1719 Ex I/O

New Intrinsically Safe Distributed I/O by Rockwell Automation

1719 Ex I/O is an intrinsically safe distributed I/O platform that can be mounted in
Zone 2 or Class I, Div 2 and integrates devices in hazardous areas via EtherNet/IP.
Tight integration with Integrated Architecture allows easy configuration and a
compact, chassis-based I/O design provides maximum efficiency in a small space.

Features and Benefits


Intrinsically Safe I/O to Satisfy Compact, Chassis-based I/O Design
Application Requirements
• Power Supply is contained on the chassis
• 1719 is certified for Zone 2 or Class I, • Maximum efficiency in small space
Div 2 Mounting

Tight Integration with Integrated Architecture Additional Product Features


for Easy Configuration • DLR Adapter and Optional Power
Supply Redundancy
• Connect on EtherNet/IP
• HART 7 support standard on all
• Add-On Profile support in RSLogix 5000 v24
analog modules
and above
1719 Ex I/O
New Intrinsically Safe Distributed I/O by Rockwell Automation

Chassis Dimension

EtherNet I/P EtherNet I/P


1719-A8

113 mm

275 mm

1719-A22

113 mm

605 mm

1719-A24 (Expansion Chassis)

113 mm

605 mm
1719 Ex I/O
New Intrinsically Safe Distributed I/O by Rockwell Automation

Zone 2 or Class I, Div 2 I/O Modules Accessories Environmental Specifications


Catalog Number Description Catalog Number Description Ambient temperature -20°C to +60°C (-4°F to +140°F)
1719-CF4H 4-channel HART analog configurable 1719-PSDC DC power supply Storage temperature -25°C to +85°C (-13°F to +185°F)
1719-IF4HB 4-channel HART analog input wide 1719-A8 8 slot base chassis Relative humidity 95% non-condensing acc. to EN 60068-2-78:2001
1719-IF4H* 4-channel HART analog input 1719-A22 22 slot base chassis Shock resistance Shock type I, Shock duration 11 ms, Shock amplitude 5g, Num-
ber of shock directions 6, Number of shocks per direction 100
1719-IR4B 4-channel RTD input 1719-A24 24 slot extension chassis
acc. To EN 60068-2-27:2009
1719-IT4B 4-channel thermocouple input 1719-TB8 8 pole screw terminal
Vibration resistance Frequency range 5 ... 500 Hz, Amplitude 5 ... 13.2Hz ± 1.5 mm,
1719-IRT4* 4-channel thermocouple RTD input 1719-TB8S 8 pole spring terminal 13.2 ... 100 Hz 1g, Sweep rate 1 octave/min, Duration 10 sweeps
1719-IBN8B 8 Point digital input NAMUR wide 5 Hz - 100 Hz -5Hz acc. to EN 60068-2-6:2008
1719-TB8x2 2x8 pole screw terminal
1719-IBN8* 8 Point digital Input NAMUR Damaging gas For plugs: 21 days in 25 ppm SO2, at 25°C and 75% rel. humid-
1719-TB8Sx2 2x8 pole spring terminal
ity, Device G3 acc. to EN 60068-2-42:2003
1719-OB2 2 Point digital output 23V 1719-TB6 6 pole screw terminal
Certifications Zone 2 or Class 1,Div 2, ATEX, IECEx, UL/c-UL, CE, C-Tick/RCM,
1719-OB2L 2 Point digital output 16.5V 1719-TB6S 6 pole spring terminal Marine, Custom Union (EAC)
1719-IJ Frequency counter 1719-CBL Chassis extension cable 1m
* Availability in 2017 1719-ARM Empty slot cover

See 1719 Ex I/O Specifications and Technical Data at:


http://ab.rockwellautomation.com/IO/In-Cabinet-Modular/1719-Ex-IO

Allen-Bradley, Compact I/O CompactLogix, Studio 5000 and Rockwell Software are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation® are property of their respective companies.
EtherNet/IP is a trademark of ODVA, Inc.

Publication 1719-PP001A-EN-P – October 2016 Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved.

You might also like