Two Way Slab
Two Way Slab
Design Constants :
fy = 276 MPa
fc' = 28 MPa
rg = 0.002 Dead Loads :
rmax = 0.04097 Floor Finish = 1.10 kPa
rmin = 0.00580 Restroom = 1.10 kPa
m = 7.91966 Ceiling = 0.15 kPa
Movable Partition = 1.00 kPa
Unit Weight of = 24 kN/m3
Reinforced Concrete Live Loads :
Assume Beam width = 0.300 m Basic Floor Area = 4.80 kPa
Restroom = 4.80 kPa
Slab Thickness :
Typical Floors = 130 mm
Conc. Cover = 20 mm All Floors :
Smax (Long Direction) = 260 mm
Bar Diameters : Smax (Short Direction) = 260 mm
Long Direction = 10 mm Eff. d (Long Direction) = 95 mm
Short Direction = 10 mm Eff. d (Short Direction) = 95 mm
Positive Moments
m 0.9 0.95 0.917
Ca,pos. dl 0.022 0.02 0.02133 Ma,pos. dl = 4.159 kN
Cb,pos. dl 0.014 0.016 0.01467 Ma,pos. ll = 7.589 kN
Ca,pos. ll 0.034 0.03 0.03267 Ma,pos. Total = 11.748 kN
Cb,pos. ll 0.022 0.025 0.02300 Mb,pos. dl = 3.402 kN
Mb,pos. ll = 6.359 kN
Negative Moments at Discontinuous edge Mb,pos. Total = 9.761 kN
Ma,neg = 0.000 kN
Mb,neg = 0.000 kN
Positive Moments
m 0.75 0.8 0.767
Ca,pos. dl 0.048 0.045 0.04700 Ma,pos. dl = 6.409 kN
Cb,pos. dl 0.012 0.015 0.01300 Ma,pos. ll = 8.721 kN
Ca,pos. ll 0.055 0.051 0.05367 Ma,pos. Total = 15.130 kN
Cb,pos. ll 0.016 0.019 0.01700 Mb,pos. dl = 3.016 kN
Mb,pos. ll = 4.700 kN
Negative Moments at Discontinuous edge Mb,pos. Total = 7.716 kN
Ma,neg = 5.043 kN
Mb,neg = 2.572 kN