The document provides sizing calculations for a steam condensate pot. It includes input data such as the condensate flow rate, density, reboiler orientation and dimensions. The calculations determine the reboiler pressure drop, condensate line pressure drop, reboiler bottom to pot height, reboiler back flooding height, total pot height, condensate volumetric flow, pot cross sectional area, calculated and selected pot diameters, and minimum difference for indicating on a PID. A diagram illustrates the key dimensions of the condensate pot.

Uploaded by

maniazhar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
285 views1 page

Steam Condensate Pot Sizing

The document provides sizing calculations for a steam condensate pot. It includes input data such as the condensate flow rate, density, reboiler orientation and dimensions. The calculations determine the reboiler pressure drop, condensate line pressure drop, reboiler bottom to pot height, reboiler back flooding height, total pot height, condensate volumetric flow, pot cross sectional area, calculated and selected pot diameters, and minimum difference for indicating on a PID. A diagram illustrates the key dimensions of the condensate pot.

Uploaded by

maniazhar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

PROJECT : DATE : 23-Apr-11

PROJ. NO.: BY : S. Rahimi


CLIENT: REV : A
UNIT : DOC NO.:

Steam Condensate Pot Sizing

Input Data
Vessel Tag No. V-5103
Vessel Service Cond. Pot
Condensate Flow Rate kg/hr 1811
Flow Rate Overdesign % 20
Condensate Density kg/m3 810.7
Reboiler Orientation ---- Horizontal
Reboiler bundle Pressure Drop bar 0.01
Reboiler Turndown Operation % 30
Condensate Line Pressure drop bar/100m 0.0035
Condensate Line Length m 20
Rebolier Bundle Diameter mm 725
Pot BTM TL - LLLL Height mm 150
Pot LLLL - LLL Height mm 188
Pot Hold up time (LLL - NLL) min 1
Pot Hold up time (NLL - HLL) min 1.5
Pot HLL - TOP TL mm 300

Calculation Results
Reboiler Pressure drop mm 93
Condensate Line Pressure Drop bar 0.001
Condensate Line Pressure Drop mm 9
Reobiler bottom to Pot NLL mm 102
Reboiler Back Flooding Height mm 507.5
Pot Total Height mm 1700
S
Span Length
L th (LLL - HLL) mm 609
Condensate Volumetric Flow 3 3.4
m /hr
Pot Cross Sectional Area m2 0.23
Pot Caculated Diameter mm 540
Pot Selected Diameter mm 550
Pot LLL to NLL mm 235
Min ∆X (for indicating on PID) mm 675

Steam

HHLL 1400
HLL 1183

508
1700 mm
550
102 LC
NLL 573
∆X
LLL 338
LLLL 150
0

Condensate

Notes

www.chemwork.org