Amp
3 96 x 96mm
Dimensions
B (W x H) mm
4 48 X 96 (Available in 8 Channel Models only)
5 96 X 48 (Available in 8 Channel Models only)

0 None
Alarm 1 1 Relay Alarm Output 1A/250 V AC (Resistive Load)*
(For Scanner with
C common Alarms 2 Solid State Relay (SSR)
only) 3 Isolated 24 V/ 30 mA, 2 wire transmitter Power Supply
9 Special

0 None
Alarm 2** 1 Relay Alarm Output 1A/250 V AC (Resistive Load)*
(For Scanner with
D common Alarms 2 Solid State Relay (SSR)
3 Isolated 24 V/ 30 mA, 2 wire transmitter Power Supply
only)
9 Special
**If ordered, Alarm 2 should be same type as Alarm 1, i.e. If Alarm 1 is Relay, Alarm 2 should also be
Relay or if instead of Alarm, 24 VDC is ordered on Alarm 1 terminals, Alarm 2 should also be 24 VDC
0 None
1 4..20 mA Retransmission Output
2 Isolated 4..20 mA Retransmission output
E Communication 3 RS 485
4 Serial Printer Port
5 Isolated 24V/ 30mA, 2 wire Transmitter Power Supply
9 Special

1 85 to 265 VAC
F Power Supply 2 20...32 V DC
9 Special

ACCESSORIES (For Models with Independent Alarms)


1) Weather proof Enclosure for DIN Rail Mounted Alarm Output Card with 16 / 32 Open Collector outputs
2) External Relay Box For Scanners with Independent Alarms
- weatherproof enclosure housing DIN rail mounted Open collector output card, Power supply & Relay
Module/s. Power Supply : 230 V AC, 50 Hz
Note : Item No. 1 not required
a) Relay Box with 8 Nos. Alarm Relay 3 Amps/250 V AC
b) Relay Box with 16 Nos. Alarm Relay 3 Amps/250 V AC
c) Relay Box with 32 Nos. Alarm Relay 3 Amps/250 V AC (for 16 Channel Scanner only)

Envada Electric Power Engineering Technology Co. Ltd.,


1, Rangemore Hall Mews, Rangemore,
Burton upon Trent, Staffordshire, DE13 9RE, UK
Tel: +44 1283 716400 Fax: +44 1283 716417 E-mail: [email protected]

Distributor: Local Contact:


Toshniwal Industries Pvt. Ltd.
Industrial Estate, Makhupura,
Ajmer – 305 002 (India)
Tel: 2695171, 2695205; Fax: (0145)2695174
E-mail: [email protected] ; Web: www.tipl.com

You might also like